Potentials of pervaporation to assist VOCs’ recovery by liquid absorption

Abstract Gas treatment by liquid absorption is a well-known process to remove volatile organic compounds (VOCs) from industrial waste gases. Usually the liquid is an organic solvent of high boiling point; however, after VOCs’ absorption it must be regenerated for the possible reuse and this step is classically achieved by heating the liquid. The paper presents the work directed to investigate an alternative regeneration step based on a liquid–vapour membrane separation, i.e. pervaporation. Because most of the energy required in pervaporation processes is consumed to remove the minor component from the initial mixture by selective permeation through the membrane, one can expect a significant energy cut in the operational costs linked to the regeneration of the liquid if the pervaporation step can substitute the heating one. The results reported here show that the technological possibility to use pervaporation is first governed by the stability of the membrane in the absorption liquid. The viability of the overall process is actually controlled by the mutual affinity between the VOCs, the solvent phase and the polymeric material. As a matter of fact, whereas VOCs have to exhibit strong affinities to both the solvent and the membrane material, the polymer has to be well resistant and even repellent to the solvent to avoid the possible sorption in the membrane that would drastically depress the pervaporation efficiency. In other words the membrane transport properties must be specific for the VOCs. This goal was reached following several experimental approaches, going from membrane modifications to the selection of suitable heavy protic solvents. Hence it has been shown for the case of dichloromethane (DCM) that low molecular weights polyalcohols (e.g. glycols) appeared to be suitable media to allow in particular the specific transport of DCM. On the other hand, polydimethylsiloxane (PDMS) based membranes were selected for their stability in these polyglycols and for their marked affinity for DCM. The simulation of the hybrid gas treatment process at pilot-scale was also achieved by a simple model relying on experimental data for both vapour liquid equilibria and permeation flux. A simple comparison of the energy needed to regenerate the heavy solvent by each possible step has also been made.

[1]  L. Vane,et al.  Recent advances in VOCs removal from water by pervaporation. , 2003, Journal of hazardous materials.

[2]  É. Favre,et al.  Isothermal and nonisothermal permeation of an organic vapor through a dense polymer membrane , 1999 .

[3]  F. Lapicque,et al.  Characterization of the SO2−N-Formylmorpholine Complex: Application to a Regenerative Process for Waste Gas Scrubbing , 2002 .

[4]  D. Roizard,et al.  Selective Sulfur Dioxide Removal Using Organic Solvents , 1997 .

[5]  Scott Lynn,et al.  Solubility of hydrogen sulfide, sulfur dioxide, carbon dioxide, propane, and n-butane in poly(glycol ethers) , 1988 .

[6]  D. Roizard,et al.  New copolyimide membranes with high siloxane content designed to remove polar organics from water by pervaporation , 2004 .

[7]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[8]  K. Sirkar,et al.  Membrane‐based absorption of VOCs from a gas stream , 1996 .

[9]  R. Baker,et al.  Recovery of VOCs from high-volume, low-VOC-concentration air streams , 2001 .

[10]  Keith Scott,et al.  Handbook of Industrial Membranes , 1995 .

[11]  P. Moulin,et al.  Treatment of gas containing hydrophobic VOCs by a hybrid absorption-pervaporation process : The case of toluene , 2007 .

[12]  W. L. Robb,et al.  THIN SILICONE MEMBRANES‐THEIR PERMEATION PROPERTIES AND SOME APPLICATIONS , 1968, Annals of the New York Academy of Sciences.

[13]  K. Sirkar,et al.  Regenerative oil scrubbing of volatile organic compounds from a gas stream in hollow fiber membrane devices , 1999 .

[14]  D. E. Clough,et al.  Pervaporation–air stripping hybrid process for removal of VOCs from groundwater , 2004 .

[15]  R. Baker Membrane Technology and Applications , 1999 .

[16]  Sudipta Bhattacharya,et al.  Concentration polarization, separation factor, and Peclet number in membrane processes , 1997 .

[17]  C. A. Smolders,et al.  Preparation of zeolite filled glassy polymer membranes , 1994 .

[18]  Sauro Pierucci,et al.  Modelling, design and commissioning of a sustainable process for VOCs recovery from spray paint booths , 2003 .

[19]  Y. Shah The effect of solid wettability on gas—liquid mass transfer in a slurry bubble column , 1990 .

[20]  Arvo Lannus,et al.  Gas‐Liquid Reactions , 1970 .

[21]  F. Lapicque,et al.  Absorption of Chlorinated VOCs in High-Boiling Solvents: Determination of Henry's Law Constants and Infinite Dilution Activity Coefficients , 2004 .

[22]  K. Sirkar,et al.  A pilot-scale demonstration of a membrane-based absorption-stripping process for removal and recovery of volatile organic compounds , 2001 .

[23]  Faisal Khan,et al.  Removal of Volatile Organic Compounds from polluted air , 2000 .

[24]  S. Sikdar,et al.  Pervaporation Using Adsorbent-Filled Membranes , 1996 .

[25]  Arnold Weissberger,et al.  Organic solvents;: Physical properties and methods of purification , 1970 .

[26]  S. Sikdar,et al.  Sorption, diffusion and permeation of 1,1,1-trichloroethane through adsorbent-filled polymeric membranes☆ , 1995 .

[27]  Heinz-Wolfgang Hring,et al.  Industrial Gases Processing , 2007 .