Advances in two‐dimensional GC with glass capillary columns

A versatile two-dimensional gas chromatograph is described, consisting of 2 separate ovens, one intermediate trap, an auxiliary inlet, and the necessary hardware to effect off-line switching according to the principle of Deans. The unit has been designed for use with high resolution glass capillary columns. The performance of individual instrumental components was critically evaluated. Results showed that low dead volume glass to metal connections were required in the manifold and detector lines to minimize extra-column effects. The mass of the intermediate trap must be low to allow rapid heating. Operational parameters are discussed and examples of some applications are shown.

[1]  Roger J. Miller,et al.  The application of flow switching rotary valves in two-dimensional high resolution gas chromatography , 1979 .

[2]  R. Kaiser,et al.  Change of polarity by temperature variation of series‐coupled micropacked GC columns, measured in retention index data , 1978 .

[3]  V. Pretorius,et al.  Rapid evaporation of condensed gas chromatographic fractions , 1978 .

[4]  V. Pretorius,et al.  Control of relative retention in gas chromatography by temperature variation of series‐coupled columns , 1978 .

[5]  W. Bertsch Methods in high resolution gas chromatography. Two-dimensional techniques , 1978 .

[6]  W. Bertsch,et al.  Practical aspects of Pt/Ir effluent splitters for multidetector GC and pneumatic solute switching , 1978 .

[7]  K. Grob On-column injection on to glass capillary columns , 1978 .

[8]  G. Schomburg,et al.  New developments and experiences with glass capillary column production and sampling techniques , 1977 .

[9]  W. Halang,et al.  Simultaneous three-dimensional gas-liquid chromatography on wall-coated glass-capillary columns , 1977 .

[10]  F. Müller,et al.  Experience and problems with capillary glass columns in process chromatography , 1977 .

[11]  W. Jennings,et al.  WCOT glass capillary columns in flavour chemistry , 1977 .

[12]  W. Bertsch,et al.  Two-dimensional high resolution GLC environmental analysis, preliminary results , 1977 .

[13]  R. Kaiser The correct measurement and interpretation of evaluation factors in chromatography: The real plate number, the separation number, the dosage quality. Part 1: Gas chromatography , 1977 .

[14]  K. Grob,et al.  A new, generally applicable procedure for the preparation of glass capillary columns , 1976 .

[15]  G. Schomburg,et al.  Aspects of double-column gas chromatography with glass capillaries involving intermediate trapping , 1975 .

[16]  R. E. Kaiser Trenncassetten zur Gas-Chromatographie Ein neues technisches System zur Erleichterung normaler und extrem schwieriger Analysen, besonders in der Umwelt-Analytik , 1974 .

[17]  K. Grob,et al.  Isothermal analysis on capillary columns without stream splitting , 1974 .

[18]  R. Freeman,et al.  Determination of .DELTA.9-tetrahydrocannabinol in blood by electron capture gas chromatography , 1973 .

[19]  K. Grob,et al.  Trace analysis on capillary columns. Selected practical applications: insecticides in raw butter extract; aroma head space from liquors; auto exhaust gas. , 1970 .

[20]  D. R. Deans A new technique for heart cutting in gas chromatography [1] , 1968 .

[21]  P. A. Schenck,et al.  Two-stage capillary gas chromatography. , 1967, Analytica chimica acta.