Chronic in vivo stability assessment of carbon fiber microelectrode arrays

OBJECTIVE Individual carbon fiber microelectrodes can record unit activity in both acute and semi-chronic (∼1 month) implants. Additionally, new methods have been developed to insert a 16 channel array of carbon fiber microelectrodes. Before assessing the in vivo long-term viability of these arrays, accelerated soak tests were carried out to determine the most stable site coating material. Next, a multi-animal, multi-month, chronic implantation study was carried out with carbon fiber microelectrode arrays and silicon electrodes. APPROACH Carbon fibers were first functionalized with one of two different formulations of PEDOT and subjected to accelerated aging in a heated water bath. After determining the best PEDOT formula to use, carbon fiber arrays were chronically implanted in rat motor cortex. Some rodents were also implanted with a single silicon electrode, while others received both. At the end of the study a subset of animals were perfused and the brain tissue sliced. Tissue sections were stained for astrocytes, microglia, and neurons. The local reactive responses were assessed using qualitative and quantitative methods. MAIN RESULTS Electrophysiology recordings showed the carbon fibers detecting unit activity for at least 3 months with average amplitudes of ∼200 μV. Histology analysis showed the carbon fiber arrays with a minimal to non-existent glial scarring response with no adverse effects on neuronal density. Silicon electrodes showed large glial scarring that impacted neuronal counts. SIGNIFICANCE This study has validated the use of carbon fiber microelectrode arrays as a chronic neural recording technology. These electrodes have demonstrated the ability to detect single units with high amplitude over 3 months, and show the potential to record for even longer periods. In addition, the minimal reactive response should hold stable indefinitely, as any response by the immune system may reach a steady state after 12 weeks.

[1]  Huanan Zhang,et al.  Nanostructured Coatings for Improved Charge Delivery to Neurons , 2014 .

[2]  Matthew D. Johnson,et al.  Spatiotemporal pH dynamics following insertion of neural microelectrode arrays , 2007, Journal of Neuroscience Methods.

[3]  Zhanhong Du,et al.  Comprehensive chronic laminar single-unit, multi-unit, and local field potential recording performance with planar single shank electrode arrays , 2015, Journal of Neuroscience Methods.

[4]  J. Assad,et al.  Nanotechnology and neuroscience : nano-electronic, photonic and mechanical neuronal interfacing , 2014 .

[5]  D. S. Freedman,et al.  Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cord , 2015, Journal of neural engineering.

[6]  Paras R. Patel,et al.  Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces. , 2012, Nature materials.

[7]  Justin C. Sanchez,et al.  Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing , 2012, Journal of neural engineering.

[8]  G. Paxinos,et al.  The Rat Brain in Stereotaxic Coordinates , 1983 .

[9]  Matthew A. Wilson,et al.  Hippocampal Replay of Extended Experience , 2009, Neuron.

[10]  David C. Martin,et al.  Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film , 2006, Journal of neural engineering.

[11]  Andrew S. Whitford,et al.  Cortical control of a prosthetic arm for self-feeding , 2008, Nature.

[12]  Andrew B. Schwartz,et al.  Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics , 2006, Neuron.

[13]  D W L Hukins,et al.  Accelerated aging for testing polymeric biomaterials and medical devices. , 2008, Medical engineering & physics.

[14]  David M. Santucci,et al.  Learning to Control a Brain–Machine Interface for Reaching and Grasping by Primates , 2003, PLoS biology.

[15]  Seong-Gi Kim,et al.  In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes , 2012, Journal of neural engineering.

[16]  David C. Martin,et al.  Electrochemical deposition and characterization of poly(3,4-ethylenedioxythiophene) on neural microelectrode arrays , 2003 .

[17]  D. Szarowski,et al.  Brain responses to micro-machined silicon devices , 2003, Brain Research.

[18]  X Liu,et al.  Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[19]  Garrett B Stanley,et al.  The impact of chronic blood-brain barrier breach on intracortical electrode function. , 2013, Biomaterials.

[20]  Gordon G Wallace,et al.  Conducting polymer coated neural recording electrodes , 2013, Journal of neural engineering.

[21]  Daryl R Kipke,et al.  An alginate hydrogel dura mater replacement for use with intracortical electrodes. , 2010, Journal of biomedical materials research. Part B, Applied biomaterials.

[22]  J M Carmena,et al.  In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[23]  G. J. Maclay,et al.  Preparation and characterization of platinum black electrodes , 2000 .

[24]  Vikash Gilja,et al.  Long-term Stability of Neural Prosthetic Control Signals from Silicon Cortical Arrays in Rhesus Macaque Motor Cortex , 2010 .

[25]  Hamid Charkhkar,et al.  Improving the performance of poly(3,4-ethylenedioxythiophene) for brain-machine interface applications. , 2014, Acta biomaterialia.

[26]  R. R. Carter,et al.  Multiple single-unit recordings from the CNS using thin-film electrode arrays , 1993 .

[27]  David C. Martin,et al.  Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays , 2005, Experimental Neurology.

[28]  R. Normann,et al.  A method for pneumatically inserting an array of penetrating electrodes into cortical tissue , 2006, Annals of Biomedical Engineering.

[29]  Patrick A Tresco,et al.  Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays. , 2011, Progress in brain research.

[30]  Daryl R. Kipke,et al.  Optimization of Microelectrode Design for Cortical Recording Based on Thermal Noise Considerations , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[31]  A. Levey,et al.  Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration , 2009, Journal of neural engineering.

[32]  G. Buzsáki,et al.  Distinct Representations and Theta Dynamics in Dorsal and Ventral Hippocampus , 2010, The Journal of Neuroscience.

[33]  X Tracy Cui,et al.  Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response. , 2014, Biomaterials.

