Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy

Prompt gamma rays emitted from biological tissues during proton irradiation carry dosimetric and spectroscopic information that can assist with treatment verification and provide an indication of the biological response of the irradiated tissues. Compton cameras are capable of determining the origin and energy of gamma rays. However, prompt gamma monitoring during proton therapy requires new Compton camera designs that perform well at the high gamma energies produced when tissues are bombarded with therapeutic protons. In this study we optimize the materials and geometry of a three-stage Compton camera for prompt gamma detection and calculate the theoretical efficiency of such a detector. The materials evaluated in this study include germanium, bismuth germanate (BGO), NaI, xenon, silicon and lanthanum bromide (LaBr(3)). For each material, the dimensions of each detector stage were optimized to produce the maximum number of relevant interactions. These results were used to predict the efficiency of various multi-material cameras. The theoretical detection efficiencies of the most promising multi-material cameras were then calculated for the photons emitted from a tissue-equivalent phantom irradiated by therapeutic proton beams ranging from 50 to 250 MeV. The optimized detector stages had a lateral extent of 10 × 10 cm(2) with the thickness of the initial two stages dependent on the detector material. The thickness of the third stage was fixed at 10 cm regardless of material. The most efficient single-material cameras were composed of germanium (3 cm) and BGO (2.5 cm). These cameras exhibited efficiencies of 1.15 × 10(-4) and 9.58 × 10(-5) per incident proton, respectively. The most efficient multi-material camera design consisted of two initial stages of germanium (3 cm) and a final stage of BGO, resulting in a theoretical efficiency of 1.26 × 10(-4) per incident proton.

[1]  Anatoly Rosenfeld,et al.  Assessment of out-of-field absorbed dose and equivalent dose in proton fields. , 2009, Medical physics.

[2]  E. Pedroni,et al.  Secondary neutron dose during proton therapy using spot scanning. , 2002, International journal of radiation oncology, biology, physics.

[3]  J. Archambeau,et al.  Visualization and Transport of Positron Emission from Proton Activation in vivo , 1978, Science.

[4]  G. W. Phillips Gamma-ray imaging with Compton cameras , 1995 .

[5]  M.-H. Richard,et al.  Design study of a Compton camera for prompt γ imaging during ion beam therapy , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[6]  G Ciangaru,et al.  Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study , 2009, Physics in medicine and biology.

[7]  Radhe Mohan,et al.  The M. D. Anderson proton therapy system. , 2009, Medical physics.

[8]  R. Cloutier Tissue Substitutes in Radiation Dosimetry and Measurement. , 1989 .

[9]  F. Rademakers,et al.  ROOT — An object oriented data analysis framework , 1997 .

[10]  F. SutcliffeJ,et al.  14.4MeVパルス中性子を用いた炭素,水素,酸素の同時測定の可能性 , 1991 .

[11]  A. Koehler,et al.  Measurement of neutron dose equivalent to proton therapy patients outside of the proton radiation field , 2002 .

[12]  Robert J. Ott,et al.  Gamma ray imaging with silicon detectors — A Compton camera for radionuclide imaging in medicine , 1988 .

[13]  Mike A. Smith,et al.  A feasibility study for the simultaneous measurement of carbon, hydrogen and oxygen using pulsed 14.4 MeV neutrons , 1991 .

[14]  Chan Hyeong Kim,et al.  Preliminary Study for Determination of Distal Dose Edge by Measuring 90-deg Prompt Gammas with an Array-Type Prompt Gamma Detection System , 2009 .

[15]  Steven J Frank,et al.  Variations in proton scanned beam dose delivery due to uncertainties in magnetic beam steering. , 2009, Medical physics.

[16]  Denis Dauvergne,et al.  Dose profile monitoring with carbon ions by means of prompt-gamma measurements , 2009 .

[17]  A. Zoglauer,et al.  A Tracking Compton-Scattering Imaging System for Hadron Therapy Monitoring , 2010, IEEE Transactions on Nuclear Science.

[18]  D Robertson,et al.  Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy , 2010, Physics in medicine and biology.

[19]  S Beddar,et al.  Measurement and calculation of characteristic prompt gamma ray spectra emitted during proton irradiation , 2009, Physics in medicine and biology.