Performance of a nonlinear hybrid base isolation system under the ground motions

Abstract In order to reduce the displacement demand of the isolation layer under strong earthquakes, especially strong near fault pulse-like ground motions, the base isolation system-tuned mass damper inerter (BIS-TMDI) system is explored taking the nonlinear hysteretic characteristics of the isolation layer into inclusion. Likewise, different from traditional layout of the BIS-TMDI systems, the TMD is placed on the superstructure (such as first floor or third floor, etc.) rather than on the isolation layer and linked to the ground by an inerter. By resorting to the equivalent linearization method (ELM) and genetic algorithm (GA) optimization, the optimal design method of nonlinear BIS-TMDI system is established and then, the performance of the system is numerically investigated. Results demonstrate that the nonlinear BIS-TMDI system can significantly reduce the displacement demand of the isolation layer, and its control effectiveness and stroke performance are better than those of the nonlinear BIS-TMD system. The influences of the parameters of the superstructure, isolation layer, and earthquake ground motions on the vibration mitigation is further scrutinized. It follows that the robustness of nonlinear BIS-TMDI system is much better than that of nonlinear BIS-TMD system. Analyzing the nonlinear BIS-TMDI system subjected to the near-fault pulse-like ground motions, the superiority of the system in reducing the displacement of isolation layer, the responses of superstructure and the stroke performance of TMDI are further verified.

[1]  Agathoklis Giaralis,et al.  Optimal design of a novel tuned mass-damper–inerter (TMDI) passive vibration control configuration for stochastically support-excited structural systems , 2014 .

[2]  Liyuan Cao,et al.  Tuned tandem mass dampers‐inerters with broadband high effectiveness for structures under white noise base excitations , 2019, Structural Control and Health Monitoring.

[3]  Kohei Fujita,et al.  The 2011 off the Pacific coast of Tohoku earthquake and response of high-rise buildings under long-period ground motions , 2011 .

[4]  James M. Kelly,et al.  Base Isolation: Linear Theory and Design , 1990 .

[5]  Zheng Lu,et al.  Study on self‐adjustable tuned mass damper with variable mass , 2018 .

[6]  P. Brzeski,et al.  Novel type of tuned mass damper with inerter which enables changes of inertance , 2015 .

[7]  Masato Saitoh,et al.  On the performance of gyro‐mass devices for displacement mitigation in base isolation systems , 2012 .

[8]  Yinlong Hu,et al.  Load mitigation for a barge-type floating offshore wind turbine via inerter-based passive structural control , 2018, Engineering Structures.

[9]  Salvatore Perno,et al.  Dynamic response and optimal design of structures with large mass ratio TMD , 2012 .

[10]  D. De Domenico,et al.  Soil-dependent optimum design of a new passive vibration control system combining seismic base isolation with tuned inerter damper , 2018 .

[11]  B. F. Spencer,et al.  STATE OF THE ART OF STRUCTURAL CONTROL , 2003 .

[12]  Mohammed Ismail,et al.  The Hysteresis Bouc-Wen Model, a Survey , 2009 .

[13]  M. De Angelis,et al.  Optimal design and performance evaluation of systems with Tuned Mass Damper Inerter (TMDI) , 2017 .

[14]  R. S. Jangid,et al.  Stochastic response of building frames isolated by lead–rubber bearings , 2010 .

[15]  S C Liu,et al.  Aseismic Hybrid Control Systems for Building Structures , 1991 .

[16]  Roger M. Goodall,et al.  Passive suspensions incorporating inerters for railway vehicles , 2012 .

[17]  Long Chen,et al.  Improved design of dynamic vibration absorber by using the inerter and its application in vehicle suspension , 2016 .

[18]  Luigi Petti,et al.  Response of base isolated systems equipped with tuned mass dampers to random excitations , 1997 .

[19]  Izuru Takewaki,et al.  Resonant behaviour of base‐isolated high‐rise buildings under long‐period ground motions , 2006 .

[20]  Agathoklis Giaralis,et al.  Optimal tuning and assessment of inertial dampers with grounded inerter for vibration control of seismically excited base-isolated systems , 2019, Engineering Structures.

[21]  Vasant Matsagar,et al.  Along‐wind response control of chimneys with distributed multiple tuned mass dampers , 2018, Structural Control and Health Monitoring.

[22]  Liang Hu,et al.  Analytical solution of seismic response of base‐isolated structure with supplemental inerter , 2019, Earthquake Engineering & Structural Dynamics.

[24]  Malcolm C. Smith Synthesis of mechanical networks: the inerter , 2002, IEEE Trans. Autom. Control..

[25]  F. Sun,et al.  Performance evaluation of existing isolated buildings with supplemental passive pseudo-negative stiffness devices , 2018, Engineering Structures.

[26]  Michele Zilletti,et al.  Feedback control unit with an inerter proof-mass electrodynamic actuator , 2016 .

[27]  R. S. Jangid,et al.  Base isolation for near‐fault motions , 2001 .

[28]  Ruifu Zhang,et al.  Mitigation of liquid sloshing in storage tanks by using a hybrid control method , 2016 .

[29]  Anna Reggio,et al.  Optimal energy‐based seismic design of non‐conventional Tuned Mass Damper (TMD) implemented via inter‐story isolation , 2015 .

[30]  Armen Der Kiureghian,et al.  Effect of tuned mass damper on displacement demand of base-isolated structures , 2008 .

[31]  D. De Domenico,et al.  An enhanced base isolation system equipped with optimal tuned mass damper inerter (TMDI) , 2018 .

[32]  Cenk Alhan,et al.  Performance limits of seismically isolated buildings under near-field earthquakes , 2016 .

[33]  Diego Lopez-Garcia,et al.  Optimization of height-wise damper distributions considering practical design issues , 2018, Engineering Structures.

[34]  Zheng Lu,et al.  Experimental parametric study on wind‐induced vibration control of particle tuned mass damper on a benchmark high‐rise building , 2017 .

[35]  H. Tajimi,et al.  Statistical Method of Determining the Maximum Response of Building Structure During an Earthquake , 1960 .

[36]  K. Thiele,et al.  Tuned mass dampers in wind response control of wind turbine with soil-structure interaction , 2020 .

[37]  R. S. Jangid Optimum lead–rubber isolation bearings for near-fault motions , 2007 .

[38]  Mehmet Çelebi,et al.  Design of Seismic Isolated Structures: From Theory to Practice , 2000 .

[39]  Liyuan Cao,et al.  Performance of multiple tuned mass dampers-inerters for structures under harmonic ground acceleration , 2020 .

[40]  Kohju Ikago,et al.  Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper , 2012 .