A dozen ways to prevent nickel-titanium rotary instrument fracture

ABSTRACT Background and Overview With the increased use of nickel-titanium (NiTi) rotary instruments for root canal preparation in endodontics, instrument fracture has become more prevalent. Extensive research has been conducted on the physical properties and mechanical characteristics of NiTi rotary instruments, as well as the factors that can contribute to instrument failure. NiTi rotary instruments are subjected to torque and are susceptible to cyclic fatigue, which are the main causes of instrument fracture. However, with an understanding of how these instruments function in preparing root canals and by applying ways to reduce torque-generated metal fatigue, clinicians can use the instruments safely in clinical practice. Results The author presents 12 measures that clinicians can take to prevent NiTi rotary instrument fracture and discusses them in detail. Clinical Implications NiTi rotary instrument fracture complicates the progress, and compromises the prognosis of endodontic treatment. However, when clinicians take appropriate measures, rotary instrument fractures can be prevented.

[1]  J. Leeb Canal orifice enlargement as related to biomechanical preparation. , 1983, Journal of endodontics.

[2]  H. Rappaport,et al.  EDTA and urea peroxide for root canal preparation. , 1969, Journal of the American Dental Association.

[3]  Fracture of ProFile nickel-titanium rotary instruments: a laboratory simulation assessment. , 2006, International endodontic journal.

[4]  H H Messer,et al.  Torque during canal instrumentation using rotary nickel-titanium files. , 2000, Journal of endodontics.

[5]  John M Powers,et al.  SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical Use. , 2005, Journal of endodontics.

[6]  G. Yared,et al.  Failure of ProFile instruments used with air, high torque control, and low torque control motors. , 2002, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[7]  G. Yared,et al.  Influence of torque control motors and the operator's proficiency on ProTaper failures. , 2003, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[8]  M Hülsmann,et al.  Removal of fractured instruments using a combined automated/ultrasonic technique. , 1994, Journal of endodontics.

[9]  Peter Parashos,et al.  Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: an experimental study. , 2003, Journal of endodontics.

[10]  G. Cantatore,et al.  The influence of a manual glide path on the separation rate of NiTi rotary instruments. , 2005, Journal of endodontics.

[11]  Bor-Shiunn Lee,et al.  Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. , 2002, Journal of endodontics.

[12]  Janik Jm Access cavity preparation. , 1984 .

[13]  M Hülsmann,et al.  Influence of several factors on the success or failure of removal of fractured instruments from the root canal. , 1999, Endodontics & dental traumatology.

[14]  Maria Guiomar de Azevedo Bahia,et al.  Fatigue Resistance of Engine-Driven Rotary Nickel- Titanium Endodontic Instruments , 2002 .

[15]  David D Roland,et al.  The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments. , 2002, Journal of endodontics.

[16]  Jean-Paul Micallef,et al.  Location of contact areas on rotary Profile1 instruments in relationship to the forces developed during mechanical preparation on extracted teeth , 1999 .

[17]  G. Yared,et al.  Influence of rotational speed, torque and operator's proficiency on ProFile failures. , 2001, International endodontic journal.

[18]  T. Sotokawa A systematic approach to preventing intracanal breakage of endodontic files. , 1990, Endodontics & dental traumatology.

[19]  Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. , 2001, Journal of endodontics.

[20]  Comparison of nickel-titanium file distortion using electric and air-driven handpieces. , 2001, Journal of endodontics.

[21]  Geoff Bateman,et al.  Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. , 1999 .

[22]  Yufeng Zheng,et al.  Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections. , 2006, Journal of endodontics.

[23]  H Schilder,et al.  Filling root canals in three dimensions. , 1967, Dental clinics of North America.

[24]  E. Berutti,et al.  Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments. , 2004, Journal of endodontics.

[25]  L. Morgan,et al.  An evaluation of the crown-down pressureless technique. , 1984, Journal of endodontics.

