Doppler echocardiography in cardiac tamponade: exaggerated respiratory variation in transvalvular blood flow velocity integrals.

Pulsed Doppler echocardiography has been used previously to demonstrate marked changes in transvalvular blood flow velocities during cardiac tamponade in laboratory animals and a small number of patients. To further assess the respiratory changes in transvalvular blood flow during tamponade, pulsed Doppler tracings of flow velocity profiles across all four cardiac valves were recorded during inspiration and expiration in 13 patients during cardiac tamponade, in 6 of the 13 patients after relief of tamponade by pericardiocentesis and in 8 normal control subjects. Flow velocity integrals were calculated for each valve during inspiration and expiration. In the setting of cardiac tamponade, inspiration caused an 85 +/- 46% increase in the flow velocity integral across the pulmonary valve, an 81 +/- 34% increase across the tricuspid valve, a 33 +/- 13% decrease across the aortic valve and a 35 +/- 8% decrease across the mitral valve. These phasic respiratory changes were markedly reduced after relief of tamponade (p less than 0.05 compared with tamponade) and were observed to only a minimal extent in the normal individuals (p less than 0.01 compared with tamponade). The exaggerated respiratory variations in transvalvular flow velocity integrals suggest that Doppler evaluation may be a valuable tool in the diagnosis of cardiac tamponade. Transmitral Doppler indexes of left ventricular filling during cardiac tamponade revealed that inspiration caused a shift to increased filling during late diastole, with a greater contribution of atrial systole to total left ventricular filling. These Doppler indexes did not vary significantly with respiration in the group studied after relief of tamponade or in the control group.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  E. Botvinick,et al.  Right Ventricular Compression as a Sign of Cardiac Tamponade: An Analysis of Echocardiographic Ventricular Dimensions and Their Clinical Implications , 1977, Circulation.

[2]  I. D'cruz,et al.  Diagnosis of Cardiac Tamponade by Echocardiography: Changes in Mitral Valve Motion and Ventricular Dimensions, With Special Reference to Paradoxical Pulse , 1975, Circulation.

[3]  C. Higgins,et al.  The pericardium and cardiac function. , 1979, Progress in cardiovascular diseases.

[4]  Fowler No Physiology of cardiac tamponade and pulsus paradoxus. I: mechanisms of pulsus paradoxus in cardiac tamponade. , 1978 .

[5]  W. Guntheroth,et al.  Effect of Respiration on Venous Return and Stroke Volume in Cardiac Tamponade: Mechanism Of Pulsus Paradoxus , 1967, Circulation research.

[6]  S. Gidding,et al.  Left ventricular diastolic filling in children with hypertrophic cardiomyopathy: assessment with pulsed Doppler echocardiography. , 1986, Journal of the American College of Cardiology.

[7]  H. S. Klopfenstein,et al.  Effects of intravascular volume state on the value of pulsus paradoxus and right ventricular diastolic collapse in predicting cardiac tamponade. , 1985, Circulation.

[8]  L L Huntsman,et al.  Noninvasive Doppler Determination of Cardiac Output in Man: Clinical Validation , 1983, Circulation.

[9]  R. Adolph,et al.  Echocardiographic Study of the Paradoxical Arterial Pulse in Chronic Obstructive Lung Disease , 1980, Circulation.

[10]  D J Sahn,et al.  Doppler-detected paradoxus of mitral and tricuspid valve flows in chronic lung disease. , 1986, Journal of the American College of Cardiology.

[11]  F. Cosío,et al.  Abnormal septal motion in cardiac tamponande with pulse paradoxus. Echocardiographic and hemodynamic observations. , 1977, Chest.

[12]  J. Ross,et al.  Effect of respiration on venous return and stroke volume in cardiac tamponade , 1970, British heart journal.

[13]  Daniel E. Guyer,et al.  Hydrodynamic compression of the right atrium: a new echocardiographic sign of cardiac tamponade. , 1983, Circulation.

[14]  R. Whalen,et al.  Pressure and volume changes of the left ventricle in acute pericardial tamponade. , 1968, The American journal of cardiology.

[15]  K. Kensey,et al.  Two-dimensional echocardiography in cardiac tamponade occurring after cardiac surgery. , 1985, Journal of the American College of Cardiology.

[16]  M C Limacher,et al.  Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. , 1984, Circulation.

[17]  M. Mcgregor Current concepts: pulsus paradoxus. , 1979, The New England journal of medicine.

[18]  J. Greenfield,et al.  Pressure‐Flow Studies in Man: Effect of Respiration on Left Ventricular Stroke Volume , 1973, Circulation.

[19]  N. Fowler,et al.  The hemodynamics of cardiac tamponade and constrictive pericarditis. , 1970, The American journal of cardiology.

[20]  N. S. Agruss,et al.  Echocardiographic Study of Cardiac Tamponade , 1977, Circulation.

[21]  A. Tajik,et al.  Noninvasive measurement of cardiac output by continuous-wave Doppler echocardiography: initial experience and review of the literature. , 1984, Mayo Clinic proceedings.

[22]  H. Friedman,et al.  Pulsus paradoxus: a manifestation of a marked reduction of left ventricular end-diastolic volume in cardiac tamponade. , 1980, The Journal of thoracic and cardiovascular surgery.

[23]  K. Miyatake,et al.  Augmentation of atrial contribution to left ventricular inflow with aging as assessed by intracardiac Doppler flowmetry. , 1984, The American journal of cardiology.

[24]  J. Tanouchi,et al.  Transmitral blood flow reflecting diastolic behavior of the left ventricle in health and disease--a study by pulsed Doppler technique. , 1982, Japanese circulation journal.

[25]  J. Roelandt,et al.  Limits of reproducibility of blood flow measurements by Doppler echocardiography. , 1987, The American journal of cardiology.