1030-nm nanosecond LIDT of dielectric coatings on yttrium aluminium garnet
暂无分享,去创建一个
Laser-induced damage threshold (LIDT) of dielectric coatings prepared on monocrystalline neodymium-doped yttrium aluminium garnet (YAG) substrates was studied. Various coating designs were prepared using either reactive or ionassisted e-beam deposition technology and tested at 1030 nm 10 ns in r-on-1 mode according to the ISO 21254 standard. Measured damage thresholds were compared and LIDT was discussed with respect to thin-film design and coating technology.
[1] Tomas Mocek,et al. Advanced LIDT testing station in the frame of the HiLASE Project , 2012, Laser Damage.
[2] Václav Škoda,et al. A comparison of LIDT behavior of AR-coated yttrium-aluminium-garnet substrates with respect to thin-film design and coating technology , 2018, Laser Damage.