An intrinsically compliant robotic orthosis for treadmill training.

A new intrinsically compliant robotic orthosis powered by pneumatic muscle actuators (PMA) was developed for treadmill training of neurologically impaired subjects. The robotic orthosis has hip and knee sagittal plane rotations actuated by antagonistic configuration of PMA. The orthosis has passive mechanisms to allow vertical and lateral translations of the trunk and a passive hip abduction/adduction joint. A foot lifter having a passive spring mechanism was used to ensure sufficient foot clearance during swing phase. A trajectory tracking controller was implemented to evaluate the performance of the robotic orthosis on a healthy subject. The results show that the robotic orthosis is able to perform the treadmill training task by providing sufficient torques to achieve physiological gait patterns and a realistic stepping experience. The orthosis is a new addition to the rapidly advancing field of robotic orthoses for treadmill training.

[1]  S.K. Agrawal,et al.  Robot assisted gait training with active leg exoskeleton (ALEX) , 2009, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[2]  Jiping He,et al.  Design and Control of RUPERT: A Device for Robotic Upper Extremity Repetitive Therapy , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[3]  Domenico Campolo,et al.  Intrinsic Constraints of Neural Origin: Assessment and Application to Rehabilitation Robotics , 2009, IEEE Transactions on Robotics.

[4]  R. Riener,et al.  Patient-cooperative strategies for robot-aided treadmill training: first experimental results , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[5]  V. Dietz,et al.  Treadmill training of paraplegic patients using a robotic orthosis. , 2000, Journal of rehabilitation research and development.

[6]  Martin Buss,et al.  Compliant actuation of rehabilitation robots , 2008, IEEE Robotics & Automation Magazine.

[7]  S.J. Harkema,et al.  A Robot and Control Algorithm That Can Synchronously Assist in Naturalistic Motion During Body-Weight-Supported Gait Training Following Neurologic Injury , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  Liang Yang,et al.  Sliding mode tracking for pneumatic muscle actuators in opposing pair configuration , 2005, IEEE Transactions on Control Systems Technology.

[9]  R. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[10]  J. Burdick,et al.  Implications of Assist-As-Needed Robotic Step Training after a Complete Spinal Cord Injury on Intrinsic Strategies of Motor Learning , 2006, The Journal of Neuroscience.

[11]  David J. Reinkensmeyer,et al.  A robotic device for manipulating human stepping , 2006, IEEE Transactions on Robotics.

[12]  M. Morari,et al.  Adaptive robotic rehabilitation of locomotion: a clinical study in spinally injured individuals , 2003, Spinal Cord.

[13]  Jill M. Landry,et al.  A cable-driven locomotor training system for restoration of gait in human SCI. , 2011, Gait & posture.

[14]  R. Riener,et al.  A Novel Method for Automatic Treadmill Speed Adaptation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[15]  C. Phillips,et al.  Modeling the Dynamic Characteristics of Pneumatic Muscle , 2003, Annals of Biomedical Engineering.

[16]  Sheng Quan Xie,et al.  Robot assisted treadmill training: mechanisms and training strategies. , 2011, Medical engineering & physics.

[17]  Richard Quint van der Linde,et al.  Design, analysis, and control of a low power joint for walking robots, by phasic activation of McKibben muscles , 1999, IEEE Trans. Robotics Autom..

[18]  Blake Hannaford,et al.  Measurement and modeling of McKibben pneumatic artificial muscles , 1996, IEEE Trans. Robotics Autom..

[19]  F. Müller,et al.  Effects of Locomotion Training With Assistance of a Robot-Driven Gait Orthosis in Hemiparetic Patients After Stroke: A Randomized Controlled Pilot Study , 2007, Stroke.

[20]  Daniel P Ferris,et al.  An improved powered ankle-foot orthosis using proportional myoelectric control. , 2006, Gait & posture.

[21]  Frans C. T. van der Helm,et al.  A Series Elastic- and Bowden-Cable-Based Actuation System for Use as Torque Actuator in Exoskeleton-Type Robots , 2006, Int. J. Robotics Res..

[22]  Ayman Habib,et al.  OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement , 2007, IEEE Transactions on Biomedical Engineering.

[23]  J Ueda,et al.  Individual Muscle Control Using an Exoskeleton Robot for Muscle Function Testing , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[24]  H. van der Kooij,et al.  Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.