External fixation versus locked intramedullary nailing in tibial shaft fractures: a prospective, randomised study of 78 patients

IntroductionWe performed a prospective, randomised study to compare the Ex-fi-re external fixator (EF) with locked intramedullary (IM) nailing in tibial fractures. Only fractures without soft-tissue problems of importance were included.Materials and methodsEx-fi-re is a unilateral, dynamic axial fixator with fracture reduction capabilities. The Grosse-Kempf nail was used for nailing. A total of 78 patients with 79 fractures were entered in the study (41 Ex-fi-re, 38 IM nails).ResultsTime to radiographic union and full weight-bearing did not differ significantly, but unprotected weight-bearing was achieved earlier in the IM group (12 vs 20 weeks; p<0.001). There were more reoperations due to secondary dislocation in the EF group. There were no differences in final angulation or shortening. After 6 months and 1 year there were no differences in knee motion, ankle motion, fracture site pain or ankle pain. Some 64% of the nailed patients complained of anterior knee pain after 1 year.ConclusionThe results were comparable in most respects. Unprotected weight-bearing was achieved earlier after IM nailing. Anterior knee pain was frequent after nailing.

[1]  C. Court-Brown,et al.  External fixation for type III open tibial fractures. , 1990, The Journal of bone and joint surgery. British volume.

[2]  J Kenwright,et al.  The influence of induced micromovement upon the healing of experimental tibial fractures. , 1985, The Journal of bone and joint surgery. British volume.

[3]  J. Steuer TREATMENT OF GRADE-IIIB OPEN TIBIAL FRACTURES , 1994 .

[4]  R. Gustilo,et al.  JSBS classics. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones. Retrospective and prospective analyses. , 1976, The Journal of bone and joint surgery. American volume.

[5]  A. Kyrö,et al.  Conservative treatment of tibial fractures. Results in a series of 163 patients. , 1991, Annales chirurgiae et gynaecologiae.

[6]  C. Lavy,et al.  Cyclical micromovement and fracture healing. , 1995, The Journal of bone and joint surgery. British volume.

[7]  G J Hooper,et al.  Conservative management or closed nailing for tibial shaft fractures. A randomised prospective trial. , 1991, The Journal of bone and joint surgery. British volume.

[8]  M. Järvinen,et al.  Anterior Knee Pain After Intramedullary Nailing of Fractures of the Tibial Shaft: A Prospective, Randomized Study Comparing Two Different Nail-Insertion Techniques , 2002, The Journal of bone and joint surgery. American volume.

[9]  M. Bhandari,et al.  Type-II Error Rates (Beta Errors) of Randomized Trials in Orthopaedic Trauma , 2001, The Journal of bone and joint surgery. American volume.

[10]  J. Styf,et al.  Percutaneous intramedullary nailing of tibial shaft fractures: a new approach for prevention of anterior knee pain. , 2001, Injury.

[11]  R. Johner,et al.  Classification of tibial shaft fractures and correlation with results after rigid internal fixation. , 1983, Clinical orthopaedics and related research.

[12]  J. Keating,et al.  Knee pain after tibial nailing. , 1997, Journal of orthopaedic trauma.

[13]  C. Court-Brown,et al.  Compartment pressures after intramedullary nailing of the tibia. , 1990, The Journal of bone and joint surgery. British volume.

[14]  C. Krettek,et al.  Superior Results of Tibial Rodding Versus External Fixation in Grade 3B Fractures , 1997, Clinical orthopaedics and related research.

[15]  A. Emami,et al.  Treatment of closed tibial shaft fractures with unilateral external fixation. , 1995, Injury.

[16]  C. Court-Brown,et al.  Closed intramedullary tibial nailing. Its use in closed and type I open fractures. , 1990, The Journal of bone and joint surgery. British volume.

[17]  C. Court-Brown,et al.  Knee pain after intramedullary tibial nailing: its incidence, etiology, and outcome. , 1997, Journal of orthopaedic trauma.

[18]  R. Hammer,et al.  Improved external skeletal fixation for unstable fractures. , 1987, Clinical orthopaedics and related research.

[19]  J. Watson Treatment of unstable fractures of the shaft of the tibia. , 1994, The Journal of bone and joint surgery. American volume.

[20]  J L Cunningham,et al.  Axial movement and tibial fractures. A controlled randomised trial of treatment. , 1991, The Journal of bone and joint surgery. British volume.

[21]  R. Buckley,et al.  Rotational Malalignment of the Tibia Following Reamed Intramedullary Nail Fixation , 2004, Journal of orthopaedic trauma.

[22]  J. Insall,et al.  Current Concepts Review: patellar pain. , 1982, The Journal of bone and joint surgery. American volume.

[23]  G. Bastiani,et al.  The treatment of fractures with a dynamic axial fixator. , 1984, The Journal of bone and joint surgery. British volume.

[24]  R. Gustilo,et al.  OTD classic article review - Gustillo RB, Anderson JT (1976) Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses , 2002, The Journal of bone and joint surgery. American volume.

[25]  A. Mølster,et al.  Open Tibial Fractures Treated With the Ex-fi-re External Fixation System , 1996, Clinical orthopaedics and related research.

[26]  A. Alho,et al.  Comparison of functional bracing and locked intramedullary nailing in the treatment of displaced tibial shaft fractures. , 1992, Clinical orthopaedics and related research.

[27]  Neil,et al.  TREATMENT OF GRADE-IIIB OPEN TIBIAL FRACTURES , 2005 .

[28]  C. Court-Brown,et al.  Locked intramedullary nailing of open tibial fractures. , 1991, The Journal of bone and joint surgery. British volume.

[29]  E Y Chao,et al.  Effects of axial dynamization on bone healing. , 1993, The Journal of trauma.

[30]  J. Taylor,et al.  Treatment of open fractures of the tibial shaft with the use of interlocking nailing without reaming. , 1992, The Journal of bone and joint surgery. American volume.

[31]  L. Bone,et al.  Treatment of tibial fractures by reaming and intramedullary nailing. , 1986, The Journal of bone and joint surgery. American volume.

[32]  A. Alho,et al.  Locked intramedullary nailing for displaced tibial shaft fractures. , 1990, The Journal of bone and joint surgery. British volume.

[33]  C. Court-Brown Reamed Intramedullary Tibial Nailing: An Overview and Analysis of 1106 Cases , 2004, Journal of orthopaedic trauma.