Pulsatile flow phantom for ultrasound image-guided HIFU treatment of vascular injuries.

A pulsatile flow phantom was developed for studies of ultrasound image-guided high intensity focused ultrasound (HIFU) application in transcutaneous hemostasis of injured blood vessels. The flow phantom consisted of a pulsatile pump system with instrumented excised porcine carotid artery, which was imbedded in a transparent agarose gel to model structural configuration of in vivo tissues. Heparinized porcine blood was circulated through the phantom. The artery was injured using an 18-gauge needle to model a penetrating injury in human peripheral vasculature. A HIFU transducer with the diameter of 7 cm, focal length of 6.3 cm and frequency of 3.4 MHz was used to seal the puncture. Ultrasound imaging was used to localize and target the puncture site and to monitor the HIFU treatment. Triphasic blood flows present in the human arteries were reproduced, with flow rates of 50 to 500 mL/min, pulse rates of 62 to 138 beats/min and peak pressures of 100 to 250 mm Hg. The penetrating injury of an artery was mimicked successfully in the flow phantom setting and was easily visualized both optically through the transparent gel and with power Doppler ultrasound imaging. Hemostasis was achieved in 55 +/- 31 s (n = 9) of HIFU application. Histologic observations showed that a HIFU-sealed puncture was filled with clotted blood and covered with a fibrin cap. The pulsatile flow phantom provides a controlled and repeatable environment for studies of transcutaneous image-guided HIFU application in hemostasis of a variety of blood vessel injuries.

[1]  C. R. Hill,et al.  Histological changes in rat liver tumours treated with high-intensity focused ultrasound. , 1993, Ultrasound in medicine & biology.

[2]  Vesna Zderic,et al.  Gel phantom for use in high-intensity focused ultrasound dosimetry. , 2005, Ultrasound in medicine & biology.

[3]  J. Polak,et al.  Arterial injuries: a sonographic approach. , 2004, Radiologic clinics of North America.

[4]  R. Martin,et al.  Hemostasis of punctured vessels using Doppler-guided high-intensity ultrasound. , 1999, Ultrasound in medicine & biology.

[5]  G. Dangas,et al.  Vascular Closure Devices , 2005, American journal of cardiovascular drugs : drugs, devices, and other interventions.

[6]  V. Humphrey,et al.  The cooling effect of liquid flow on the focussed ultrasound-induced heating in a simulated foetal brain. , 2003, Ultrasound in medicine & biology.

[7]  K. Cherry,et al.  Iatrogenic operative injuries of abdominal and pelvic veins: a potentially lethal complication. , 2004, Journal of vascular surgery.

[8]  K. Shung,et al.  Ultrasonic backscattering from porcine whole blood of varying hematocrit and shear rate under pulsatile flow. , 1999, Ultrasound in medicine & biology.

[9]  Vesna Zderic,et al.  Detection of Bleeding in Injured Femoral Arteries With Contrast‐Enhanced Sonography , 2006, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[10]  A. Fenster,et al.  A geometrically accurate vascular phantom for comparative studies of x-ray, ultrasound, and magnetic resonance vascular imaging: construction and geometrical verification. , 1993, Medical physics.

[11]  L A Crum,et al.  Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging. , 2001, Ultrasound in medicine & biology.

[12]  F. Cole,et al.  Newer diagnostic modalities for vascular injuries: the way we were, the way we are. , 2001, The Surgical clinics of North America.

[13]  Alec C Beekley,et al.  Extremity vascular injuries on the battlefield: tips for surgeons deploying to war. , 2006, The Journal of trauma.

[14]  J. Hunt,et al.  Duplex ultrasonography versus arteriography in the diagnosis of arterial injury: an experimental study. , 1992, Journal of Trauma.

[15]  Roy W. Martin,et al.  Hemorrhage control in arteries using high-intensity focused ultrasound: a survival study. , 2006, Ultrasonics.

[16]  M. Caps The epidemiology of vascular trauma. , 1998, Seminars in vascular surgery.

[17]  J. Niles,et al.  Anticoagulation in continuous renal replacement therapy. , 1999, Current opinion in nephrology and hypertension.

[18]  R. Martin,et al.  Hemostasis of punctured blood vessels using high-intensity focused ultrasound. , 1998, Ultrasound in medicine & biology.

[19]  G. Velmahos,et al.  Angiographic Embolization of Bilateral Internal Iliac Arteries to Control Life-Threatening Hemorrhage after Blunt Trauma to the Pelvis , 2000, The American surgeon.

[20]  D. A. Christopher,et al.  A wall-less vessel phantom for Doppler ultrasound studies. , 1995, Ultrasound in medicine & biology.

[21]  Shahram Vaezy,et al.  Therapeutic Ultrasound, Part II * . High Intensity Focused Ultrasound: A Method of Hemostasis , 2001, Echocardiography.

[22]  H. Cardinal,et al.  A real vessel phantom for flow imaging: 3-D Doppler ultrasound of steady flow. , 2001, Ultrasound in medicine & biology.

[23]  P. Rhee,et al.  An historical tour of vascular injury management: from its inception to the new millennium. , 2001, The Surgical clinics of North America.

[24]  Per Ask,et al.  Accuracy of spectral Doppler flow and tissue velocity measurements in ultrasound systems. , 2004, Ultrasound in medicine & biology.

[25]  J B Fowlkes,et al.  Analysis of refill curve shape in ultrasound contrast agent studies. , 2004, Medical physics.

[26]  R. Rydman,et al.  A case-control study of risk factors that predict femoral arterial injury in penetrating thigh trauma. , 1994, Annals of emergency medicine.

[27]  R S Cobbold,et al.  On the design and evaluation of a steady flow model for Doppler ultrasound studies. , 1989, Ultrasound in medicine & biology.

[28]  L. Magnotti,et al.  Angiographic embolization for liver injuries: low mortality, high morbidity. , 2003, The Journal of trauma.

[29]  Nonstenotic internal carotid arteries: effects of age and blood pressure at the time of scanning on Doppler US velocity measurements. , 2001, Radiology.

[30]  K V Ramnarine,et al.  Validation of a new blood-mimicking fluid for use in Doppler flow test objects. , 1998, Ultrasound in medicine & biology.

[31]  T. Scalea,et al.  Interventional techniques in vascular trauma. , 2001, The Surgical clinics of North America.

[32]  Hristo N Nikolov,et al.  An in vitro system for Doppler ultrasound flow studies in the stenosed carotid artery bifurcation. , 2002, Ultrasound in medicine & biology.

[33]  A Fenster,et al.  A real vessel phantom for imaging experimentation. , 1997, Medical physics.