Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence.

OBJECTIVES The aim of this study was to assess prosthesis/annulus discongruence and its impact on the occurrence of significant aortic regurgitation (AR) immediately after transcatheter aortic valve implantation (TAVI). BACKGROUND Paravalvular AR might occur after TAVI, but its determinants remain unclear. METHODS Comprehensive echocardiographic examinations were performed in 74 patients who underwent TAVI with a balloon expandable device. Congruence between annulus and device was appraised with the cover index: 100 x (prosthesis diameter - transesophageal echocardiography annulus diameter)/prosthesis diameter. RESULTS At baseline aortic valve area was 0.67 +/- 0.2 cm(2), and mean gradient was 50 +/- 15 mm Hg. The TAVI used transfemoral approach in 46 patients (62%) and transapical access in 28 (38%). Prosthesis size was 23 mm in 24 patients (34%) and 26 mm in 50 patients (66%). After TAVI, paravalvular AR was absent in 5 patients (7%), graded 1/4 in 53 (72%), 2/4 in 12 (16%), and 3/4 in 4 (5%). Occurrence of AR >or=2/4 was related to greater patient height, larger annulus, and smaller cover index (all p < 0.002) but not to ejection fraction, severity of stenosis, or prosthesis size. AR >or=2/4 was never observed in patients with aortic annulus <22 mm or with a cover index >8%. Significant improvements were observed from the first 20 cases (AR >or=2/4, 40%) to the last 54 (AR >or=2/4, 15%) (p = 0.02). In multivariate analysis, independent predictors of AR >/=2/4 were low cover index (odds ratio: 1.22; per confidence interval: 1.03 to 1.51 per 1% decrease, p = 0.02) and first versus last procedures (odds ratio: 2.24; 95% confidence interval: 1.07 to 5.22, p = 0.03). CONCLUSIONS Our study shows that the occurrence of AR >or=2/4 is related to prosthesis/annulus discongruence even after adjustment for experience. Hence, to minimize paravalvular AR, appropriate annular measurements and prosthesis sizing are critical.

[1]  Assaf Bash,et al.  Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis: First Human Case Description , 2002, Circulation.

[2]  N. Reichek,et al.  Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. , 1989, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[3]  Y. Castier,et al.  Contemporary surgical or percutaneous management of severe aortic stenosis in the elderly. , 2008, European heart journal.

[4]  M. Cheitlin Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery , 2007 .

[5]  A P Yoganathan,et al.  Doppler color flow mapping in the evaluation of prosthetic mitral and aortic valve function. , 1989, Journal of the American College of Cardiology.

[6]  A. Cheung,et al.  Transapical aortic valve implantation in humans. , 2006, The Journal of thoracic and cardiovascular surgery.

[7]  Ghassan Sleilaty,et al.  Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults. , 2008, Journal of the American College of Cardiology.

[8]  A. Cheung,et al.  Six-month outcome of transapical transcatheter aortic valve implantation in the initial seven patients. , 2007, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[9]  J. Webb,et al.  Transcatheter percutaneous and transapical aortic valve replacement. , 2007, Seminars in thoracic and cardiovascular surgery.

[10]  N. Al-Attar,et al.  Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). , 2008, European heart journal.

[11]  Lukas Altwegg,et al.  Percutaneous Transarterial Aortic Valve Replacement in Selected High-Risk Patients With Aortic Stenosis , 2007, Circulation.

[12]  P. Serruys,et al.  Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. , 2008, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[13]  Thomas Walther,et al.  Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. , 2007, Journal of the American College of Cardiology.

[14]  Thomas Felderhoff,et al.  Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease: The Siegburg First-in-Man Study , 2006 .

[15]  Mirko Doss,et al.  Transapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience , 2007, Circulation.

[16]  Assaf Bash,et al.  Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis. , 2004, Journal of the American College of Cardiology.

[17]  A. Fraser,et al.  Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography , 2003, Heart.

[18]  P. Nihoyannopoulos,et al.  Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up. , 1999, American heart journal.

[19]  P. Pibarot,et al.  Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. , 2000, Journal of the American College of Cardiology.

[20]  A. Vahanian,et al.  Transcatheter valve implantation for patients with aortic stenosis , 2010, Heart.

[21]  D. Malenka,et al.  Outcome of mild periprosthetic regurgitation detected by intraoperative transesophageal echocardiography. , 2001, Journal of the American College of Cardiology.

[22]  A. Cribier,et al.  Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. , 2006, Journal of the American College of Cardiology.

[23]  S. Rahimtoola,et al.  The problem of valve prosthesis-patient mismatch. , 1978, Circulation.

[24]  R. Moss,et al.  Role of echocardiography in percutaneous aortic valve implantation. , 2008, JACC. Cardiovascular imaging.

[25]  G. Filippatos,et al.  [Guidelines on the management of valvular heart disease]. , 2013, Revista espanola de cardiologia.

[26]  Helmut Baumgartner,et al.  Guidelines on the management of valvular heart disease The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology , 2007 .

[27]  Anson Cheung,et al.  Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience , 2006, Circulation.

[28]  R. Levine,et al.  Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. , 2003, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[29]  P. Pibarot,et al.  Prosthesis-patient mismatch: definition, clinical impact, and prevention , 2005, Heart.

[30]  A J Tajik,et al.  Prediction of the severity of aortic stenosis by Doppler aortic valve area determination: prospective Doppler-catheterization correlation in 100 patients. , 1988, Journal of the American College of Cardiology.

[31]  Volkmar Falk,et al.  Minimally invasive transapical beating heart aortic valve implantation--proof of concept. , 2007, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[32]  A. Stillman,et al.  Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size? , 2008, JACC. Cardiovascular interventions.