Current image acquisition options in PET/MR.

Whole-body PET/MR hybrid imaging combines excellent soft tissue contrast and various functional imaging parameters provided by MR with high sensitivity and quantification of radiotracer uptake provided by PET. Although clinical evaluation now is under way, PET/MR demands for new technologies and innovative solutions, currently subject to interdisciplinary research. Attenuation correction (AC) of human soft tissues and of hardware components has to be MR based to maintain quantification of PET imaging as CT attenuation information is missing. MR-based AC is inherently associated with the following challenges: patient tissues are segmented into only few tissue classes, providing discrete attenuation coefficients; bone is substituted as soft tissue in MR-based AC; the limited field of view in MRI leads to truncations in body imaging and, consequently, in MR-based AC; and correct segmentation of lung tissue may be hampered by breathing artifacts. Use of time of flight during PET image acquisition and reconstruction, however, may improve the accuracy of AC. This article provides a status of current image acquisition options in PET/MR hybrid imaging.

[1]  Patrick Dupont,et al.  Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms , 1999, IEEE Transactions on Medical Imaging.

[2]  G. M. Bydder,et al.  MRI of the brain with ultra-short echo-time pulse sequences , 2003, Neuroradiology.

[3]  D. Townsend,et al.  Method for transforming CT images for attenuation correction in PET/CT imaging. , 2006, Medical physics.

[4]  Ciprian Catana,et al.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  Christoph Palm,et al.  MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[6]  B. Schölkopf,et al.  Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[7]  R. S. Hinks,et al.  A multispectral three‐dimensional acquisition technique for imaging near metal implants , 2009, Magnetic resonance in medicine.

[8]  F. Beekman,et al.  A novel, SiPM-array-based, monolithic scintillator detector for PET , 2009, Physics in medicine and biology.

[9]  V. Schulz,et al.  MR-based attenuation correction for a whole-body sequential PET/MR system , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[10]  Nassir Navab,et al.  Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data , 2009, Journal of Nuclear Medicine.

[11]  Johan Nuyts,et al.  Completion of a truncated attenuation image from the attenuated PET emission data , 2013, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[12]  Axel Martinez-Möller,et al.  Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner , 2010, Physics in medicine and biology.

[13]  R. Günther,et al.  Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[14]  Ciprian Catana,et al.  Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype , 2010, The Journal of Nuclear Medicine.

[15]  D. Townsend,et al.  An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT Imaging , 2010, Journal of Nuclear Medicine.

[16]  S. Vandenberghe,et al.  MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences , 2010, Journal of Nuclear Medicine.

[17]  Gaspar Delso,et al.  The effect of limited MR field of view in MR/PET attenuation correction. , 2010, Medical physics.

[18]  R. Holen,et al.  The effect of errors in segmented attenuation maps on PET quantification. , 2011, Medical physics.

[19]  Adam Johansson,et al.  CT substitute derived from MRI sequences with ultrashort echo time. , 2011, Medical physics.

[20]  H. Zaidi,et al.  Design and performance evaluation of a whole-body Ingenuity TF PET–MRI system , 2011, Physics in medicine and biology.

[21]  G. Delso,et al.  Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner , 2011, The Journal of Nuclear Medicine.

[22]  Til Aach,et al.  Simultaneous Reconstruction of Activity and Attenuation for PET/MR , 2011, IEEE Transactions on Medical Imaging.

[23]  D. Mankoff,et al.  Impact of Time-of-Flight PET on Whole-Body Oncologic Studies: A Human Observer Lesion Detection and Localization Study , 2011, The Journal of Nuclear Medicine.

[24]  Ilja Bezrukov,et al.  MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods , 2011, The Journal of Nuclear Medicine.

[25]  F. Hofheinz,et al.  Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction , 2012, Magnetic Resonance Materials in Physics, Biology and Medicine.

[26]  Jean Théberge,et al.  Variable Lung Density Consideration in Attenuation Correction of Whole-Body PET/MRI , 2012, The Journal of Nuclear Medicine.

[27]  C. Kuhl,et al.  MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence , 2012, The Journal of Nuclear Medicine.

[28]  M. Defrise,et al.  Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET , 2012, IEEE Transactions on Medical Imaging.

[29]  Jae Sung Lee,et al.  Comparison of Segmentation-Based Attenuation Correction Methods for PET/MRI: Evaluation of Bone and Liver Standardized Uptake Value with Oncologic PET/CT Data , 2012, The Journal of Nuclear Medicine.

[30]  Peter M Jakob,et al.  Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA) , 2012, Magnetic resonance in medicine.

[31]  Sune H. Keller,et al.  Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[32]  A. Ahmadian,et al.  MRI-guided attenuation correction in whole-body PET/MR: assessment of the effect of bone attenuation , 2013, Annals of Nuclear Medicine.

[33]  Harald H Quick,et al.  Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils. , 2012, Medical physics.

[34]  T. Beyer,et al.  Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[35]  I. Burger,et al.  PET/MR imaging of bone lesions – implications for PET quantification from imperfect attenuation correction , 2012, European Journal of Nuclear Medicine and Molecular Imaging.

[36]  Adam Johansson,et al.  Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[37]  M. Defrise,et al.  Time-of-flight PET data determine the attenuation sinogram up to a constant , 2012, Physics in medicine and biology.

[38]  Hamidreza Saligheh Rad,et al.  Comparison of optimized soft‐tissue suppression schemes for ultrashort echo time MRI , 2012, Magnetic resonance in medicine.

[39]  Thomas Beyer,et al.  PET/MR imaging of the pelvis in the presence of endoprostheses: reducing image artifacts and increasing accuracy through inpainting , 2013, European Journal of Nuclear Medicine and Molecular Imaging.

[40]  M. Nittka,et al.  Reduction of metal artifacts in patients with total hip arthroplasty with slice-encoding metal artifact correction and view-angle tilting MR imaging. , 2012, Radiology.

[41]  Jin-Suck Suh,et al.  Usefulness of slice encoding for metal artifact correction (SEMAC) for reducing metallic artifacts in 3-T MRI. , 2013, Magnetic resonance imaging.

[42]  H. Quick,et al.  Magnetic Resonance–Based Attenuation Correction for PET/MR Hybrid Imaging Using Continuous Valued Attenuation Maps , 2013, Investigative radiology.

[43]  Craig S. Levin,et al.  Prototype time-of-flight PET ring integrated with a 3T MRI system for simultaneous whole-body PET/MR imaging , 2013 .

[44]  K. Scheffler,et al.  MR‐based field‐of‐view extension in MR/PET: B0 homogenization using gradient enhancement (HUGE) , 2013, Magnetic resonance in medicine.

[45]  G Antoch,et al.  Positron emission tomography (PET) attenuation correction artefacts in PET/CT and PET/MRI. , 2013, The British journal of radiology.

[46]  Harald H Quick,et al.  Integrated PET/MR imaging: automatic attenuation correction of flexible RF coils. , 2013, Medical physics.

[47]  R. Boellaard,et al.  Accurate PET/MR Quantification Using Time of Flight MLAA Image Reconstruction , 2014, Molecular Imaging and Biology.

[48]  B. Schölkopf,et al.  MR-Based PET attenuation correction for PET/MR imaging. , 2013, Seminars in nuclear medicine.

[49]  H. Quick,et al.  Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging. , 2014, Medical physics.

[50]  Grace Parraga,et al.  Ultra‐short echo‐time pulmonary MRI: Evaluation and reproducibility in COPD subjects with and without bronchiectasis , 2015, Journal of magnetic resonance imaging : JMRI.