Partial Discharge Testing under Direct Voltage Conditions
暂无分享,去创建一个
DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelarated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.
[1] A. I. Bennett. Frequency dependence of partial discharges, and measurement of void content in insulation , 1974 .
[2] R. Densley,et al. Partial discharges under direct-voltage conditions , 1979 .
[3] B. Salvage,et al. Discharge detection and measurement under direct-voltage conditions: significance of discharge magnitude , 1965 .