Energy Optimization for Transcritical CO2 Heat Pump for Combined Heating and Cooling and Thermal Storage Applications

A transcritical heat pump (THP) cycle using carbon dioxide (CO2) as the refrigerant is known to feature an excellent coefficient of performance (COP) as a thermodynamic system. Using this feature, we are designing and building a system that combines a water-to-water CO2 heat pump with both hot and cold thermal storages know as Thermal Battery (TB) (Blarke, 2012). Smart and effective use of intermittent renewable energy resources (for example solar and wind power) is obtained supplying water heating (>70 o C) and cooling services (<10 o C) for residential and commercial buildings. Our fundamental hypothesis is that if electricity generated by intermittent sources is destined for thermal end-uses an efficient conversion of electricity to thermal energy and storage enables a flexible power supply. Thermal storage is more cost-effective than any electro-chemical or mechanical storage technology. The usability and the cost effectiveness are critical for smart grid policies on large-scale integration of intermittent renewables. In this paper, we present an analytic thermodynamic model that predicts the effect of temperature and flow rate of hot and cold water circulation on system COP. The analytical predictions are consistent with the experimental results (Sarkar, 2010).

[1]  W. B. Veltkamp,et al.  The actual benefits of thermally stratified storage in a small and a medium size solar system , 1979 .

[2]  K. Sumathy,et al.  Transcritical carbon dioxide heat pump systems: A review , 2011 .

[3]  K.G.T. Hollands,et al.  A review of low-flow, stratified-tank solar water heating systems , 1989 .

[4]  R. Belmans,et al.  Voltage fluctuations on distribution level introduced by photovoltaic systems , 2006, IEEE Transactions on Energy Conversion.

[5]  Willy Adriansyah,et al.  Combined Air Conditioning and Tap Water Heating Plant, Using CO2 as Refrigerant for Indonesian Climate Condition , 2004 .

[6]  Simon Furbo,et al.  Multilayer fabric stratification pipes for solar tanks , 2007 .

[7]  Morten Boje Blarke,et al.  Smart intermittency-friendly cogeneration: Techno-economic performance of innovative double storage concept for integrating compression heat pumps in distributed cogeneration , 2011 .

[8]  Jahar Sarkar,et al.  Performance of a Transcritical CO2 Heat Pump for Simultaneous Water Cooling and Heating , 2009 .

[9]  Ramón Cabello,et al.  Experimental evaluation of the energy efficiency of a CO2 refrigerating plant working in transcritical conditions , 2008 .

[10]  Robert McDowall,et al.  Fundamentals of HVAC systems , 2007 .

[11]  S. Garimella,et al.  Water-coupled carbon dioxide microchannel gas cooler for heat pump water heaters: Part I - Experiments , 2011 .

[12]  Jostein Pettersen,et al.  Fundamental process and system design issues in CO2 vapor compression systems , 2004 .

[13]  Ryohei Yokoyama,et al.  Performance Analysis of a Hot Water Supply System with a CO2 Heat Pump by Numerical Simulation , 2006 .

[14]  Morten Boje Blarke,et al.  Thermal battery with CO2 compression heat pump: Techno-economic optimization of a high-efficiency Smart Grid option for buildings , 2012 .

[15]  W. L. Lee,et al.  Combined space cooling and water heating system for Hong Kong residences , 2010 .

[16]  Friedrich Kauf,et al.  Determination of the optimum high pressure for transcritical CO2-refrigeration cycles , 1999 .

[17]  Petter Nekså,et al.  CO2 heat pump systems , 2002 .

[18]  Shengming Liao,et al.  A correlation of optimal heat rejection pressures in transcritical carbon dioxide cycles , 2000 .

[19]  Jahar Sarkar,et al.  Optimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications , 2004 .

[20]  W. Wagner,et al.  A New Equation of State for Carbon Dioxide Covering the Fluid Region from the Triple‐Point Temperature to 1100 K at Pressures up to 800 MPa , 1996 .

[21]  Srinivas Garimella,et al.  Water-coupled carbon dioxide microchannel gas cooler for heat pump water heaters: Part II – Model development and validation , 2011 .

[22]  Junjie Gu,et al.  The optimum high pressure for CO2 transcritical refrigeration systems with internal heat exchangers , 2005 .

[23]  M. Ghiaasiaan Convective Heat and Mass Transfer: Index , 2011 .