Analysis of Underfrequency Load Shedding Using a Frequency Gradient

Underfrequency load shedding is one of the most important protection systems, as in many cases it represents the last chance to prevent a system blackout after a serious disturbance occurs in a power system. In order to improve traditional schemes, many efforts have been concentrated on attempts to use the frequency gradient as an indicator for determining the lack of active power in a system. This paper concentrates on analyzing the factors that influence the gradient. Analyses have shown that the gradient can give misleading information about the active-power deficit, as long as certain factors are ignored or assumed to be constant. A draft of a gradient-based underfrequency load-shedding scheme is presented, which also highlights the problems associated with the use of gradient. On the one hand, a frequency gradient alone does not appear to be sufficient for the active-power deficit estimation. Nevertheless, for the actual load-shedding procedure it is found to be very useful.

[1]  T.J. Overbye,et al.  Line Outage Detection Using Phasor Angle Measurements , 2008, IEEE Transactions on Power Systems.

[2]  Zexiang Cai,et al.  A method for frequency dynamics analysis and load shedding assessment based on the trajectory of power system simulation , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[3]  M. Etezadi-Amoli On underfrequency load shedding schemes , 1990, Proceedings of the Twenty-Second Annual North American Power Symposium.

[4]  P. M. Anderson,et al.  A low-order system frequency response model , 1990 .

[5]  G. L. Wilson,et al.  Frequency Actuated Load Shedding and Restoration Part I - Philosophy , 1971 .

[6]  Wang Xin A new load shedding scheme for limiting underfrequency , 2002 .

[7]  Shyh-Jier Huang,et al.  An adaptive load shedding method with time-based design for isolated power systems , 2000 .

[8]  J. Machowski Power System Dynamics And Stability , 1997 .

[9]  Chen-Ching Liu,et al.  AN INTELLIGENT ADAPTIVE LOAD SHEDDING SCHEME , 2002 .

[10]  F. Silvestro,et al.  Implementation and comparison of different under frequency load-shedding schemes , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[11]  S. S. Venkata,et al.  An adaptive approach to load shedding and spinning reserve control during underfrequency conditions , 1996 .

[12]  H. E. Lokay,et al.  Application of Underfrequency Relays for Automatic Load Shedding , 1968 .

[13]  Xiaorong Xie,et al.  WAMS-based Load Shedding for Systems Suffering Power Deficit , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[14]  V. Terzija,et al.  Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation , 2006, IEEE Transactions on Power Systems.

[15]  P. M. Anderson,et al.  An adaptive method for setting underfrequency load shedding relays , 1992 .

[16]  H. Seyedi,et al.  New Centralized Adaptive Under Frequency Load Shedding Algorithms , 2007, 2007 Large Engineering Systems Conference on Power Engineering.

[17]  C. Concordia,et al.  Load shedding on an isolated system , 1995 .