Temperature compensation of fluorescence intensity-based fiber-optic oxygen sensors using modified Stern–Volmer model

Abstract In practical sensing applications, temperature effects are of particular concern, and hence it is necessary to develop the means to correct the fluorescence intensity measurement in accordance with the working temperature. Accordingly, this study develops a modified Stern–Volmer model to compensate for the temperature drift of oxygen concentration measurements obtained using fiber-optic sensors. The oxygen sensors considered in this study are based on teraethylorthosilane (TEOS)/ n -octyltriethoxysilane (Octyl-triEOS) or n -propyltrimethoxysilane ( n -propyl-TriMOS)/3,3,3-trifluoropropyltrimethoxysilane (TFP-TriMOS) composite xerogels doped with platinum meso-tetrakis(pentafluorophenyl)porphine (PtTFPP). The experimental results are fitted to the modified Stern–Volmer model in order to compute suitable values for a temperature compensation coefficient at different working temperatures. It is found that the proposed temperature compensation method reduces the difference in the oxygen concentration measurement for working temperatures in the range of 25–70 °C as compared to data without compensation. The linearity and sensitivity of PtTFPP-doped n -propyl-TriMOS/TFP-TriMOS sensor are better than PtTFPP-doped TEOS/Octyl-triEOS sensor for working temperatures in the range of 25–70 °C. The proposed approach could provide a straightforward and effective means of improving the accuracy of fiber-optic oxygen sensors if a variable attenuator is designed according to the temperature compensation coefficient. Thus, the fiber-optic oxygen sensor with a variable attenuator could work in a broad temperature range without using a temperature sensor.

[1]  S. Lehrer Solute perturbation of protein fluorescence. The quenching of the tryptophyl fluorescence of model compounds and of lysozyme by iodide ion. , 1971, Biochemistry.

[2]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[3]  Benjamin A. DeGraff,et al.  Peer Reviewed: Oxygen Sensors Based on Luminescence Quenching. , 1999 .

[4]  O. Wolfbeis Fiber-optic chemical sensors and biosensors. , 2000, Analytical chemistry.

[5]  Max E. Lippitsch,et al.  Fibre-optic oxygen sensor with the fluorescence decay time as the information carrier , 1988 .

[6]  D. Papkovsky,et al.  Modelling of phase-fluorometric oxygen sensors: Consideration of temperature effects and operational requirements , 2006 .

[7]  M. Gouterman,et al.  Ideality of pressure-sensitive paint. II. Effect of annealing on the temperature dependence of the luminescence , 2000 .

[8]  G. Rao,et al.  Ratio measurements in oxygen determinations: wavelength ratiometry, lifetime discrimination, and polarization detection , 2003 .

[9]  D R Walt,et al.  Improved fiber-optic chemical sensor for penicillin. , 1995, Analytical chemistry.

[10]  A. Neal Watkins,et al.  Portable, Low-Cost, Solid-State Luminescence-Based O2 Sensor , 1998 .

[11]  M. Gouterman,et al.  Ideality of pressure-sensitive paint. IV. Improvement of luminescence behavior by addition of pigment , 2000 .

[12]  Alfredo Sanz-Medel,et al.  Dual emission probe for luminescence oxygen sensing: a critical comparison between intensity, lifetime and ratiometric measurements. , 2005, Talanta.

[13]  Ingo Klimant,et al.  Optical Fiber Sensor for Biological Oxygen Demand , 1994 .

[14]  Ichiro Okura,et al.  Photostable Optical Oxygen Sensing Material: Platinum Tetrakis(pentafluorophenyl)porphyrin Immobilized in Polystyrene , 1997 .

[15]  Sergey M Borisov,et al.  Temperature-sensitive europium(III) probes and their use for simultaneous luminescent sensing of temperature and oxygen. , 2006, Analytical chemistry.

[16]  Yu-Lung Lo,et al.  High-performance fiber-optic oxygen sensors based on fluorinated xerogels doped with Pt(II) complexes , 2007 .

[17]  Wenying Xu,et al.  Modeling of Luminescence Quenching-Based Sensors: Comparison of Multisite and Nonlinear Gas Solubility Models , 1995 .

[18]  Benjamin A. DeGraff,et al.  Photophysics and photochemistry of oxygen sensors based on luminescent transition-metal complexes , 1991 .

[19]  K. Tsukada,et al.  Development of catheter-type optical oxygen sensor and applications to bioinstrumentation. , 2003, Biosensors & bioelectronics.

[20]  Dmitry B. Papkovsky Luminescent porphyrins as probes for optical (bio)sensors , 1993 .

[21]  S. K. Lam,et al.  Characterization of phosphorescence oxygen sensor based on erythrosin B in sol–gel silica in wide pressure and temperature ranges , 2001 .

[22]  Raoul Kopelman,et al.  Ratiometric fiber optic sensors for the detection of inter- and intra-cellular dissolved oxygen , 2005 .

[23]  Yu-Lung Lo,et al.  A Plastic Optical Fiber Sensor for the Dual Sensing of Temperature and Oxygen , 2008, IEEE Photonics Technology Letters.

[24]  Ichiro Okura,et al.  Photoluminescent determination of oxygen using metalloporphyrin-polymer sensing systems , 1998 .

[25]  Gerhard A. Holst,et al.  DSP-based measuring system for temperature-compensated fiber optical oxygen sensors , 2002, SPIE Optics East.

[26]  LeeSang-Kyung,et al.  Highly Sensitive Optical Oxygen Sensing Material: Thin Silica Xerogel Doped with Tris(4,7-diphenyl-1,10-phenanthroline)ruthenium , 2001 .

[27]  Yu-Lung Lo,et al.  Highly sensitive optical fiber oxygen sensor using Pt(II) complex embedded in sol-gel matrices , 2006 .

[28]  R. Vandeloise,et al.  Fibre-optic oxygen sensor based on luminescence quenching of a Pt(II) complex embedded in polymer matrices , 1996 .

[29]  J. N. Demas,et al.  Luminescence-based sensors: microheterogeneous and temperature effects☆ , 1993 .