An equivalent square field formula for determining head scatter factors of rectangular fields.

A simple formula is derived for the calculation of an equivalent square field that gives the same head scatter factor as a given rectangular field. This formula is based strictly on the configuration of a medical linear accelerator treatment head. The geometric parameters used are the distances between the target and the top of each field-defining aperture. The formula accounts for both the effect of field elongation and the collimator exchange effect. This method predicts the output to within 1% accuracy for both open and wedged fields and does not require any new measured data other than the field size dependence of head scatter for a range of square field sizes. Interestingly, the formula we derived has the same format as the formula that was empirically obtained by Vadash and Bjärngard [Med. Phys. 20, 733-734 (1993)].

[1]  F. Roberts The Treatment of Carcinoma of the Lung , 1944 .

[2]  A Fenster,et al.  X-ray sources of medical linear accelerators: focal and extra-focal radiation. , 1993, Medical physics.

[3]  B. Bjärngard,et al.  An equivalent-square formula for head-scatter factors. , 1993, Medical physics.

[4]  J. Venselaar,et al.  The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  R F Moyer,et al.  Systematic patient-dose errors for 4- and 10-MeV microwave linear accelerators associated with rectangular collimator settings. , 1978, Radiology.

[6]  K. Kase,et al.  Head scatter data for several linear accelerators (4-18 MV). , 1986, Medical physics.

[7]  R. Sloboda,et al.  Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalism. , 1995, Medical physics.

[8]  T D STERLING,et al.  AUTOMATION OF RADIATION TREATMENT PLANNING. IV. DERIVATION OF A MATHEMATICAL EXPRESSION FOR THE PER CENT DEPTH DOSE SURFACE OF COBALT 60 BEAMS AND VISUALISATION OF MULTIPLE FIELD DOSE DISTRIBUTIONS. , 1964, The British journal of radiology.

[9]  M. Tatcher,et al.  Head-scatter factors in rectangular photon fields. , 1993, Medical physics.

[10]  K L Lam,et al.  Flattening-filter-based empirical methods to parametrize the head scatter factor. , 1996, Medical physics.

[11]  A Ahnesjö,et al.  Analytic modeling of photon scatter from flattening filters in photon therapy beams. , 1994, Medical physics.