A linac-based stereotactic irradiation technique of uveal melanoma.

PURPOSE To describe a stereotactic irradiation technique for uveal melanomas performed at a linac, based on a non-invasive eye fixation and eye monitoring system. METHODS For eye immobilization a light source system is integrated in a standard stereotactic mask system in front of the healthy eye: During treatment preparation (computed tomography/magnetic resonance imaging) as well as for treatment delivery, patients are instructed to gaze at the fixation light source. A mini-video camera monitors the pupil center position of the diseased eye. For treatment planning and beam delivery standard stereotactic radiotherapy equipment is used. If the pupil center deviation from a predefined 'zero-position' exceeds 1 mm (for more than 2 s), treatment delivery is interrupted. Between 1996 and 1999 60 patients with uveal melanomas, where (i) tumor height exceeded 7 mm, or (ii) tumor height was more than 3 mm, and the central tumor distance to the optic disc and/or the macula was less than 3 mm, have been treated. A total dose of 60 or 70 Gy has been given in 5 fractions within 10 days. RESULTS The repositioning accuracy in the mask system is 0.47+/-0.36 mm in rostral-occipital direction, 0.75+/-0.52 mm laterally, and 1.12+/-0.96 mm in vertical direction. An eye movement analysis performed for 23 patients shows a pupil center deviation from the 'zero' position<1 mm in 91% of all cases investigated. In a theoretical analysis, pupil center deviations are correlated with GTV 'movements'. For a pupil center deviation of 1 mm (rotation of the globe of 5 degrees ) the GTV is still encompassed by the 80% isodose in 94%. CONCLUSION For treatments of uveal melanomas, linac-based stereotactic radiotherapy combined with a non-invasive eye immobilization and monitoring system represents a feasible, accurate and reproducible method. Besides considerable technical requirements, the complexity of the treatment technique demands an interdisciplinary team continuously dedicated to this task.

[1]  O A Mendiondo,et al.  A precision repeat localization head frame for fractionated stereotactic radiotherapy. , 1997, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[2]  K. Winston,et al.  Linear accelerator as a neurosurgical tool for stereotactic radiosurgery. , 1988, Neurosurgery.

[3]  A. Ertl,et al.  Stereotactic irradiation of uveal melanoma with the Leksell gamma unit. , 1997, Frontiers of radiation therapy and oncology.

[4]  P Gastaud,et al.  Results of proton therapy of uveal melanomas treated in Nice. , 1999, International journal of radiation oncology, biology, physics.

[5]  P Chauvel,et al.  Clinical and technical requirements for proton treatment planning of ocular diseases. The SERAG (South Europe Radiotherapy Group). , 1997, Frontiers of radiation therapy and oncology.

[6]  J. Quivey,et al.  Long-term results of helium ion irradiation of uveal melanoma. , 1990, International journal of radiation oncology, biology, physics.

[7]  R. Pötter,et al.  Ruthenium-106 eye plaque brachytherapy in the conservative treatment of uveal melanoma: evaluation of 175 patients treated with 150 Gy from 1981-1989. , 1997, Frontiers of radiation therapy and oncology.

[8]  P. Finger Radiation therapy for choroidal melanoma. , 1997, Survey of ophthalmology.

[9]  M Bellerive,et al.  Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy. , 1994, International journal of radiation oncology, biology, physics.

[10]  K. Bratengeier,et al.  CT simulation in stereotactic brain radiotherapy--analysis of isocenter reproducibility with mask fixation. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  E. Schuster,et al.  Long-term follow-up of Ru-106/Rh-106 brachytherapy for posterior uveal melanoma , 2000, Graefe's Archive for Clinical and Experimental Ophthalmology.

[12]  R. Sagerman Radiotherapy of Ocular Disease , 1998 .

[13]  Y. Akine,et al.  Fractionated stereotactic radiotherapy for choroidal melanoma. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  W. J. Brown,et al.  Leksell stereotactic radiosurgery in the treatment of eye melanoma. , 1987, Neurological research.

[15]  W. K. Saunders,et al.  Helium ion therapy for choroidal melanoma. , 1983, Archives of ophthalmology.

[16]  D. Char,et al.  Long-term follow-up after uveal melanoma charged particle therapy. , 1997, Transactions of the American Ophthalmological Society.

[17]  A. Ertl,et al.  Suction fixation system for stereotactic radiosurgery of intraocular malignancies. , 1995, Acta neurochirurgica. Supplement.

[18]  F. Alessandrini,et al.  Stereotactic radiosurgery of uveal melanomas: preliminary results with Gamma Knife treatment. , 1995, Stereotactic and functional neurosurgery.

[19]  T L Phillips,et al.  15 years experience with helium ion radiotherapy for uveal melanoma. , 1997, International journal of radiation oncology, biology, physics.

[20]  E. Gragoudas,et al.  A randomized controlled trial of varying radiation doses in the treatment of choroidal melanoma. , 2000, Archives of ophthalmology.

[21]  L. Steiner Radiosurgery : baseline and trends , 1992 .

[22]  H. Stallard Radiotherapy for malignant melanoma of the choroid. , 1966, The British journal of ophthalmology.

[23]  R. Pötter,et al.  Local tumor control and morbidity after one to three fractions of stereotactic external beam irradiation for uveal melanoma. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  S. Logani,et al.  Gamma Knife radiosurgery in the treatment of ocular melanoma. , 1993, Stereotactic and functional neurosurgery.

[25]  L. Verhey,et al.  Anterior segment sparing to reduce charged particle radiotherapy complications in uveal melanoma. , 1997, International journal of radiation oncology, biology, physics.

[26]  A. Ertl,et al.  Suction attachment for stereotactic radiosurgery of intraocular malignancies. , 1994, Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde.

[27]  D. Char,et al.  Ten-year follow-up of helium ion therapy for uveal melanoma. , 1998, American journal of ophthalmology.

[28]  J. Debus,et al.  Stereotactic radiation therapy for malignant choroidal tumors: preliminary, short-term results. , 2000, Ophthalmology.