One-Channel Surface Electromyography Decomposition for Muscle Force Estimation

Estimating muscle force by surface electromyography (sEMG) is a non-invasive and flexible way to diagnose biomechanical diseases and control assistive devices such as prosthetic hands. To estimate muscle force using sEMG, a supervised method is commonly adopted. This requires simultaneous recording of sEMG signals and muscle force measured by additional devices to tune the variables involved. However, recording the muscle force of the lost limb of an amputee is challenging, and the supervised method has limitations in this regard. Although the unsupervised method does not require muscle force recording, it suffers from low accuracy due to a lack of reference data. To achieve accurate and easy estimation of muscle force by the unsupervised method, we propose a decomposition of one-channel sEMG signals into constituent motor unit action potentials (MUAPs) in two steps: (1) learning an orthogonal basis of sEMG signals through reconstruction independent component analysis; (2) extracting spike-like MUAPs from the basis vectors. Nine healthy subjects were recruited to evaluate the accuracy of the proposed approach in estimating muscle force of the biceps brachii. The results demonstrated that the proposed approach based on decomposed MUAPs explains more than 80% of the muscle force variability recorded at an arbitrary force level, while the conventional amplitude-based approach explains only 62.3% of this variability. With the proposed approach, we were also able to achieve grip force control of a prosthetic hand, which is one of the most important clinical applications of the unsupervised method. Experiments on two trans-radial amputees indicated that the proposed approach improves the performance of the prosthetic hand in grasping everyday objects.

[1]  Claudio Castellini,et al.  Assessment of a Wearable Force- and Electromyography Device and Comparison of the Related Signals for Myocontrol , 2016, Front. Neurorobot..

[2]  M. Stock,et al.  Motor Unit Interpulse Intervals During High Force Contractions. , 2016, Motor control.

[3]  P. Rousseeuw Silhouettes: a graphical aid to the interpretation and validation of cluster analysis , 1987 .

[4]  A Holobar,et al.  Non-invasive characterization of motor unit behaviour in pathological tremor , 2012, Journal of neural engineering.

[5]  Sergei Vassilvitskii,et al.  k-means++: the advantages of careful seeding , 2007, SODA '07.

[6]  P. Butler,et al.  The University of Texas Medical School at Houston. , 2010, Academic medicine : journal of the Association of American Medical Colleges.

[7]  Dario Farina,et al.  A surface EMG generation model with multilayer cylindrical description of the volume conductor , 2004, IEEE Transactions on Biomedical Engineering.

[8]  Justin Bayer,et al.  Key Insights into Hand Biomechanics: Human Grip Stiffness Can Be Decoupled from Force by Cocontraction and Predicted from Electromyography , 2017, Front. Neurorobot..

[9]  Gea Drost,et al.  A high-density multichannel surface electromyography system for the characterization of single motor units , 2002 .

[10]  Jaap H van Dieën,et al.  Methodological aspects of SEMG recordings for force estimation--a tutorial and review. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[11]  Jaap H van Dieën,et al.  Prediction of handgrip forces using surface EMG of forearm muscles. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[12]  Jun Guo,et al.  The small sample size problem of ICA: A comparative study and analysis , 2012, Pattern Recognit..

[13]  Timothy H. Lucas,et al.  The Virtual Trackpad: An Electromyography-Based, Wireless, Real-Time, Low-Power, Embedded Hand-Gesture-Recognition System Using an Event-Driven Artificial Neural Network , 2017, IEEE Transactions on Circuits and Systems II: Express Briefs.

[14]  Mitsuhiro Hayashibe,et al.  Voluntary EMG-to-force estimation with a multi-scale physiological muscle model , 2013, Biomedical engineering online.

[15]  Franco Tanzi,et al.  Spectral Analysis of Surface Motor Unit Action Potentials and Surface Interference Electromyogram , 1981, IEEE Transactions on Biomedical Engineering.

[16]  Quoc V. Le,et al.  ICA with Reconstruction Cost for Efficient Overcomplete Feature Learning , 2011, NIPS.

[17]  Dario Farina,et al.  Noninvasive, Accurate Assessment of the Behavior of Representative Populations of Motor Units in Targeted Reinnervated Muscles , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[18]  R. J. Kuo,et al.  Application of ant K-means on clustering analysis , 2005 .

[19]  R. Quian Quiroga,et al.  Unsupervised Spike Detection and Sorting with Wavelets and Superparamagnetic Clustering , 2004, Neural Computation.

[20]  Roberto Merletti,et al.  The extraction of neural strategies from the surface EMG. , 2004, Journal of applied physiology.

[21]  R. Plonsey,et al.  A mathematical evaluation of the core conductor model. , 1966, Biophysical journal.

[22]  Michael A. Saunders,et al.  LSQR: An Algorithm for Sparse Linear Equations and Sparse Least Squares , 1982, TOMS.

[23]  Lucia Rita Quitadamo,et al.  Optimization of EMG-based hand gesture recognition: Supervised vs. unsupervised data preprocessing on healthy subjects and transradial amputees , 2014, Biomed. Signal Process. Control..

[24]  Pierre Comon,et al.  Handbook of Blind Source Separation: Independent Component Analysis and Applications , 2010 .

[25]  K. C. McGill,et al.  Surface electromyogram signal modelling , 2004, Medical and Biological Engineering and Computing.

[26]  V. I. Ogreba,et al.  Some improvements of equipment for inhalation methods of therapy , 1978 .

[27]  R. D'ambrosia,et al.  The Myoelectric Signal of Electrically Stimulated Muscle During Recruitment: An Inherent Feedback Pareter for a Closed-Loop Control Scheme , 1986, IEEE Transactions on Biomedical Engineering.

[28]  I. Johnstone,et al.  Ideal spatial adaptation by wavelet shrinkage , 1994 .