[26]  V. Buono,et al.  Surface analysis of ProFile instruments by scanning electron microscopy and X-ray energy-dispersive spectroscopy: a preliminary study. , 2002, International endodontic journal.

[27]  G. Yared,et al.  Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files. , 2002, International endodontic journal.

[28]  J. Baumgartner,et al.  A scanning electron microscopic evaluation of four root canal irrigation regimens. , 1987, Journal of endodontics.

[29]  O. Peters,et al.  Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments. , 2005, Journal of endodontics.

[30]  H. Messer,et al.  The impact of instrument fracture on outcome of endodontic treatment. , 2005 .

[31]  B. Martín,et al.  The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments. , 2002, Journal of endodontics.

[32]  G M Yared,et al.  Failure of ProFile Ni-Ti instruments used by an inexperienced operator under access limitations. , 2002, International endodontic journal.

[33]  B. Martín,et al.  Factors influencing the fracture of nickel-titanium rotary instruments. , 2003, International endodontic journal.

[34]  G Gambarini,et al.  Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. , 2001, International endodontic journal.

[35]  G. Kuhn,et al.  Influence of structure on nickel-titanium endodontic instruments failure. , 2001, Journal of endodontics.

[36]  J. P. Pruett,et al.  Cyclic fatigue testing of nickel-titanium endodontic instruments. , 1997, Journal of endodontics.

[37]  Ove A Peters,et al.  Analysis of torque and force with differently tapered rotary endodontic instruments in vitro. , 2005, Journal of Endodontics.

[38]  M Morin,et al.  CEREC: the power of technology. , 2001, Compendium of continuing education in dentistry.

[39]  E. Komaroff,et al.  Nickel-titanium rotary instrument fracture: a clinical practice assessment. , 2006, International endodontic journal.

[40]  John C. Mitchell,et al.  Scanning electron microscope observations of new and used nickel-titanium rotary files. , 2003, Journal of endodontics.

[41]  Harold H. Messer,et al.  Complications Associated with Fractured File Removal Using an Ultrasonic Technique , 2005 .

[42]  Peter Parashos,et al.  Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use. , 2004, Journal of endodontics.

[43]  J. Powers,et al.  The deterioration of rotary nickel-titanium files under controlled conditions. , 2002, Journal of endodontics.

[44]  Scott A Schwartz,et al.  Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model. , 2006, Journal of endodontics.

[45]  B. Sattapan,et al.  Defects in rotary nickel-titanium files after clinical use. , 2000, Journal of endodontics.

[46]  G. Cheung,et al.  Comparison of defects in ProFile and ProTaper systems after clinical use. , 2006, Journal of endodontics.

[47]  H Schilder,et al.  Cleaning and shaping the root canal. , 1974, Dental clinics of North America.

[48]  E. Natkin,et al.  Relationship of broken root canal instruments to endodontic case prognosis: a clinical investigation. , 1970, Journal of the American Dental Association.

[49]  F E Pink,et al.  Effect of rotational speed on nickel-titanium file distortion. , 1999, Journal of endodontics.

[50]  D. Dederich,et al.  The effects of cyclical axial motion on rotary endodontic instrument fatigue. , 1986, Oral surgery, oral medicine, and oral pathology.

[51]  D. McComb,et al.  A preliminary scanning electron microscopic study of root canals after endodontic procedures. , 1975, Journal of endodontics.

[52]  G. Condorelli,et al.  Defects in GT rotary instruments after use: an SEM study. , 2001, Journal of endodontics.

[53]  In vitro study of the torsional properties of new and used ProFile nickel titanium rotary files. , 2004, Journal of endodontics.

[54]  P Machtou,et al.  Failure of ProFile instruments used with high and low torque motors. , 2001, International endodontic journal.

[55]  P. Eleazer,et al.  A comparison of torque required to fracture rotary files with tips bound in simulated curved canal. , 2005, Journal of endodontics.

[56]  S. Seltzer,et al.  Scanning electron microscopic study of the efficacy of various irrigating solutions. , 1975, Journal of endodontics.