Analysis of normal-appearing white matter of multiple sclerosis by tensor-based two-compartment model of water diffusion

AbstractObjectivesTo compare the significance of the two-compartment model, considering diffusional anisotropy with conventional diffusion analyzing methods regarding the detection of occult changes in normal-appearing white matter (NAWM) of multiple sclerosis (MS).MethodsDiffusion-weighted images (nine b-values with six directions) were acquired from 12 healthy female volunteers (22–52 years old, median 33 years) and 13 female MS patients (24–48 years old, median 37 years). Diffusion parameters based on the two-compartment model of water diffusion considering diffusional anisotropy was calculated by a proposed method. Other parameters including diffusion tensor imaging and conventional apparent diffusion coefficient (ADC) were also obtained. They were compared statistically between the control and MS groups.ResultsDiffusion of the slow diffusion compartment in the radial direction of neuron fibers was elevated in MS patients (0.121 × 10−3 mm2/s) in comparison to control (0.100 × 10−3 mm2/s), the difference being significant (P = 0.001). The difference between the groups was not significant in other comparisons, including conventional ADC and fractional anisotropy (FA) of diffusion tensor imaging.ConclusionThe proposed method was applicable to clinically acceptable small data. The parameters obtained by this method improved the detectability of occult changes in NAWM compared to the conventional methods.Key Points• Water diffusion was compared between the controls and multiple sclerosis patients. • A two-compartment model, considering diffusional anisotropy was selected for water diffusion analysis. • Axial and radial diffusion of fast and slow diffusion components were evaluated. • A new method was developed to obtain the metrics stably. • The metrics indicated high detectability of slight differences between the groups.

[1]  D. Le Bihan The ‘wet mind’: water and functional neuroimaging , 2007, Physics in medicine and biology.

[2]  Nadim Joni Shah,et al.  Non-Gaussian diffusion in human brain tissue at high b-factors as examined by a combined diffusion kurtosis and biexponential diffusion tensor analysis , 2011, NeuroImage.

[3]  M. Oudkerk,et al.  Relationships between brain water content and diffusion tensor imaging parameters (apparent diffusion coefficient and fractional anisotropy) in multiple sclerosis , 2006, European Radiology.

[4]  Hans Lassmann,et al.  Cortical demyelination and diffuse white matter injury in multiple sclerosis. , 2005, Brain : a journal of neurology.

[5]  P. Brugières,et al.  Water diffusion compartmentation at high b values in ischemic human brain. , 2004, AJNR. American journal of neuroradiology.

[6]  M Cercignani,et al.  Weekly diffusion-weighted imaging of normal-appearing white matter in MS , 2000, Neurology.

[7]  Masaaki Hori,et al.  Diffusional kurtosis imaging of normal-appearing white matter in multiple sclerosis: preliminary clinical experience , 2012, Japanese Journal of Radiology.

[8]  D. Le Bihan,et al.  Water diffusion compartmentation and anisotropy at high b values in the human brain , 2000, Magnetic resonance in medicine.

[9]  M. Filippi,et al.  Diffusion-weighted imaging in multiple sclerosis , 1999, The Italian Journal of Neurological Sciences.

[10]  C. Westin,et al.  Magnetic Resonance in Medicine 51:321–330 (2004) Biexponential Diffusion Tensor Analysis of Human Brain Diffusion Data , 2022 .

[11]  Abnormal diffusivity of normal appearing brain tissue in multiple sclerosis: a diffusion-weighted MR imaging study. , 2007, Journal of the Medical Association of Thailand = Chotmaihet thangphaet.

[12]  Elizabeth Fisher,et al.  Multiple sclerosis normal‐appearing white matter: Pathology–imaging correlations , 2011, Annals of neurology.

[13]  T. Obata,et al.  Analysis of Multiple B-Value Diffusion-Weighted Imaging in Pediatric Acute Encephalopathy , 2013, PloS one.

[14]  S. Maier,et al.  Normal brain and brain tumor: multicomponent apparent diffusion coefficient line scan imaging. , 2001, Radiology.

[15]  Jeffrey A. Cohen,et al.  Diagnostic criteria for multiple sclerosis: 2010 Revisions to the McDonald criteria , 2011, Annals of neurology.