Effect of innervation zones in estimating biceps brachii force-EMG relationship during isometric contraction.

Measuring muscle forces in vivo is invasive and consequently indirect methods e.g., electromyography (EMG) are used in estimating muscular force production. The aim of the present paper was to examine what kind of effect the disruption of the physiological signal caused by the innervation zone has in predicting the force/torque output from surface EMG. Twelve men (age 26 (SD ±3)years; height 179 (±6)cm; body mass 73 (±6)kg) volunteered as subjects. They were asked to perform maximal voluntary isometric contraction (MVC) in elbow flexion, and submaximal contractions at 10%, 20%, 30%, 40%, 50% and 75% of the recorded MVC. EMG was measured from biceps brachii muscle with an electrode grid of 5 columns×13 rows. Force-EMG relationships were determined from individual channels and as the global mean value. The relationship was deemed inconsistent if EMG value did not increase in successive force levels. Root mean squared errors were calculated for 3rd order polynomial fits. All subjects had at least one (4-52) inconsistent channel. Two subjects had inconsistent relationship calculated from the global mean. The mean root mean squared error calculated using leave one out method for the fits of the individual channels (0.33±0.17) was higher (P<0.001) than the error for the global mean fit (0.16±0.08). It seems that the disruption of the physiological signal caused by the innervation zone affects the consistency of the force-EMG relationship on single bipolar channel level. Multichannel EMG recordings used for predicting force overcame this disruption.

[1]  P. Komi,et al.  Biomechanical loading of Achilles tendon during normal locomotion. , 1992, Clinics in sports medicine.

[2]  D. Farina,et al.  Effect of joint angle on EMG variables in leg and thigh muscles , 2001, IEEE Engineering in Medicine and Biology Magazine.

[3]  Dinesh Kumar,et al.  An accurate bicep muscle model with sEMG and muscle force outputs , 2010 .

[4]  G Sjøgaard,et al.  Selective activation of neuromuscular compartments within the human trapezius muscle. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[5]  P. Komi,et al.  Achilles tendon loading during walking: application of a novel optic fiber technique , 1998, European Journal of Applied Physiology and Occupational Physiology.

[6]  D. Kosarov,et al.  Some features of different motor units in human biceps brachii , 1974, Pflügers Archiv.

[7]  K Roeleveld,et al.  EMG amplitude distribution changes over the upper trapezius muscle are similar in sustained and ramp contractions , 2006, Acta physiologica.

[8]  K. Roeleveld,et al.  Inhomogeneities in muscle activation reveal motor unit recruitment. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[9]  B. Freriks,et al.  Development of recommendations for SEMG sensors and sensor placement procedures. , 2000, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[10]  J Duchêne,et al.  Variability of some SEMG parameter estimates with electrode location. , 1998, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[11]  A. Goodship,et al.  Bone deformation recorded in vivo from strain gauges attached to the human tibial shaft. , 1975, Acta orthopaedica Scandinavica.

[12]  D B Burr,et al.  A method suitable for in vivo measurement of bone strain in humans. , 1997, Journal of biomechanics.

[13]  Thomas Schmitz-Rode,et al.  Surface electromyography and muscle force: limits in sEMG-force relationship and new approaches for applications. , 2009, Clinical biomechanics.

[14]  I. Kingma,et al.  Heterogeneity of muscle activation in relation to force direction: a multi-channel surface electromyography study on the triceps surae muscle. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[15]  David B. Burr,et al.  In vivo strain measurements to evaluate the strengthening potential of exercises on the tibial bone , 2000 .

[16]  Luciano Luporini Menegaldo,et al.  Individual-specific muscle maximum force estimation using ultrasound for ankle joint torque prediction using an EMG-driven Hill-type model. , 2010, Journal of biomechanics.

[17]  G. Melchiorri,et al.  A method for positioning electrodes during surface EMG recordings in lower limb muscles , 2004, Journal of Neuroscience Methods.

[18]  R.J. Triolo,et al.  The theoretical development of a multichannel time-series myoprocessor for simultaneous limb function detection and muscle force estimation , 1989, IEEE Transactions on Biomedical Engineering.

[19]  D. Lloyd,et al.  An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo. , 2003, Journal of biomechanics.

[20]  Jaap H van Dieën,et al.  Methodological aspects of SEMG recordings for force estimation--a tutorial and review. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[21]  K Søgaard,et al.  The use of EMG biofeedback for learning of selective activation of intra-muscular parts within the serratus anterior muscle: a novel approach for rehabilitation of scapular muscle imbalance. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[22]  D. Winter,et al.  Models of recruitment and rate coding organization in motor-unit pools. , 1993, Journal of neurophysiology.

[23]  Thomas J Roberts,et al.  Task-dependent force sharing between muscle synergists during locomotion in turkeys , 2008, Journal of Experimental Biology.

[24]  D. MacIsaac,et al.  Innervation zone shift with changes in joint angle in the brachial biceps. , 2006, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[25]  Tadashi Masuda,et al.  The Position of Innervation Zones in the Biceps Brachii Investigated by Surface Electromyography , 1985, IEEE Transactions on Biomedical Engineering.

[26]  V. Edgerton,et al.  Nonuniform strain of human soleus aponeurosis-tendon complex during submaximal voluntary contractions in vivo. , 2003, Journal of applied physiology.

[27]  R. Nazer,et al.  Analysis of dynamic strains in tibia during human locomotion based on flexible multibody approach integrated with magnetic resonance imaging technique , 2008 .

[28]  S L Delp,et al.  A graphics-based software system to develop and analyze models of musculoskeletal structures. , 1995, Computers in biology and medicine.

[29]  S. Metral,et al.  Relationship between force and integrated EMG activity during voluntary isometric anisotonic contraction , 2004, European Journal of Applied Physiology and Occupational Physiology.

[30]  C. Weaver,et al.  Biomechanical Analysis of an Exercise Program for Forces and Stresses in the Hip Joint and Femoral Neck , 1996 .

[31]  M. Stone Cross‐Validatory Choice and Assessment of Statistical Predictions , 1976 .

[32]  Andreas Daffertshofer,et al.  Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis , 2006, IEEE Transactions on Biomedical Engineering.

[33]  Paavo V. Komi,et al.  In vivo human triceps surae and quadriceps femoris muscle function in a squat jump and counter movement jump , 2000, European Journal of Applied Physiology.

[34]  E. Adrian,et al.  The discharge of impulses in motor nerve fibres , 1929, The Journal of physiology.

[35]  I. Kingma,et al.  Towards optimal multi-channel EMG electrode configurations in muscle force estimation: a high density EMG study. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[36]  N. Ostlund,et al.  Location of innervation zone determined with multichannel surface electromyography using an optical flow technique. , 2007, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[37]  P. Komi,et al.  Innervation zone shift at different levels of isometric contraction in the biceps brachii muscle. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.