5-year outcome after transcatheter aortic valve implantation.

OBJECTIVES The purpose of this study was to investigate the 5-year outcome following transcatheter aortic valve implantation (TAVI). BACKGROUND Little is known about long-term outcomes following TAVI. METHODS The 5-year outcomes following successful TAVI with a balloon-expandable valve were evaluated in 88 patients. Patients who died within 30 days after TAVI were excluded. RESULTS Mean aortic valve gradient decreased from 46 ± 18 mm Hg to 10 ± 4.5 mm Hg after TAVI and 11.8 ± 5.7 mm Hg at 5 years (p for post-TAVI trend = 0.06). Mean aortic valve area increased from 0.62 ± 0.17 cm(2) to 1.67 ± 0.41 cm(2) after TAVI and 1.40 ± 0.25 cm(2) at 5 years (p for post-TAVI trend <0.01). At 5 years, 3 patients (3.4%) had moderate prosthetic valve dysfunction (moderate transvalvular regurgitation in 1, moderate stenosis in 1, and moderate mixed disease in 1). Survival rates at 1 to 5 years were 83%, 74%, 53%, 42%, and 35%, respectively. Median survival time after TAVI was 3.4 years (95% confidence interval [CI]: 2.6 to 4.3), and the risk of death was significantly increased in patients with chronic obstructive pulmonary disease (adjusted hazard ratio [HR]: 2.17; 95% CI: 1.28 to 3.70) and at least moderate paravalvular regurgitation (adjusted HR: 2.98; 95% CI: 1.44 to 6.17). CONCLUSIONS Our study demonstrated favorable long-term outcomes after TAVI. Signs of moderate prosthetic valve failure were observed in 3.4% of patients. No patients developed severe prosthetic regurgitation or stenosis. Comorbidities, notably chronic lung disease and at least moderate paravalvular regurgitation, were associated with reduced long-term survival.

[1]  S. Pocock,et al.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. , 2010, The New England journal of medicine.

[2]  G. Schuler,et al.  Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry , 2011, Heart.

[3]  J. Leipsic,et al.  Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure. , 2012, Journal of the American College of Cardiology.

[4]  E. Tay,et al.  Transcatheter Aortic Valve Implantation: Durability of Clinical and Hemodynamic Outcomes Beyond 3 Years in a Large Patient Cohort , 2010, Circulation.

[5]  M. Mack,et al.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. , 2012, The Journal of thoracic and cardiovascular surgery.

[6]  P. Mykén,et al.  A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. , 2009, The Journal of thoracic and cardiovascular surgery.

[7]  F. Maisano,et al.  Incidence and Predictors of Early and Late Mortality After Transcatheter Aortic Valve Implantation in 663 Patients With Severe Aortic Stenosis , 2011, Circulation.

[8]  M. Marchand,et al.  Carpentier-Edwards pericardial bioprosthesis in aortic or mitral position: a 12-year experience. , 1998, The Annals of thoracic surgery.

[9]  Harvey Feigenbaum,et al.  Recommendations for a standardized report for adult transthoracic echocardiography: a report from the American Society of Echocardiography's Nomenclature and Standards Committee and Task Force for a Standardized Echocardiography Report. , 2002, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[10]  Fabian Nietlispach,et al.  Transcatheter Aortic Valve Implantation: Impact on Clinical and Valve-Related Outcomes , 2009, Circulation.

[11]  Pascal Vranckx,et al.  Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium. , 2011, Journal of the American College of Cardiology.

[12]  P. Biglioli,et al.  Long-term outcomes of the Carpentier-Edwards pericardial valve prosthesis in the aortic position: effect of patient age. , 2004, The Journal of heart valve disease.

[13]  Michael J. Mack,et al.  Transcatheter versus surgical aortic-valve replacement in high-risk patients. , 2011, The New England journal of medicine.

[14]  M. Mack,et al.  ACQUIRED CARDIOVASCULAR DISEASE Transcatheter ( TAVR ) versus surgical ( AVR ) aortic valve replacement : Occurrence , hazard , risk factors , and consequences of neurologic events in the PARTNER trial , 2012 .

[15]  Susheel Kodali,et al.  Two-Year Outcomes After Transcatheter or Surgical Aortic Valve Replacement , 2013 .

[16]  D. Wood,et al.  Clinical ResearchInterventional CardiologyTranscatheter Aortic Valve Replacement: Outcomes of Patients With Moderate or Severe Mitral Regurgitation , 2012 .

[17]  R. Levine,et al.  Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. , 2003, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[18]  Susan Armstrong,et al.  Twenty-year results of the Hancock II bioprosthesis. , 2006, The Journal of heart valve disease.

[19]  Thomas Walther,et al.  Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve , 2010, Circulation.

[20]  Fabian Nietlispach,et al.  Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. , 2010, Journal of the American College of Cardiology.

[21]  P. Serruys,et al.  Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium , 2010, European heart journal.

[22]  F. Dagenais,et al.  Impact of residual regurgitation after aortic valve replacement. , 2012, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[23]  P. Serruys,et al.  Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. , 2008, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.