Measurement of the ultrasonic properties of vascular tissues and blood from 35-65 MHz.

A 50 MHz ultrasound backscatter microscope has been built to measure the acoustic properties of vascular tissues and blood over the frequency range from 35-65 MHz. High resolution (45 microns) ultrasound backscatter microscope images of nine femoral and eight common carotid human artery samples were made and compared with corresponding histological sections. Individual tissue layers were selected using these images for quantitative measurement of the frequency dependent backscatter. Backscatter measurements were made in each layer of an artery at two different angles of incidence: along the axis of the artery (axial direction) and at 90 degrees to this measurement radially out from the center of the artery (radial direction). Scattering was found to be higher in elastic arteries (carotid) than in the muscular arteries (femoral). The largest difference was found in the media where the average scatter (measured in the radial direction at 50 MHz) increased from 0.002 sr-1 mm-1 in muscular arteries to 0.4 sr-1 mm-1 in elastic arteries. Large differences in scattering between measurements made in the axial and radial direction were also found. Again, the largest differences were found in the media where scattering (at 50 MHz) in carotid arteries increased from 0.003 sr-1 mm-1 measured in the axial direction to 0.4 sr-1 mm-1 measured in the radial direction. The speed of sound and attenuation in the artery wall of each sample were measured. Speed of sound measurements were found to range between 1579-1628 ms-1. The average attenuation in the artery wall increased from 4 dB mm-1 at 30 MHz to 10 dB mm-1 at 60 mHz. This is higher than the attenuation measured in blood which increased from 1.6 dB mm-1 to 5 dB mm-1 over the same frequency range. The backscatter coefficient for flowing blood was measured for flow velocities up to 36 cms-1. At flow velocities below 18 cms-1 a level of scattering of 0.0005 sr-1 mm-1 (at 50 MHz) was found. An increase in scattering of 1.6 times was measured when the flow velocity was increased to 36 cms-1. All measurements were made at 37 degrees C. The relevance of these results to clinical imaging and image interpretation is discussed.

[1]  C T Lancée,et al.  Arterial wall characteristics determined by intravascular ultrasound imaging: an in vitro study. , 1989, Journal of the American College of Cardiology.

[2]  W. Roberts,et al.  Plaque Characterization of Atherosclerotic Coronary Arteries by Intravascular Ultrasound , 1990, Echocardiography.

[3]  F. Dunn,et al.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. , 1978, The Journal of the Acoustical Society of America.

[4]  H. Goldsmith,et al.  Rheological Aspects of Thrombosis and Haemostasis: Basic Principles and Applications , 1986, Thrombosis and Haemostasis.

[5]  J. G. Miller,et al.  Quantitative ultrasonic characterization of the nature of atherosclerotic plaques in human aorta. , 1987, Circulation research.

[6]  M. Osteaux,et al.  Tissue Characterization of Atheromatous Plaques: Correlation Between Ultrasound Image and Histological Findings , 1990, Journal of clinical ultrasound : JCU.

[7]  A J Tajik,et al.  Intravascular ultrasound imaging: in vitro validation and pathologic correlation. , 1990, Journal of the American College of Cardiology.

[8]  K. Shung,et al.  Echoicity of whole blood. , 1989, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[9]  Paul G. Yock,et al.  Intravascular Two-Dimensional Catheter Ultrasound: Clinical Studies In The Periphery , 1989, Photonics West - Lasers and Applications in Science and Engineering.

[10]  C. Grines,et al.  Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography. , 1990, Circulation.

[11]  J. Tarbell,et al.  Effect of flow disturbance on ultrasonic backscatter from blood. , 1984, The Journal of the Acoustical Society of America.

[12]  N G Pandian,et al.  Ultrasound angioscopy: real-time, two-dimensional, intraluminal ultrasound imaging of blood vessels. , 1988, The American journal of cardiology.

[13]  N Bom,et al.  Intra-arterial ultrasonic imaging for recanalization by spark erosion. , 1988, Ultrasound in medicine & biology.

[14]  E. H. Chiang,et al.  Feasibility of high-resolution, intravascular ultrasonic imaging catheters. , 1988, Radiology.

[15]  John M. Reid,et al.  Scattering of Ultrasound by Blood , 1976, IEEE Transactions on Biomedical Engineering.

[16]  N Bom,et al.  Angle-dependent backscatter from the arterial wall. , 1991, Ultrasound in medicine & biology.

[17]  F. Foster,et al.  Frequency dependence of ultrasound attenuation and backscatter in breast tissue. , 1986, Ultrasound in medicine & biology.

[18]  F. Foster,et al.  The Ultrasound Macroscope: Initial Studies of Breast Tissue , 1984 .

[19]  J. Griffith,et al.  Assessment of normal and atherosclerotic arterial wall thickness with an intravascular ultrasound imaging catheter. , 1990, American heart journal.

[20]  M. Wolverson,et al.  Ultrasonic tissue characterization of atheromatous plaques using a high resolution real time scanner. , 1983, Ultrasound in medicine & biology.

[21]  B. Sigel,et al.  Red cell aggregation as a cause of blood-flow echogenicity. , 1983, Radiology.

[22]  P. Yock,et al.  Intravascular ultrasound: significance of the three-layered appearance of normal muscular arteries , 1990 .

[23]  M. Leon,et al.  An in vivo feasibility study of intravascular ultrasound imaging. , 1989, American journal of surgery.

[24]  Craig J. Hartley,et al.  Intravascular Imaging With Ultrasound , 1988, Photonics West - Lasers and Applications in Science and Engineering.

[25]  L Landini,et al.  Evaluation of frequency dependence of backscatter coefficient in normal and atherosclerotic aortic walls. , 1986, Ultrasound in medicine & biology.

[26]  W. Roberts,et al.  Coronary artery imaging with intravascular high-frequency ultrasound. , 1990, Circulation.

[27]  J.W. Hunt,et al.  The design of protection circuitry for high-frequency ultrasound imaging systems , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  J. M. Gessert,et al.  Display Considerations For Intravascular Ultrasonic Imaging , 1989, Photonics West - Lasers and Applications in Science and Engineering.

[29]  F. Foster,et al.  The Design and Fabrication of High Frequency Poly(Vinylidene Fluoride) Transducers , 1989 .