Influence of low order harmonic phase angles on tripping time of overcurrent relays

Experimental analyses are used to investigate the impact of low order harmonics on the operation and tripping times of overcurrent relays. Two analytical approaches based on relay characteristics provided by the manufacturer and simulations using PSCAD software package are used to estimate tripping times under non-sinusoidal operating conditions. Experiments were conducted such that the order, magnitude and phase angle of harmonics could be controlled by employing a computer-based single-phase harmonic source. Computed and measured tripping times are compared and suggestions on the application of overcurrent relays in harmonically polluted environments are provided.

[1]  Ward Jewell,et al.  Effects of harmonics on equipment , 1993 .

[2]  Ewald F. Fuchs,et al.  Impact of nonlinear loads on anisotropic transformers , 1991 .

[3]  M.A.S. Masoum,et al.  Impact of harmonics on tripping time of overcurrent relays , 2007, 2007 Australasian Universities Power Engineering Conference.

[4]  R.A. Rob,et al.  Computer based harmonic simulation and testing for microprocessor-based phase distance relay with phase locator , 1993, Conference Record Industrial and Commercial Power Systems Technical Conference 1993.

[5]  G. T. Heydt,et al.  Power Quality Engineering , 2001, IEEE Power Engineering Review.

[6]  Mohammad A. S. Masoum,et al.  Power Quality in Power Systems and Electrical Machines , 2008 .

[7]  A. K. Khan Monitoring power for the future , 2001 .

[8]  C. Sankaran Power Quality , 2001 .

[9]  Surya Santoso,et al.  Understanding Power System Hannonics , 2001, IEEE Power Engineering Review.

[10]  S.E. Zocholl,et al.  Effect of waveform distortion on protective relays , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[11]  W.E. Kazibwe,et al.  Power quality: a review , 1990, IEEE Computer Applications in Power.

[12]  Ewald F. Fuchs,et al.  Influence of harmonics on power distribution system protection , 1988 .

[13]  Ewald F. Fuchs,et al.  Are harmonic recommendations according to IEEE and IEC too restrictive , 2004 .

[14]  S. Perera,et al.  Power quality (PQ) survey reporting: discrete disturbance limits , 2005, IEEE Transactions on Power Delivery.

[15]  A.A. Girgis,et al.  Effect of voltage harmonics on the operation of solid state relays in industrial applications , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.