Microsecond lifetime-based optical carbon dioxide sensor using luminescence resonance energy transfer

Abstract A lifetime-based optical sensor for the measurement of dissolved and gaseous carbon dioxide has been developed. The basic principle is radiationless energy transfer from ruthenium(II)-4,4′-diphenyl-2,2′-bipyridyl as luminescent donor to thymol blue (a common pH indicator) as acceptor, both embedded in a hydrophobic matrix. In the presence of carbon dioxide thymol blue is protonated and changes its color from blue to yellow resulting in a decrease in the rate of energy transfer and consequently an increase in decay time. The decay time as a p CO 2 -dependent parameter was measured in the frequency domain with a blue light emitting diode as a light source modulated at 75 kHz. The present sensor displays a phase shift up to 16° in the range 0–30 hPa of p CO 2 corresponding to a change in decay time from 0.38 to 1.05 μs. The detection limit was found to be 0.5 μM (22 ppb) of dissolved carbon dioxide and the response times are of the order of 15 s when going from 0 to 30 hPa p CO 2 . The temperature behavior of the sensor has been studied in detail and a linear relationship Arrhenius plot has been found. The effect of molecular oxygen as a potential quencher of the luminescence was investigated in detail. The carbon dioxide sensor is stable over weeks, and is robust.

[1]  David R. Walt,et al.  A fiber-optic sensor for CO2 measurement , 1988 .

[2]  D. Walt,et al.  Multiple-indicator fiber-optic sensor for high-resolution pCO2 sea water measurements , 1993 .

[3]  Chemically and mechanically resistant carbon dioxide optrode based on a covalently immobilized pH indicator , 1993 .

[4]  B. Weigl,et al.  New hydrophobic materials for optical carbon dioxide sensors based on ion pairing , 1995 .

[5]  Christian Huber,et al.  Energy transfer-based lifetime sensing of chloride using a luminescent transition metal complex , 1998 .

[6]  I Klimant,et al.  Optical triple sensor for measuring pH, oxygen and carbon dioxide. , 1994, Journal of biotechnology.

[7]  R. Byrne,et al.  Determination of sea water alkalinity by direct equilibration with carbon dioxide , 1992 .

[8]  H Szmacinski,et al.  Optical measurements of pH using fluorescence lifetimes and phase-modulation fluorometry. , 1993, Analytical chemistry.

[9]  Ingo Klimant,et al.  Oxygen-Sensitive Luminescent Materials Based on Silicone-Soluble Ruthenium Diimine Complexes , 1995 .

[10]  Andrew Mills,et al.  Equilibrium studies on colorimetric plastic film sensors for carbon dioxide , 1992 .

[11]  Joseph R. Lakowicz,et al.  Phase Fluorometric Optical Carbon Dioxide Gas Sensor for Fermentation Off‐Gas Monitoring , 1996, Biotechnology progress.

[12]  O. Wolfbeis,et al.  Ammonia-sensitive polymer matrix employing immobilized indicator ion pairs , 1995 .

[13]  J R Lakowicz,et al.  A lifetime-based optical CO2 gas sensor with blue or red excitation and stokes or anti-stokes detection. , 1995, Analytical biochemistry.

[14]  P. Brewer,et al.  Development of a fiber optic sensor for measurement of pCO2 in sea water: design criteria and sea trials , 1992 .

[15]  Andrew Mills,et al.  Fluorescence plastic thin-film sensor for carbon dioxide , 1993 .

[16]  L. Merlivat,et al.  A new optical sensor for PCO2 measurements in seawater , 1993 .

[17]  Joseph R Lakowicz,et al.  Phase Fluorometry Using a Continuously Modulated Laser Diode. , 1992, Analytical chemistry.