An air-assisted liquid–liquid extraction using a dual-valve sequential injection manifold (DV-SIA): Determination of copper

This work introduces an approach to liquid–liquid extraction for the sequential injection technique by improving on a previously reported dual-valve sequential injection manifold (DV-SIA). The system is made up of three units: a Mixing unit (for aqueous phase only), an Extraction unit, and a Detection unit (for organic phase only). The extraction was carried out by controlled aeration in the Extraction unit. The efficiency of the suggested extraction procedure was demonstrated by the spectrophotometric determination of copper extracted as an ion associate of Cu(I) with the polymethine dye 1,3,3-trimethyl-2-[5-(1,3,3-trimethyl-1,3-dihydroindol-2-ylidene)-penta-1,3-dienyl]-3H-indolium (DIDC). Appropriate experimental conditions were found to be: 40 μL of 2 mol L−1 NaCl; 50 μL of sample, 20 μL of 1 mmol L−1 DIDC (pH 3), flow rate 50 μL s−1. A linear response was obtained in the range 0.13–2.0 μg mL−1 of Cu, and the limit of detection, calculated based on three times the standard deviation of the blank test (n = 10), was 0.02 μg mL−1. The method was applied to an assay of copper in pharmaceutical materials.

[1]  V. Cerdà,et al.  Reversed flow injection and sandwich sequential injection methods for the spectrophotometric determination of copper(II) with cuprizone , 2003 .

[2]  E. Hansen,et al.  Sequential injection on-line matrix removal and trace metal preconcentration using a PTFE beads packed column as demonstrated for the determination of cadmium by electrothermal atomic absorption spectrometry , 2002 .

[3]  Saisunee Liawruangrath,et al.  The development of sequential injection analysis coupled with lab-on-valve for copper determination. , 2006, Talanta.

[4]  K. Toda,et al.  A gas-phase chemiluminescence-based analyzer for waterborne arsenic. , 2006, Analytical chemistry.

[5]  K. Grudpan,et al.  Novel approach for mono-segmented flow micro-titration with sequential injection using a lab-on-valve system: a model study for the assay of acidity in fruit juices. , 2005, The Analyst.

[6]  J. Peñuelas,et al.  Determination of As, Cd, Cu, Hg and Pb in biological samples by modern electrothermal atomic absorption spectrometry , 2010 .

[7]  T. Horiuchi,et al.  ppb-Level detection of benzene diluted in water with portable device based on bubbling extraction and UV spectroscopy , 2008 .

[8]  D. Arrigan,et al.  Determination of trace metals by underpotential deposition–stripping voltammetry at solid electrodes , 2005 .

[9]  J. Pawliszyn,et al.  A critical review in calibration methods for solid-phase microextraction. , 2008, Analytica chimica acta.

[10]  Janusz Pawliszyn,et al.  Recent developments in solid-phase microextraction , 2009, Analytical and bioanalytical chemistry.

[11]  A. Anthemidis,et al.  On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples. , 2009, Talanta.

[12]  Y. Bazel,et al.  An investigation of the reaction of copper ions with dimethylindodicarbocyanine dye: an application for the determination of Cu(I), Cu(II) and Cu(III). , 2008, Talanta.

[13]  J. V. van Staden,et al.  Determination of Lead(II), Copper(II), Zinc(II), Cobalt(II), Cadmium(II), Iron(III), Mercury(II) using sequential injection extractions. , 2004, Talanta.

[14]  M. Miró,et al.  Application of flowing stream techniques to water analysis Part III. Metal ions: alkaline and alkaline-earth metals, elemental and harmful transition metals, and multielemental analysis. , 2004, Talanta.

[15]  Jianhua Wang,et al.  Coupling on-line preconcentration by ion-exchange with ETAAS: A novel flow injection approach based on the use of a renewable microcolumn as demonstrated for the determination of nickel in environmental and biological samples , 2000 .

[16]  W. B. Neto,et al.  Determination of manganese and nickel in slurry sampling by graphite furnace atomic absorption spectrometry , 2008 .

[17]  T. Prasada Rao,et al.  Application of ternary and multicomponent complexes to spectrophotometric and spectrofluorimetric analysis of inorganics. , 1998, Talanta.

[18]  Peter C. Hauser,et al.  Trace-metal analysis with separation methods , 2005 .

[19]  E. Hansen,et al.  Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry , 2002 .

[20]  Petr Solich,et al.  A novel dual-valve sequential injection manifold (DV-SIA) for automated liquid-liquid extraction. Application for the determination of picric acid. , 2010, Analytica chimica acta.

[21]  A. Amin Utilization of solid phase spectrophotometry for the determination of trace amounts of copper using 5-(2-benzothiazolylazo)-8-hydroxyquinoline , 2009 .

[22]  Jun‐Jie Zhu,et al.  Ultrasensitive Cu2+ sensing by near-infrared-emitting CdSeTe alloyed quantum dots. , 2010, Talanta.

[23]  Francisco Pena-Pereira,et al.  Miniaturized preconcentration methods based on liquid–liquid extraction and their application in inorganic ultratrace analysis and speciation: A review , 2009 .

[24]  J. Pawliszyn,et al.  Solid phase microextraction with thermal desorption using fused silica optical fibers , 1990 .

[25]  N. Teshima,et al.  Sequential injection lab-on-valve simultaneous spectrophotometric determination of trace amounts of copper and iron. , 2006, Talanta.

[26]  Vitor C. Almeida,et al.  Exploiting the bead injection concept for sequential determination of copper and mercury ions in river-water samples. , 2004, Talanta.