Evaluating Quality and Utility of Digital Mammograms and Lossy Compressed Digital Mammograms

C. N. Adams, M.S.a, A. Aiyer, M.S.a, B.J. Betts, M.S.a, J. Li, M.S.a, P. C. Cosman, Ph.D.,b S. M. Perlmutter, Ph.D.,c M. Williams, Ph.D.,d K. O. Perlmutter, Ph.D.c, D. Ikeda, M.D.,e L. Fajardo, M.D.d, R. Birdwell, M.D.e, B. L. Daniel, M.D.e, S. Rossiter, M.D.e, R. A. Olshen, Ph.D.,f and R. M. Gray, Ph.D.a aInformation Systems Laboratory, Department of Electrical Engineering, Stanford University, Stanford, CA bDepartment of Electrical and Computer Engineering, University of California at San Diego, La Jolla, CA cJohnson-Grace Company, Inc., 2 Corporate Plaza, Suite 150, Newport Beach, CA dDepartment of Radiology, University of Virginia, Charlottesville, VA eDepartment of Radiology, Stanford University, Stanford, CA fDepartments of Health Research and Policy, Statistics, and Electrical Engineering, Stanford University, Stanford CA.

[1]  R A Olshen,et al.  Thoracic CT images: effect of lossy image compression on diagnostic accuracy. , 1994, Radiology.

[2]  P. Holland,et al.  Discrete Multivariate Analysis. , 1976 .

[3]  Pamela C. Cosman,et al.  Measurement accuracy as a measure of image quality in compressed MR chest scans , 1994, Proceedings of 1st International Conference on Image Processing.

[4]  Pamela C. Cosman,et al.  Evaluating quality of compressed medical images: SNR, subjective rating, and diagnostic accuracy , 1994, Proc. IEEE.

[5]  R.M. Gray,et al.  Evaluating quality and utility in digital mammography , 1995, Proceedings., International Conference on Image Processing.

[6]  D. Chakraborty,et al.  Free-response methodology: alternate analysis and a new observer-performance experiment. , 1990, Radiology.

[7]  J. Hanley,et al.  The meaning and use of the area under a receiver operating characteristic (ROC) curve. , 1982, Radiology.

[8]  Heping Zhang,et al.  Predicting high-risk cholesterol levels , 1994 .

[9]  William A. Pearlman,et al.  A new, fast, and efficient image codec based on set partitioning in hierarchical trees , 1996, IEEE Trans. Circuits Syst. Video Technol..

[10]  Pamela C. Cosman,et al.  Tree-structured vector quantization of CT chest scans: image quality and diagnostic accuracy , 1993, IEEE Trans. Medical Imaging.

[11]  J. Swets ROC analysis applied to the evaluation of medical imaging techniques. , 1979, Investigative radiology.

[12]  J. Hanley,et al.  Statistical Approaches to the Analysis of Receiver Operating Characteristic (ROC) Curves , 1984, Medical decision making : an international journal of the Society for Medical Decision Making.

[13]  Jacob Cohen,et al.  Weighted kappa: Nominal scale agreement provision for scaled disagreement or partial credit. , 1968 .