Lateral shift mapping metrology for X-ray telescope mirrors

Currently, high-resolution X-ray telescope mirrors, such as for the Lynx X-Ray Observatory concept, are measured using a Fizeau interferometer with a cylindrical null corrector. Uncertainties in the null wavefront directly couple into the surface measurement uncertainty, including the axial figure and cone angle variation. We extend the absolute surface metrology method of lateral shift mapping for measuring X-ray telescope mirror segments. Lateral shift mapping involves laterally shifting the surface under test relative to the null to multiple positions. The null wavefront can be extracted from the difference between these shifted measurements, leaving only the surface under test. Accurately extracting quadratic terms of the surface under test requires measuring its tilt during shifting. We will show surface metrology results of optical flats measured by Fizeau-based lateral shift mapping with the required angle measured using an autocollimator and compare these results against a three-flat test. We will show how we plan to extend this method to conical X-ray telescope mirror metrology. The lateral shift mapping method reduces the uncertainty introduced by the cylindrical null, a critical step toward making high-resolution X-ray telescope mirrors.

[1]  E. Bloemhof,et al.  Absolute surface metrology by differencing spatially shifted maps from a phase-shifting interferometer. , 2010, Optics letters.

[2]  Hideyuki Mori,et al.  ASTRO-H Soft X-ray Telescope (SXT) , 2011, Astronomical Telescopes and Instrumentation.

[3]  E E Bloemhof Absolute surface metrology with a phase-shifting interferometer for incommensurate transverse spatial shifts. , 2014, Applied optics.

[4]  Yongxin Sui,et al.  Absolute surface figure testing by shift-rotation method using Zernike polynomials. , 2012, Optics letters.

[5]  J. P. Lehan,et al.  Testing of the mirrors for the Constellation-X spectroscopy x-ray telescope with a refractive null , 2007, SPIE Optical Engineering + Applications.

[6]  Kai-Wing Chan,et al.  High-resolution, lightweight, and low-cost x-ray optics for the Lynx observatory , 2019, Journal of Astronomical Telescopes, Instruments, and Systems.

[7]  Marcos Bavdaz,et al.  X-ray testing of silicon pore optics , 2019, Optics for EUV, X-Ray, and Gamma-Ray Astronomy IX.

[8]  J. Schwider,et al.  IV Interferometric Testing of Smooth Surfaces , 1976 .

[9]  William W. Zhang,et al.  Analysis of the NGXO telescope x-ray Hartmann data , 2018, Astronomical Telescopes + Instrumentation.

[10]  Bin Liu,et al.  Absolute calibration of a spherical reference surface for a Fizeau interferometer with the shift-rotation method of iterative algorithm , 2013 .

[11]  W. W. Zhang,et al.  Progress toward a complete metrology set for the International X-ray Observatory (IXO) soft x-ray mirrors , 2009, Optical Engineering + Applications.

[12]  Peter Z. Takacs,et al.  Vertical scanning long trace profiler: a tool for metrology of x-ray mirrors , 1997, Optics & Photonics.

[13]  U. Griesmann Three-flat test solutions based on simple mirror symmetry. , 2006, Applied optics.

[14]  R. Chase,et al.  Design Parameters of Paraboloid-Hyperboloid Telescopes for X-ray Astronomy. , 1972, Applied optics.

[15]  Martin C. Weisskopf,et al.  Full-shell x-ray optics development at NASA Marshall Space Flight Center , 2019, Journal of astronomical telescopes, instruments, and systems.

[16]  Vincenzo Cotroneo,et al.  Measuring the performance of adjustable x-ray optics with wavefront sensing , 2014, Astronomical Telescopes and Instrumentation.

[17]  William W. Zhang,et al.  Lynx X-Ray Observatory: an overview , 2019, Journal of Astronomical Telescopes, Instruments, and Systems.

[18]  Mark L. Schattenburg,et al.  Metrology of thin transparent optics using Shack-Hartmann wavefront sensing , 2004 .

[19]  Peter Z. Takacs,et al.  Calibration of a vertical-scan long trace profiler at MSFC , 2001, Optics + Photonics.