Cone Beam Computed Tomography in the Analysis of Endodontic Treatment of Teeth (in an Experiment)

Objective. To determine peculiarities when using microfocus cone beam computed tomography (micro-CBCT) and cone beam computed tomography (CBCT) to analyze the anatomy of the teeth and the quality of endodontic treatment.Material and methods. Micro-CBCT and CBCT were experimentally used to examine 8 extracted tooth preparations before and after endodontic root canal treatment using different types of filling material.Results. Micro-CBCT showed the high informative value of determining the type, nature, and quality of canal filling and diagnosed many cracks and accessory canals. According to the micro-CBCT findings, the tooth apexes were not filled; the lumen of the canals was unevenly and loosely filled with endodontic material; the passages of guttapercha points were well traced; the nature of the endodontic material was differentiated.Conclusion. Micro-CBCT opens up new opportunities in dentistry with tooth volume visualization, allowing the minor and low-contrast details of the anatomical structure of the teeth to be seen on the X-ray image.

[1]  A. Kulikova,et al.  Modern approaches to the elimination of artifacts of cone-beam computed tomography of the maxillofacial region , 2021, Medical alphabet.

[2]  А. Ю. Васильев,et al.  КОНУСНО-ЛУЧЕВАЯ КОМПЬЮТЕРНАЯ ТОМОГРАФИЯ В ПАЛЕОАНТРОПОЛОГИИ , 2016 .

[3]  A. А. Зубарева,et al.  ВОЗМОЖНОСТИ КОНУСНО-ЛУЧЕВОЙ КОМПЬЮТЕРНОЙ ТОМОГРАФИИ В ОЦЕНКЕ ХИРУРГИЧЕСКИ ЗНАЧИМЫХ АНТРОПОМЕТРИЧЕСКИХ ПОКАЗАТЕЛЕЙ СТРУКТУР СРЕДНЕГО УХА ПРИ РАЗЛИЧНЫХ ТИПАХ СТРОЕНИЯ ВИСОЧНОЙ КОСТИ , 2014 .

[4]  Юрий Александрович Васильев Сравнительная оценка точности объема корневого канала зубов с помощью томографических методик исследования в эксперименте , 2014 .

[5]  R. Müller,et al.  Diagnostic value of micro-CT in comparison with histology in the qualitative assessment of historical human skull bone pathologies. , 2007, American journal of physical anthropology.

[6]  S. Brooks,et al.  Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. , 2006, Dento maxillo facial radiology.

[7]  A. Olejniczak,et al.  Assessment of the accuracy of dental enamel thickness measurements using microfocal X-ray computed tomography. , 2006, The anatomical record. Part A, Discoveries in molecular, cellular, and evolutionary biology.

[8]  Е Н Жулев,et al.  Сравнительная оценка точности оттисков для ортопедического лечения дефектов твердых тканей зубов искусственными коронками , 2015 .

[9]  Array А. Комарова,et al.  Сравнительная оценка информативности критериев выявления гипертрофии миокарда левого желудочка методом классической электрокардиографии у пациентов с артериальной гипертонией , 2006 .