High throughput liquid chromatography with sub-2 microm particles at high pressure and high temperature.

In this study, ultra performance liquid chromatography (UPLC) using pressures up to 1,000 bar and columns packed with sub-2 microm particles has been combined with high temperature mobile phase conditions (up to 90 degrees C). By using high temperature ultra performance liquid chromatography (HT-UPLC), it is possible to drastically decrease the analysis time without loss in efficiency. The stability and chromatographic behavior of sub-2 microm particles were evaluated at high temperature and high pressure. The chromatographic support remained stable after 500 injections (equivalent to 7,500 column volumes) and plate height curves demonstrated the capability of HT-UPLC to obtain fast separations. For example, a separation of nine doping agents was performed in less than 1 min with sub-2 microm particles at 90 degrees C. Furthermore, a shorter column (30 mm length) was used and allowed a separation of eight pharmaceutical compounds in only 40s.

[1]  C. Horváth,et al.  Rapid peptide mapping by high-performance liquid chromatography. , 1988, Journal of chromatography.

[2]  I. Wilson Investigation of a range of stationary phases for the separation of model drugs by HPLC using superheated water as the mobile phase , 2000 .

[3]  John G. Dorsey,et al.  Equations for calculation of chromatographic figures of merit for ideal and skewed peaks , 1983 .

[4]  Robert S Plumb,et al.  Generation of ultrahigh peak capacity LC separations via elevated temperatures and high linear mobile-phase velocities. , 2006, Analytical chemistry.

[5]  L. Snyder,et al.  Combined use of temperature and solvent strength in reversed-phase gradient elution. I. Predicting separation as a function of temperature and gradient conditions. , 1996, Journal of chromatography. A.

[6]  E. Katz,et al.  Use of chromatographic data to determine the molecular weight of a solute eluted from a liquid chromatographic column , 1983 .

[7]  S. Heinisch,et al.  Effect of temperature on the retention of ionizable compounds in reversed-phase liquid chromatography: application to method development. , 2006, Journal of chromatography. A.

[8]  J. Dolan,et al.  Reversed-phase separation of achiral isomers by varying temperature and either gradient time or solvent strength. , 2000, Journal of chromatography. A.

[9]  D. Guillarme,et al.  Effect of temperature in reversed phase liquid chromatography. , 2004, Journal of chromatography. A.

[10]  U. Neue,et al.  Ultrafast liquid chromatography/ultraviolet and liquid chromatography/tandem mass spectrometric analysis. , 2001, Rapid communications in mass spectrometry : RCM.

[11]  R. Scott,et al.  The Design of Column Connection Tubes for Liquid Chromatography , 1971 .

[12]  C. Horváth,et al.  High-speed high-performance liquid chromatography of peptides and proteins. , 1995, Journal of chromatography. A.

[13]  P. Sandra,et al.  Elevated temperature and temperature programming in conventional liquid chromatography--fundamentals and applications. , 2006, Journal of separation science.

[14]  J. Veuthey,et al.  Fast analysis in liquid chromatography using small particle size and high pressure. , 2006, Journal of separation science.

[15]  Milton L. Lee,et al.  Elevated-temperature ultrahigh-pressure liquid chromatography using very small polybutadiene-coated nonporous zirconia particles. , 2003, Journal of chromatography. A.

[16]  P. Carr,et al.  Effect of temperature on the thermodynamic properties, kinetic performance, and stability of polybutadiene-coated zirconia. , 1997, Analytical chemistry.

[17]  L. Snyder,et al.  Selectivity differences for C18 and C8 reversed-phase columns as a function of temperature and gradient steepness. I. Optimizing selectivity and resolution. , 2000, Journal of chromatography. A.

[18]  M. Lee,et al.  Practical aspects of ultrahigh pressure capillary liquid chromatography. , 2001, Journal of chromatography. A.

[19]  J. Giddings Comparison of Theoretical Limit of Separating Speed in Gas and Liquid Chromatography. , 1965 .

[20]  E. Lesellier,et al.  Use of optimization software for comparing stationary phases in order to find HPLC conditions suitable for separating 16 PAHs , 2000 .

[21]  J. Knox,et al.  Kinetic Conditions for Optimum Speed and Resolution in Column Chromatography , 1969 .

[22]  K. Thompson,et al.  Evaluation of a C18 hybrid stationary phase using high-temperature chromatography , 2005 .

[23]  G. Guiochon,et al.  Effects of high pressure in liquid chromatography. , 2005, Journal of chromatography. A.

[24]  H. Mcnair,et al.  Temperature Programmed Microbore HPLC—Part I , 1984 .

[25]  J. Veuthey,et al.  Practical constraints in the kinetic plot representation of chromatographic performance data: theory and application to experimental data. , 2006, Analytical chemistry.

[26]  Milton L. Lee,et al.  Fast ultrahigh‐pressure liquid chromatography: On‐column UV and time‐of‐flight mass spectrometric detection , 1999 .

[27]  Milton L. Lee,et al.  Synthesis of micron diameter polybutadiene-encapsulated non-porous zirconia particles for ultrahigh pressure liquid chromatography. , 2003, Journal of chromatography. A.

[28]  P. Sandra,et al.  Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1mm I.D. columns. , 2006, Journal of chromatography. A.

[29]  J. Knox Practical Aspects of LC Theory , 1977 .

[30]  F. Antia,et al.  High-performance liquid chromatography at elevated temperatures: examination of conditions for the rapid separation of large molecules , 1988 .

[31]  J. Jorgenson,et al.  Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns. , 1997, Analytical chemistry.

[32]  C. Horváth,et al.  Temperature programming and gradient elution in reversed-phase chromatography with packed capillary columns. , 1997, Journal of chromatography. A.

[33]  C. Wilke,et al.  Correlation of diffusion coefficients in dilute solutions , 1955 .

[34]  J. S. Brown,et al.  High-temperature ultrafast liquid chromatography. , 2000, Analytical chemistry.

[35]  D. Maynes,et al.  Safety concerns in ultrahigh pressure capillary liquid chromatography using air-driven pumps. , 2003, Journal of chromatography. A.

[36]  P. Carr,et al.  A study of the efficiency of polybutadiene-coated zirconia as a reversed-phase chromatographic support. , 1997, Analytical chemistry.

[37]  D. Clicq,et al.  Use of the kinetic plot method to analyze commercial high-temperature liquid chromatography systems. I: Intrinsic performance comparison. , 2007, Journal of chromatography. A.

[38]  P. Carr,et al.  Evaluation of temperature effects on selectivity in RPLC separations using polybutadiene-coated zirconia. , 1997, Analytical chemistry.

[39]  J. Veuthey,et al.  Chromatographic behaviour and comparison of column packed with sub-2 microm stationary phases in liquid chromatography. , 2006, Journal of chromatography. A.

[40]  J. Dolan,et al.  Simultaneous variation of temperature and gradient steepness for reversed-phase high-performance liquid chromatography method development. II. The use of further changes in conditions. , 1998, Journal of chromatography. A.