Masimo Signal Extraction Pulse Oximetry

Objective.To describe a new pulse oximetry technology and measurement paradigm developed by Masimo Corporation.Introduction.Patient motion, poor tissue perfusion, excessive ambient light, and electrosurgical unit interference reduce conventional pulse oximeter (CPO) measurement integrity. Patient motion frequently generates erroneous pulse oximetry values for saturation and pulse rate. Motion-induced measurement error is due in part to wide spread implementation of a theoretical pulse oximetry model which assumes that arterial blood is the only light-absorbing pulsatile component in the optical path. Methods.Masimo Signal Extraction Technology(SET®) pulse oximetry begins with conventional red and infrared photoplethysmographic signals, and then employs a constellation of advanced techniques including radiofrequency and light-shielded optical sensors, digital signal processing, and adaptive filtration, to measure SpO2 accurately during challenging clinical conditions. In contrast to CPO which calculates O2 saturation from the ratio of transmitted pulsatile red and infrared light, Masimo SET pulse oximetry uses a new conceptual model of light absorption for pulse oximetry and employs the discrete saturation transform (DST) to isolate individual “saturation components” in the optical pathway. Typically, when the tissue under analysis is stationary, only the single saturation component produced by pulsatile arterial blood is present.In contrast, during patient motion, movement of non-arterial components (for example, venous blood) can be identified as additional saturation components (with a lower O2 saturation). When conditions of the Masimo model are met, the saturation component corresponding to the highest O2 saturation is reported by the instrument as SpO2. Conclusion.The technological strategies implemented in Masimo SET pulse oximetry effectively permit continuous monitoring of SpO2 during challenging clinical conditions of motion and poor tissue perfusion.

[1]  Bernard Widrow,et al.  Adaptive Signal Processing , 1985 .

[2]  J. Severinghaus,et al.  History of blood gas analysis. , 1987, International anesthesiology clinics.

[3]  M. Wukitsch,et al.  Pulse oximetry: Analysis of theory, technology, and practice , 1988, Journal of Clinical Monitoring.

[4]  S. Wilson Conscious sedation and pulse oximetry: false alarms? , 1990, Pediatric dentistry.

[5]  D. Bourke,et al.  Digital nerve blocks can restore pulse oximeter signal detection. , 1991, Anesthesia and analgesia.

[6]  B. Chraemmer-jørgensen,et al.  Randomized Evaluation of Pulse Oximetry in 20,802 Patients; I: Design, Demography, Pulse Oximetry Failure Rate, and Overall Complication Rate , 1993, Anesthesiology.

[7]  K. Holroyd,et al.  Intraarterial vasodilator administration to restore pulse oximeter function. , 1993, Anesthesiology.

[8]  S. Lawless Crying wolf: False alarms in a pediatric intensive care unit , 1994, Critical care medicine.

[9]  N. Gravenstein,et al.  Pulse Oximetry Monitoring Can Change Routine Oxygen Supplementation Practices in the Postanesthesia Care Unit , 1994, Anesthesia and analgesia.

[10]  P. Pan,et al.  Intraoperative pulse oximetry: frequency and distribution of discrepant data. , 1994, Journal of clinical anesthesia.

[11]  Carlson Ka,et al.  An update on pulse oximetry. Part II: limitations and future applications. , 1994 .

[12]  B Hök,et al.  Postanesthesia monitoring revisited: frequency of true and false alarms from different monitoring devices. , 1994, Journal of clinical anesthesia.

[13]  E M Bosque,et al.  Symbiosis of nurse and machine through fuzzy logic: improved specificity of a neonatal pulse oximeter alarm. , 1995, ANS. Advances in nursing science.

[14]  K. Tremper,et al.  Clinical Evaluation of a Prototype Motion Artifact Resistant Pulse Oximeter in the Recovery Room , 1996, Anesthesia and analgesia.

[15]  D. Reich,et al.  Predictors of Pulse Oximetry Data Failure , 1996, Anesthesiology.

[16]  Steven J. Barker,et al.  The effects of motion on the performance of pulse oximeters in volunteers (revised publication). , 1997 .

[17]  C. Tsien,et al.  Poor prognosis for existing monitors in the intensive care unit. , 1997, Critical care medicine.

[18]  Steven J. Barker,et al.  The performance of three pulse oximeters during low perfusion in volunteers , 1997 .

[19]  S. Barker,et al.  Effects of motion, ambient light, and hypoperfusion on pulse oximeter function , 1997 .

[20]  Ehud Zmora,et al.  Nurses' response to alarms from monitoring systems in NICU. 1027 , 1997, Pediatric Research.

[21]  M. Goldstein,et al.  Conventional Pulse Oximetry Can Give Spurious Data in a Neonatal Population at Risk for Retinopathy of Prematurity (ROP) † 1260 , 1998, Pediatric Research.

[22]  E. Gangitano,et al.  Near Continuous Pulse Oximetry During Newborn ECLS , 1999 .

[23]  K. A. Hale,et al.  Pulse Oximetry in the NICU: Conventional Vs Masimo SET , 1999 .

[24]  N. Gravenstein,et al.  Continuous neonatal evaluation in the delivery room by pulse oximetry , 1987, Journal of Clinical Monitoring.

[25]  J. Eichhorn Pulse Oximetry Monitoring and Late Postoperative Hypoxemia on the General Care Floor , 2004, Journal of Clinical Monitoring and Computing.

[26]  Cor J. Kalkman,et al.  Influence of Pulse Oximeter Settings on the Frequency of Alarms and Detection of Hypoxemia , 1998, Journal of Clinical Monitoring and Computing.

[27]  John W. Severinghaus,et al.  History of blood gas analysis. VII. Pulse oximetry , 1987, Journal of Clinical Monitoring.

[28]  Karen L. Posner,et al.  A prospective study of intraoperative pulse oximetry failure , 1991, Journal of Clinical Monitoring.