Impact of voltage sourced converter-based back-to-back on the coordination between generator distance phase backup protection and generator steady-state overexcited capability limit

In this paper, investigations carried out to explore the impact of a voltage sourced converter-based back-to-back on the performance of generator distance phase backup protection as well as on the coordination between such a protection and the generator overexcited steady-state capability limit. The voltage sourced converter-based back-to-back is installed to connect a weak and a strong systems. The results of the investigations show that the back-to-back has an adverse effect on the performance of generator distance phase backup protection. Such an impact varies according to the fault type, its location and the generator loading. Moreover, this adverse impact extends to affect the coordination between the generator distance phase backup protection and the generator overexcited steady-state capability limit. The dynamic simulations of a test benchmark are conducted using the PSCAD/EMTDC software.

[1]  R.K. Aggarwal,et al.  Performance evaluation of a distance relay as applied to a transmission system with UPFC , 2006, IEEE Transactions on Power Delivery.

[2]  S.O. Faried,et al.  Supplemental control of voltage sourced converter-based back-to-back for damping subsynchronous resonance , 2009, 2009 IEEE Power & Energy Society General Meeting.

[3]  T.S. Sidhu,et al.  Performance Comparison of Distance Protection Schemes for Shunt-FACTS Compensated Transmission Lines , 2007, IEEE Transactions on Power Delivery.

[4]  M. Bajpai,et al.  Performance of Generator protection during major system disturbances , 2004, IEEE Transactions on Power Delivery.

[5]  Ganapati Panda,et al.  Digital protection of power transmission lines in the presence of series connected FACTS devices , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[6]  Mojtaba Khederzadeh,et al.  TCSC impact on communication-aided distance-protection schemes and its mitigation , 2005 .

[7]  T.S. Sidhu,et al.  Performance of distance relays on shunt-FACTS compensated transmission lines , 2005, IEEE Transactions on Power Delivery.

[8]  G. Joos,et al.  Operation of Impedance Protection Relays with the STATCOm , 2002, IEEE Power Engineering Review.

[9]  M. Noroozian,et al.  The Potential Use of Voltage-Sourced Converter-Based Back-to-Back Tie in Load Restorations , 2002, IEEE Power Engineering Review.

[10]  D. Tziouvaras Relay Performance During Major System Disturbances , 2007, 2007 60th Annual Conference for Protective Relay Engineers.

[11]  Jung-Uk Lim,et al.  A refined Differential Current Protection Method in the FACTS-compensated line , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[12]  Laszlo Gyugyi,et al.  Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems , 1999 .

[13]  C. Mozina Power plant protection and control strategies for blackout avoidance , 2006, 59th Annual Conference for Protective Relay Engineers, 2006..

[14]  Ganapati Panda,et al.  Distance protection in the presence of unified power flow controller , 2000 .

[15]  Walter Elmore,et al.  Protective Relaying Theory And Applications , 1994 .

[16]  Ganapati Panda,et al.  Adaptive relay setting for flexible AC transmission systems (FACTS) , 2000 .

[17]  Donald Reimert Protective Relaying for Power Generation Systems , 2005 .

[18]  A. Petersson,et al.  Eagle Pass back-to-back tie: a dual purpose application of voltage source converter technology , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).