Energetic and exergetic efficiencies of coal-fired CHP (combined heat and power) plants used in district heating systems of China

The efficiencies of coal-fired CHP (combined heat and power) plants used in the district heating systems of China were analyzed with a thermodynamic model in the Hysys program. The influences of four parameters were evaluated by the Taguchi method. The results indicated that the extraction steam flow rate and extraction steam pressure are the most important parameters for energetic and exergetic efficiencies, respectively. The relations between extraction steam flow rate, extraction steam pressure and the energetic and exergetic efficiencies were investigated. The energetic and exergetic efficiencies were compared to the RPES (relative primary energy savings) and the RAI (relative avoided irreversibility). Compared to SHP (separate heat and power) generation, the CHP systems save fuel energy when extraction ratio is larger than 0.15. In the analysis of RAI, the minimum extraction ratio at which CHP system has advantages compared with SHP varies between 0.25 and 0.6. The higher extraction pressure corresponds to a higher value. Two of the examined plants had design conditions giving RPES close to zero and negative RAI. The third had both positive RPES and RAI at design conditions. The minimum extraction ratio can be used as an indicator to design or choose CHP plant for a given district heating system.

[1]  Isam H. Aljundi,et al.  Energy and exergy analysis of a steam power plant in Jordan , 2009 .

[2]  R. Roy A Primer on the Taguchi Method , 1990 .

[3]  Liejin Guo,et al.  Hydrogen production by supercritical water gasification of biomass: Explore the way to maximum hydrogen yield and high carbon gasification efficiency , 2012 .

[4]  Chen Jing-kun,et al.  Analysis on Design Standards for Energy Efficiency of Residential Buildings in Severe Cold and Cold Zones(JGJ26-2010) , 2012 .

[5]  Y. M. Shi,et al.  Sensitivity analysis of energy demands on performance of CCHP system , 2008 .

[6]  Ibrahim Dincer,et al.  Efficiency analysis of a cogeneration and district energy system , 2005 .

[7]  J H Horlock,et al.  Thermodynamic Availability and its Application to Combined Heat and Power Plant , 1985 .

[8]  Antonio Piacentino,et al.  Cogeneration: a regulatory framework toward growth , 2005 .

[9]  Ivar S. Ertesvåg,et al.  Exergy analysis of a steam production and distribution system including alternatives to throttling and the single pressure steam production , 2011 .

[10]  Ibrahim Dincer,et al.  Energetic and exergetic performance analyses of a combined heat and power plant with absorption inlet cooling and evaporative aftercooling , 2011 .

[11]  Svein J. Nesheim,et al.  Efficiencies and indicators defined to promote combined heat and power , 2007 .

[12]  J. Gallagher,et al.  NBS/NRC Steam Tables: Thermodynamic and Transport Properties and Computer Programs for Vapor and Liquid States of Water in SI Units, , 1984 .

[13]  Alok Srivastava Second law (exergy) analysis of various types of coal , 1988 .

[14]  Suleyman Hakan Sevilgen,et al.  Thermodynamic analysis of an existing coal-fired power plant for district heating/cooling application , 2010 .

[15]  Enrico Sciubba COGENERATION PLANT FOR CATHOLIC UNIVERSITY OF AMERICA: A CASE STUDY. , 1985 .

[16]  Ivar S. Ertesvåg,et al.  Exergetic comparison of efficiency indicators for combined heat and power (CHP) , 2007 .

[17]  Jan Szargut,et al.  Exergy Analysis of Thermal, Chemical, and Metallurgical Processes , 1988 .

[18]  Ali Keshavarz,et al.  Energy and exergy analyses of a micro-steam CCHP cycle for a residential building , 2012 .

[19]  H. H. Erdem,et al.  Comparative energetic and exergetic performance analyses for coal-fired thermal power plants in Turkey , 2009 .

[20]  I Dincer,et al.  Exergetic analysis of cogeneration-based district energy systems , 2004 .

[21]  Horng-Wen Wu,et al.  Combustion characteristics and optimal factors determination with Taguchi method for diesel engines port-injecting hydrogen , 2012 .

[22]  A. Ghamarian,et al.  Exergy analysis of Illinois No. 6 coal , 1982 .

[23]  Massimo Dentice d’Accadia,et al.  Engineering analysis of uncertainties in the performance evaluation of CHP systems , 2011 .

[24]  R Lowe Combined heat and power considered as a virtual steam cycle heat pump , 2011 .

[25]  Shyi-Min Lu,et al.  Optimum design of natural-circulation solar-water-heater by the Taguchi method , 2003 .

[26]  Gyung-Jin Park,et al.  An optimization algorithm using orthogonal arrays in discrete design space for structures , 2003 .

[27]  Olav Bolland,et al.  Exergy analysis of a gas-turbine combined-cycle power plant with precombustion CO2 capture , 2005 .

[28]  E Bilgen,et al.  Exergetic and engineering analyses of gas turbine based cogeneration systems , 2000 .

[29]  Marco Badami,et al.  Exergetic analysis of an innovative small scale combined cycle cogeneration system , 2010 .

[30]  T. J. Kotas,et al.  The Exergy Method of Thermal Plant Analysis , 2012 .