Stabilization of a distributed DC power system by shaping loads input impedance: Feedforward stabilization

Power electronic converters and electric motor drives have become common loads in advanced power systems. Passive LC filters are often used in these systems to reduce the DC-link ripples. These filters are poorly damped for reducing the power losses as well as the size, weight and cost of the system. This may lead to instability phenomena if the load is tightly controlled and absorbs a power exceeding a limit depending on the filter parameters. The purpose of this paper is to present an input impedance shaping method to stabilize DC-link. A matrix filter is put in cascade with load's current controllers. The filter is designed to shape properly input impedance of the load while keeping its performances. Small signal stability of the DC power system is proved using this method. Simulation and experimental results confirm the effectiveness of the proposed stabilizer.

[1]  Mansour Tabari,et al.  Stability of a dc Distribution System for Power System Integration of Plug-In Hybrid Electric Vehicles , 2014, IEEE Transactions on Smart Grid.

[2]  Ali Emadi,et al.  Dynamic analysis of the interaction between an Interleaved Boost Converter with Coupled Inductor and a Constant Power Load , 2014, 2014 IEEE Transportation Electrification Conference and Expo (ITEC).

[3]  Babak Nahid-Mobarakeh,et al.  Active Stabilization of DC Microgrids Without Remote Sensors for More Electric Aircraft , 2013, IEEE Transactions on Industry Applications.

[4]  Seung-Ki Sul,et al.  Optimal Design of a Damped Input Filter Based on a Genetic Algorithm for an Electrolytic Capacitor-less Converter , 2009 .

[5]  Milijana Odavic,et al.  Analysis of stability aspects of a large constant power load in a local grid , 2013, 2013 15th European Conference on Power Electronics and Applications (EPE).

[6]  Benoit Robyns,et al.  Protection of local high voltage DC regenerative network on MEA , 2013, 2013 15th European Conference on Power Electronics and Applications (EPE).

[7]  A Kwasinski,et al.  Dynamic Behavior and Stabilization of DC Microgrids With Instantaneous Constant-Power Loads , 2011, IEEE Transactions on Power Electronics.

[8]  H. Mokhtari,et al.  Stabilization of DC microgrids with constant-power loads by an active damping method , 2013, 4th Annual International Power Electronics, Drive Systems and Technologies Conference.

[9]  Wei Zhang,et al.  Stability Criteria for Constant Power Loads With Multistage $LC$ Filters , 2011, IEEE Transactions on Vehicular Technology.

[10]  Qiang Tong,et al.  Impedance Stability Criterion of Complex Connected DC Distributed Power System , 2013 .

[11]  Babak Nahid-Mobarakeh,et al.  Distributed Active Resonance Suppression in Hybrid DC Power Systems Under Unbalanced Load Conditions , 2013, IEEE Transactions on Power Electronics.

[12]  Bo Wahlberg,et al.  Stabilization of Induction Motor Drives With Poorly Damped Input Filters , 2007, IEEE Transactions on Industrial Electronics.

[13]  Babak Nahid-Mobarakeh,et al.  Dynamic Consideration of DC Microgrids With Constant Power Loads and Active Damping System—A Design Method for Fault-Tolerant Stabilizing System , 2014, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[14]  Scott D. Sudhoff,et al.  Estimating Regions of Asymptotic Stability of Power Electronics Systems Using Genetic Algorithms , 2010, IEEE Transactions on Control Systems Technology.

[15]  Ali Emadi,et al.  Constant power loads and negative impedance instability in automotive systems: definition, modeling, stability, and control of power electronic converters and motor drives , 2006, IEEE Transactions on Vehicular Technology.