[34]  Nicolas Y. Masse,et al.  Reach and grasp by people with tetraplegia using a neurally controlled robotic arm , 2012, Nature.

[35]  Huanan Zhang,et al.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings , 2015, Journal of neural engineering.

[36]  Patrick A Tresco,et al.  Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex. , 2010, Biomaterials.

[37]  F. Solzbacher,et al.  In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays , 2010, Biomedical materials.

[38]  Nigel H Lovell,et al.  Substrate dependent stability of conducting polymer coatings on medical electrodes. , 2012, Biomaterials.

[39]  D R Kipke,et al.  Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping , 2010, Journal of neural engineering.

[40]  Daryl R. Kipke,et al.  Use of a Bayesian maximum-likelihood classifier to generate training data for brain-machine interfaces (Journal of Neural Engineering (2011) 8) , 2011 .

[41]  James D. Weiland,et al.  Electrochemical Characterization of Charge Injection at Electrodeposited Platinum Electrodes in Phosphate Buffered Saline , 2006 .

[42]  Justin C. Williams,et al.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.

[43]  K. Horch,et al.  Biocompatibility of silicon-based electrode arrays implanted in feline cortical tissue. , 1993, Journal of biomedical materials research.

[44]  Michael J. Black,et al.  Neural control of cursor trajectory and click by a human with tetraplegia 1000 days after implant of an intracortical microelectrode array , 2011 .

[45]  Daryl R Kipke,et al.  Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants , 2007, Journal of neural engineering.

[46]  Euisik Yoon,et al.  Chronic In Vivo Evaluation of PEDOT/CNT for Stable Neural Recordings , 2016, IEEE Transactions on Biomedical Engineering.

[47]  J. Muthuswamy,et al.  Thin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex , 2007, Journal of neural engineering.

[48]  Daryl R Kipke,et al.  Theoretical analysis of intracortical microelectrode recordings , 2011, Journal of neural engineering.

[49]  Justin C. Sanchez,et al.  Electrode impedance analysis of chronic tungsten microwire neural implants: understanding abiotic vs. biotic contributions , 2014, Front. Neuroeng..

[50]  D. Kipke,et al.  Neural probe design for reduced tissue encapsulation in CNS. , 2007, Biomaterials.

[51]  A. Michael,et al.  Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies , 2014, ACS chemical neuroscience.

[52]  James D. Weiland,et al.  Electrochemical Deposition of Platinum from Aqueous Ammonium Hexachloroplatinate Solution , 2005 .

[53]  Michael D Joseph,et al.  Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes , 2011, Journal of neural engineering.

[54]  D.M. Taylor,et al.  Information conveyed through brain-control: cursor versus robot , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[55]  R. L. Rennakera,et al.  A comparison of chronic multi-channel cortical implantation techniques : manual versus mechanical insertion , 2005 .

[56]  Kelsey A. Potter,et al.  Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses , 2012, Journal of neural engineering.

[57]  R. Bellamkonda,et al.  The effect of inflammatory cell-derived MCP-1 loss on neuronal survival during chronic neuroinflammation. , 2014, Biomaterials.

[58]  R. L. Rennaker,et al.  A comparison of chronic multi-channel cortical implantation techniques: manual versus mechanical insertion , 2005, Journal of Neuroscience Methods.

[59]  Steve M. Potter,et al.  Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black , 2010, Front. Neuroeng..

[60]  C. Robertson,et al.  Reactive mononuclear phagocytes release neurotoxins after ischemic and traumatic injury to the central nervous system , 1993, Journal of neuroscience research.

[61]  Anne E Carpenter,et al.  Neuron-type specific signals for reward and punishment in the ventral tegmental area , 2011, Nature.

[62]  A. Schwartz,et al.  High-performance neuroprosthetic control by an individual with tetraplegia , 2013, The Lancet.

[63]  Karen L. Smith,et al.  Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion , 2006, Journal of neural engineering.

[64]  David J. Anderson,et al.  Electrochemical deposition and characterization of conducting polymer polypyrrole/PSS on multichannel neural probes , 2001 .

[65]  O. B. Ozdoganlar,et al.  Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes. , 2014, Biomaterials.

[66]  Patrick Ruther,et al.  Short and long term biocompatibility of NeuroProbes silicon probes , 2010, Journal of Neuroscience Methods.

[67]  H. Eichenbaum,et al.  Striatal versus hippocampal representations during win-stay maze performance. , 2009, Journal of neurophysiology.

[68]  D. Szarowski,et al.  Cerebral Astrocyte Response to Micromachined Silicon Implants , 1999, Experimental Neurology.

[69]  Patrick A Tresco,et al.  The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull. , 2007, Journal of biomedical materials research. Part A.

[70]  D. Edell,et al.  Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex , 1992, IEEE Transactions on Biomedical Engineering.

[71]  Kasey Catt,et al.  Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording. , 2015, Biomaterials.

[72]  R. Wightman,et al.  Conical tungsten tips as substrates for the preparation of ultramicroelectrodes. , 2006, Langmuir : the ACS journal of surfaces and colloids.

[73]  David E Thompson,et al.  Data-driven model comparing the effects of glial scarring and interface interactions on chronic neural recordings in non-human primates , 2016, Journal of neural engineering.

[74]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[75]  S.F. Cogan,et al.  Electrodeposited iridium oxide for neural stimulation and recording electrodes , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[76]  P. Tresco,et al.  Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.

[77]  Alberto Paleari,et al.  Glycine-Spacers Influence Functional Motifs Exposure and Self-Assembling Propensity of Functionalized Substrates Tailored for Neural Stem Cell Cultures , 2009, Front. Neuroeng..