Application of a user-friendly comprehensive circulatory model for estimation of hemodynamic and ventricular variables

Purpose Application of a comprehensive, user-friendly, digital computer circulatory model to estimate hemodynamic and ventricular variables. Methods The closed-loop lumped parameter circulatory model represents the circulation at the level of large vessels. A variable elastance model reproduces ventricular ejection. The circulatory model has been modified embedding an algorithm able to adjust the model parameters reproducing specific circulatory conditions. The algorithm reads input variables: heart rate, aortic pressure, cardiac output, and left atrial pressure. After a preliminary estimate of circulatory parameters and ventricular elastance, it adjusts the amount of circulating blood, the value of the systemic peripheral resistance, left ventricular elastance, and ventricular rest volume. Input variables and the corresponding calculated variables are recursively compared: the procedure is stopped if the difference between input and calculated variables is within the set tolerance. At the procedure end, the model produces an estimate of ventricular volumes and Emaxl along with systemic and pulmonary pressures (output variables). The procedure has been tested using 4 sets of experimental data including left ventricular assist device assistance. Results The algorithm allows the reproduction of the circulatory conditions defined by all input variable sets, giving as well an estimate of output variables. Conclusions The algorithm permits application of the model in environments where the simplicity of use and velocity of execution are of primary importance. Due to its modular structure, the model can be modified adding new circulatory districts or changing the existing ones. The model could also be applied in educational applications.

[1]  Gianfranco Ferrari,et al.  Computer simulation of haemodynamic parameters changes with left ventricle assist device and mechanical ventilation , 2000, Comput. Biol. Medicine.

[2]  F. Clemente,et al.  Mono and Bi-ventricular Assistance: Their Effect on Ventricular Energetics , 2001, The International journal of artificial organs.

[3]  Arthur Selzer,et al.  CIRCULATORY PHYSIOLOGY: Cardiac Output and Its Regulation , 1964 .

[4]  Pascal Verdonck,et al.  Modeling Ventricular Function during Cardiac Assist: Does Time-Varying Elastance Work? , 2006, ASAIO journal.

[5]  Stewart J. Woodruff,et al.  Influence of Gravity on Cardiac Performance , 2004, Annals of Biomedical Engineering.

[6]  T Ihara,et al.  Alterations in left ventricular diastolic function in conscious dogs with pacing-induced heart failure. , 1992, The Journal of clinical investigation.

[7]  G Ferrari,et al.  A Hybrid Mock Circulatory System: Development and Testing of an Electro-hydraulic Impedance Simulator , 2003, The International journal of artificial organs.

[8]  G Ferrari,et al.  A modular numerical model of the cardiovascular system for studying and training in the field of cardiovascular physiopathology. , 1992, Journal of biomedical engineering.

[9]  T. Korakianitis,et al.  Numerical simulation of cardiovascular dynamics with different types of VAD assistance. , 2007, Journal of biomechanics.

[10]  G J Verkerke,et al.  Development of a numerical simulation model of the cardiovascular system. , 1997, Artificial organs.

[11]  R Beyar,et al.  Influence of contractile state on curvilinearity of in situ end-systolic pressure-volume relations. , 1989, Circulation.

[12]  Maciej Kozarski,et al.  A new hybrid electro-numerical model of the left ventricle , 2008, Comput. Biol. Medicine.

[13]  C De Lazzari,et al.  IABP Assistance: A Test Bench for the Analysis of its Effects on Ventricular Energetics and Hemodynamics , 2001, The International journal of artificial organs.

[14]  J. Geoffrey Chase,et al.  Experimentally verified minimal cardiovascular system model for rapid diagnostic assistance , 2005 .

[15]  S. Shroff,et al.  Evidence and quantitation of left ventricular systolic resistance. , 1985, The American journal of physiology.

[16]  R. Mark,et al.  Computational modeling of cardiovascular response to orthostatic stress. , 2002, Journal of applied physiology.

[17]  J. Dagan Pulsatile mechanical and mathematical model of the cardiovascular system , 2006, Medical and Biological Engineering and Computing.

[18]  F. Clemente,et al.  A Simple Method for Emax Trend Evaluation: In Vitro and in Vivo Results , 1999, The International journal of artificial organs.

[19]  J. V. van Herwaarden,et al.  Vertical displacement of the beating heart by the octopus tissue stabilizer: influence on coronary flow. , 1998, The Annals of thoracic surgery.

[20]  Jean Charles Gilbert,et al.  Determinants of left ventricular filling and of the diastolic pressure-volume relation. , 1989, Circulation research.

[21]  G. Rakhorst,et al.  Numerical simulation of hemodynamic changes during beating-heart surgery: analysis of the effects of cardiac position alteration in an animal model. , 2007, Artificial organs.

[22]  J D Thomas,et al.  Numeric modeling of the cardiovascular system with a left ventricular assist device. , 1999, ASAIO journal.

[23]  G Ferrari,et al.  In vitro testing of a left ventricular assist device. Study of the effect of its control strategy on energetic relationships inside the left ventricle. , 1996, Technology and health care : official journal of the European Society for Engineering and Medicine.

[24]  C De Lazzari,et al.  A Hybrid (Numerical-physical) Model of the Left Ventricle , 2001, The International journal of artificial organs.

[25]  D. Burkhoff,et al.  Assessment of Windkessel as a model of aortic input impedance. , 1988, The American journal of physiology.

[26]  et al.,et al.  A computer decision aid for medical prevention: a pilot qualitative study of the Personalized Estimate of Risks (EsPeR) system , 2003, BMC Medical Informatics Decis. Mak..

[27]  N. Westerhof,et al.  An artificial arterial system for pumping hearts. , 1971, Journal of applied physiology.

[28]  G. Ferrari,et al.  Development of a Hybrid (numerical-hydraulic) Circulatory Model: Prototype Testing and Its Response to IABP Assistance , 2005, The International journal of artificial organs.

[29]  Giuseppe Pontrelli,et al.  A Multiscale Approach for Modelling Wave Propagation in an Arterial Segment , 2004, Computer methods in biomechanics and biomedical engineering.

[30]  K B Campbell,et al.  Late-systolic pumping properties of the left ventricle. Deviation from elastance-resistance behavior. , 1990, Circulation research.

[31]  Pascal Verdonck,et al.  Pulmonary arterial compliance in dogs and pigs: the three-element windkessel model revisited. , 1999, American journal of physiology. Heart and circulatory physiology.

[32]  Tom Fahey,et al.  Evaluation of computer based clinical decision support system and risk chart for management of hypertension in primary care: randomised controlled trial , 2000, BMJ : British Medical Journal.

[33]  C. H. Chen,et al.  Single-beat estimation of end-systolic pressure-volume relation in humans. A new method with the potential for noninvasive application. , 1996, Circulation.

[34]  Peter V Coveney,et al.  Patient-specific simulation as a basis for clinical decision-making , 2008, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[35]  N Westerhof,et al.  Evaluation of methods for estimation of total arterial compliance. , 1995, The American journal of physiology.

[36]  Pascal Verdonck,et al.  Hemodynamics of a pulsatile left ventricular assist device driven by a counterpulsation pump in a mock circulation. , 2006, Artificial Organs.

[37]  佐川 喜一,et al.  Cardiac contraction and the pressure-volume relationship , 1988 .

[38]  E S Kirk,et al.  Inhibition of Coronary Blood Flow by a Vascular Waterfall Mechanism , 1975, Circulation research.