The safety of intracoronary ultrasound. A multicenter survey of 2207 examinations.

BACKGROUND Intracoronary ultrasound (ICUS) is increasingly used in clinical practice to study the natural history of coronary artery disease and to assess the effects of intracoronary, catheter-based interventions. However, the risk associated with the procedure is not well documented. METHODS AND RESULTS ICUS studies performed in 28 centers were retrospectively included; these centers agreed to contribute to the study among a total of 60 centers initially invited. Among the 2207 ICUS studies, 505 (23%) were performed in heart transplant recipients and 1702 (77%) in nontransplant patients. Indication for ICUS was diagnostic imaging in 915 (41%), drug testing in 244 (11%), and guidance for intracoronary interventions in 1048 patients (47%). There were no complications in 2034 patients (92.2%). In 87 patients (3.9%), complications occurred but were judged to be "not related" to ICUS by the operator. In 63 patients (2.9%), spasm occurred during ICUS imaging. In 9 patients (0.4%), complications other than spasm were judged to have a "certain relation" to ICUS, including acute procedural events in 6 (3 acute occlusion, 1 embolism, 1 dissection, and 1 thrombus) and major events in 3 patients (2 occlusion and 1 dissection; all resulting in myocardial infarction). In 14 patients (0.6%), complications with "uncertain relation" to ICUS were recorded, including acute procedural events in 9 (5 acute occlusion, 3 dissection, and 1 arrhythmia) and major events in 5 patients (2 myocardial infarction and 3 emergency coronary artery bypass surgery). The incidence of acute procedural or major complications judged to be associated with ICUS (uncertain relation or certain relation to ICUS) was compared in different patient groups. The complication rate was higher in patients with unstable angina or acute myocardial infarction (2.1% events) as compared with patients with stable angina pectoris and asymptomatic patients (0.8% and 0.4%, respectively; chi 2 = 10.9, P < .01). These complications were also more frequent in patients undergoing interventions (1.9%) as compared with transplant and nontransplant patients undergoing diagnostic ICUS imaging (0% and 0.6%, respectively; chi 2 = 13.5, P < .001). Adverse events were few, and no association was detected between these events and the size or type of ICUS catheter used. CONCLUSIONS ICUS is associated with (but not necessarily the direct cause of) a minor acute clinical risk. Vessel spasm is the most frequent event occurring during ICUS. Other complications predominantly occur in patients with acute coronary syndromes and during guidance for intervention.

[1]  E. Topol,et al.  Relation of Stenosis Morphology and Clinical Presentation to the Procedural Results of Directional Coronary Atherectomy , 1991, Circulation.

[2]  P C Douek,et al.  Arterial responses to balloon coronary angioplasty: an intravascular ultrasound study. , 1992, Journal of the American College of Cardiology.

[3]  M. Krucoff,et al.  Intracoronary ultrasound evaluation of interventional technologies. , 1991, The American journal of cardiology.

[4]  K. Mizuno,et al.  Angioscopic evaluation of coronary-artery thrombi in acute coronary syndromes. , 1992, The New England journal of medicine.

[5]  M. Leon,et al.  Target lesion calcification in coronary artery disease: an intravascular ultrasound study. , 1992, Journal of the American College of Cardiology.

[6]  C. Buller,et al.  Mechanisms of balloon angioplasty and directional coronary atherectomy as assessed by intracoronary ultrasound. , 1992, Journal of the American College of Cardiology.

[7]  A. Íñiguez,et al.  Angiographic changes induced by intracoronary ultrasound imaging before and after coronary angioplasty. , 1993, American heart journal.

[8]  E. Tuzcu,et al.  Determinants of primary success in elective percutaneous transluminal coronary angioplasty for significant narrowing of a single major coronary artery. , 1988, The American journal of cardiology.

[9]  A. Yeung,et al.  Functional significance of intimal thickening as detected by intravascular ultrasound early and late after cardiac transplantation. , 1993, Circulation.

[10]  Paul G. Yock,et al.  Intravascular ultrasound: development and clinical potential , 1988 .

[11]  D. Faxon,et al.  Percutaneous transluminal coronary angioplasty in 1985-1986 and 1977-1981. The National Heart, Lung, and Blood Institute Registry. , 1988, The New England journal of medicine.

[12]  J. Douglas,et al.  In-hospital morbidity and mortality in patients undergoing elective coronary angioplasty. , 1985, Circulation.

[13]  D. Cumberland,et al.  Intravascular ultrasound imaging combined with coronary angioplasty , 1992, The Lancet.

[14]  J. Hermiller,et al.  In vivo validation of compensatory enlargement of atherosclerotic coronary arteries. , 1993, The American journal of cardiology.

[15]  R Erbel,et al.  Classification of morphologic effects of percutaneous transluminal coronary angioplasty assessed by intravascular ultrasound. , 1992, American Journal of Cardiology.

[16]  F J Pinto,et al.  Intracoronary Ultrasound in Cardiac Transplant Recipients: In Vivo Evidence of “Angiographically Silent” Intimal Thickening , 1991, Circulation.

[17]  J. Tobis,et al.  Morphological Effects of Coronary Balloon Angioplasty In Vivo Assessed by Intravascular Ultrasound Imaging , 1992, Circulation.

[18]  S. Ellis,et al.  Angiographic and clinical predictors of acute closure after native vessel coronary angioplasty. , 1988, Circulation.

[19]  J. Hodgson,et al.  Intracoronary ultrasound imaging: correlation of plaque morphology with angiography, clinical syndrome and procedural results in patients undergoing coronary angioplasty. , 1993, Journal of the American College of Cardiology.

[20]  Steven E. Nissen,et al.  Intravascular Ultrasound Assessment of Lumen Size and Wall Morphology in Normal Subjects and Patients With Coronary Artery Disease , 1991, Circulation.

[21]  S. Kelsey,et al.  Acute coronary events associated with percutaneous transluminal coronary angioplasty. , 1984, The American journal of cardiology.

[22]  R. Popp,et al.  Immediate and one-year safety of intracoronary ultrasonic imaging. Evaluation with serial quantitative angiography. , 1993, Circulation.

[23]  R D Safian,et al.  Coronary atherectomy. Clinical, angiographic, and histological findings and observations regarding potential mechanisms. , 1990, Circulation.

[24]  P. Fitzgerald,et al.  Contribution of Localized Calcium Deposits to Dissection After Angioplasty: An Observational Study Using Intravascular Ultrasound , 1992, Circulation.

[25]  A. Buchwald,et al.  Intravascular ultrasound imaging of human coronary arteries after percutaneous transluminal angioplasty: morphologic and quantitative assessment. , 1991, American heart journal.

[26]  R. Wilson,et al.  Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man. , 1985, Circulation.

[27]  Walter L. Henry,et al.  Intravascular Ultrasound Imaging of Human Coronary Arteries In Vivo: Analysis of Tissue Characterizations With Comparison to In Vitro Histological Specimens , 1991, Circulation.