Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy
暂无分享,去创建一个
Sam Beddar | Daniel Robertson | Jerimy C Polf | Steve W Peterson | M. Gillin | S. Beddar | S. Peterson | J. Polf | D. Robertson | Michael T Gillin
[1] Anatoly Rosenfeld,et al. Assessment of out-of-field absorbed dose and equivalent dose in proton fields. , 2009, Medical physics.
[2] E. Pedroni,et al. Secondary neutron dose during proton therapy using spot scanning. , 2002, International journal of radiation oncology, biology, physics.
[3] J. Archambeau,et al. Visualization and Transport of Positron Emission from Proton Activation in vivo , 1978, Science.
[4] G. W. Phillips. Gamma-ray imaging with Compton cameras , 1995 .
[5] M.-H. Richard,et al. Design study of a Compton camera for prompt γ imaging during ion beam therapy , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).
[6] G Ciangaru,et al. Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study , 2009, Physics in medicine and biology.
[7] Radhe Mohan,et al. The M. D. Anderson proton therapy system. , 2009, Medical physics.
[8] R. Cloutier. Tissue Substitutes in Radiation Dosimetry and Measurement. , 1989 .
[9] F. Rademakers,et al. ROOT — An object oriented data analysis framework , 1997 .
[10] F. SutcliffeJ,et al. 14.4MeVパルス中性子を用いた炭素,水素,酸素の同時測定の可能性 , 1991 .
[11] A. Koehler,et al. Measurement of neutron dose equivalent to proton therapy patients outside of the proton radiation field , 2002 .
[12] Robert J. Ott,et al. Gamma ray imaging with silicon detectors — A Compton camera for radionuclide imaging in medicine , 1988 .
[13] Mike A. Smith,et al. A feasibility study for the simultaneous measurement of carbon, hydrogen and oxygen using pulsed 14.4 MeV neutrons , 1991 .
[14] Chan Hyeong Kim,et al. Preliminary Study for Determination of Distal Dose Edge by Measuring 90-deg Prompt Gammas with an Array-Type Prompt Gamma Detection System , 2009 .
[15] Steven J Frank,et al. Variations in proton scanned beam dose delivery due to uncertainties in magnetic beam steering. , 2009, Medical physics.
[16] Denis Dauvergne,et al. Dose profile monitoring with carbon ions by means of prompt-gamma measurements , 2009 .
[17] A. Zoglauer,et al. A Tracking Compton-Scattering Imaging System for Hadron Therapy Monitoring , 2010, IEEE Transactions on Nuclear Science.
[18] D Robertson,et al. Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy , 2010, Physics in medicine and biology.