Implantable electrical left ventricular assist system: bridge to transplantation and the future.

An implantable left ventricular assist system (LVAS) utilizing an electromechanically driven dual pusher-plate blood pump has been employed in a multiinstitutional trial as a bridge to cardiac transplantation. Under development for permanent circulatory support in patients with end-stage heart disease, the LVAS, in this application, derives power and control from an external console via a percutaneous lead. The LVAS was implanted in 20 patients (16 men, 4 women) who were hemodynamically unstable or in refractory cardiogenic shock. The mean age was 44.9 years (range, 25 to 63 years). Preoperative diagnosis was evenly divided between end-stage ischemic disease, cardiomyopathy, and acute myocardial infarction. Implanted in the left upper quadrant within the anterior abdominal wall, the blood pump was connected between the left ventricular apex and ascending aorta. Total support of the systemic circulation and substantial left ventricular unloading were achieved with synchronous counterpulsation for periods up to 90 days (mean, 22.7 days). All patients were stabilized hemodynamically. The mean preoperative cardiac index of 1.5 L/min/m2 increased by a factor of 2. Pulmonary arterial pressures decreased substantially. Serious complications occurred in 16 patients, precluding cardiac transplantation in 10. Most complications (greater than 70%) were in patients who did not receive transplants; the most common complication was bleeding. Twelve of 13 patients with LVAS implants for more than seven days were mobilized, and 4 were fully ambulatory and completely rehabilitated. Orthotopic cardiac transplantation was performed in 10 patients after implants ranging from two to 90 days (mean, 30.3 days).(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  Joist Jh,et al.  Platelet reactions with artificial surfaces. , 1987 .

[2]  J. Copeland,et al.  The role of mechanical support and transplantation in treatment of patients with end-stage cardiomyopathy. , 1985, Circulation.

[3]  W S Pierce,et al.  Mechanical support of the circulation followed by cardiac transplantation. , 1986, The Journal of thoracic and cardiovascular surgery.

[4]  W. Dobelle,et al.  Cardiac transplantation for patients requiring mechanical circulatory support. , 1978, The New England journal of medicine.

[5]  J. Magovern,et al.  The Importance of a Patent Foramen Ovale in Left Ventricular Assist Pumping , 1986, ASAIO transactions.

[6]  N. Shumway,et al.  Studies on orthotopic homotransplantation of the canine heart. , 1960, Surgical forum.

[7]  W. Baumgartner,et al.  Present expectations in cardiac transplantation. , 1987, The Annals of thoracic surgery.

[8]  B. Griffith,et al.  Cardiac Transplantation , 1986, The Annals of thoracic surgery.

[9]  Kaye Mp,et al.  The Registry of the International Society for Heart Transplantation: fourth official report--1987. , 1987, Clinical transplants.

[10]  J. C. Norman,et al.  TOTAL SUPPORT OF THE CIRCULATION OF A PATIENT WITH POST-CARDIOTOMY STONE-HEART SYNDROME BY A PARTIAL ARTIFICIAL HEART (ALVAD) FOR 5 DAYS FOLLOWED BY HEART AND KIDNEY TRANSPLANTATION , 1978, The Lancet.

[11]  K. Affeld,et al.  Assisted Circulation 2 , 1984, Springer Berlin Heidelberg.

[12]  R L Kormos,et al.  Temporary use of the Jarvik-7 total artificial heart before transplantation. , 1987, The New England journal of medicine.

[13]  P M Portner,et al.  Isolated left ventricular assist as bridge to cardiac transplantation. , 1988, The Journal of thoracic and cardiovascular surgery.

[14]  J. Copeland,et al.  The Total Artificial Heart as a Bridge to Transplantation: A Report of Two Cases , 1986 .

[15]  D. Pennington,et al.  Bridging to cardiac transplantation with pulsatile ventricular assist devices. , 1988, The Annals of thoracic surgery.

[16]  The permanent artificial heart. Four case reports. , 1988 .

[17]  W. Pae,et al.  Temporary left ventricular assistance in acute myocardial infarction and cardiogenic shock: rationale and criteria for utilization. , 1981, Chest.

[18]  D. Pennington,et al.  Renal failure in patients with ventricular assist devices. , 1987, ASAIO transactions.

[19]  G L Hallman,et al.  Orthotopic cardiac prosthesis for two-staged cardiac replacement. , 1969, The American journal of cardiology.

[20]  P M Portner,et al.  In vitro and in vivo testing of a totally implantable left ventricular assist system. , 1988, ASAIO transactions.

[21]  R L Kormos,et al.  The artificial heart: infection-related morbidity and its effect on transplantation. , 1988, The Annals of thoracic surgery.

[22]  M. Rubenfire,et al.  Current Status of Intraaortic Balloon Pump and Initial Clinical Experience with Aortic Patch Mechanical Auxiliary Ventricle , 1971 .

[23]  B. Griffith,et al.  Summary of the world experience with clinical use of total artificial hearts as heart support devices. , 1986, The Journal of heart transplantation.

[24]  L. Rice,et al.  Artificial heart implantation: what limitations are imposed by infectious complications? , 1988, JAMA.

[25]  A. Pavie,et al.  Total artificial heart as a bridge for transplantation: La Pitié 1986 to 1987 , 1988 .

[26]  I. Chalmers Letter: Obstetric Delivery Today. , 1976, Lancet.

[27]  W. Pae,et al.  Ventricular-assist pumping in patients with cardiogenic shock after cardiac operations. , 1981, The New England journal of medicine.

[28]  M E DeBakey,et al.  Left ventricular bypass pump for cardiac assistance. Clinical experience. , 1971, The American journal of cardiology.

[29]  W S Pierce,et al.  Heterotopic prosthetic ventricles as a bridge to cardiac transplantation. A multicenter study in 29 patients. , 1988, The New England journal of medicine.