Normal Adult Values, Diurnal Variation, and Repeatability of Nasal Nitric Oxide Measurement

Reports of elevated nasal nitric oxide (NO) levels in allergic rhinitis suggest that nasal NO levels could be a valuable marker of upper airway inflammation, provided that the reproducibility of nasal NO measurement is acceptable. The aims of this study were to evaluate the precision with which nasal NO levels can be measured at single point in time, and to quantify within-day and between-day variation. Nasal NO was measured using a modified chemiluminiscence analyzer. Population data were normally distributed, as judged by testing for skewness and kurtosis. NO levels were not related to age or gender, and there was no evidence of diurnal variation. Sampling rates of 250 mL/minute and 500 mL/minute at a single point in time had acceptable reproducibility (coefficients of variation 10.2% and 6.6%, respectively). However, within-day variation (coefficient of variation 13.4%) and between-day variation (coefficient of variation 11.8%), at a sampling rate of 500 L/minute, were substantially higher. These findings highlight the importance of taking measurement variation into account, in the interpretation of NO levels, in clinical research and, potentially, in routine practice. In individual patients, an alteration of 20–25% in NO levels is required, to ensure that change is genuine and not ascribable to the noise of measurement.

[1]  P. Barnes,et al.  Exhaled and nasal nitric oxide measurements: recommendations. The European Respiratory Society Task Force. , 1997, The European respiratory journal.

[2]  A. Didier,et al.  Nasal nitric oxide is increased in allergic rhinitis , 1997, Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology.

[3]  R. Eccles,et al.  Changes in nasal nitric oxide concentration associated with symptoms of common cold and treatment with a topical nasal decongestant. , 1997, Acta oto-laryngologica.

[4]  S. Lindberg,et al.  Nitric oxide (NO) production in the upper airways is decreased in chronic sinusitis. , 1997, Acta oto-laryngologica.

[5]  S. Durham,et al.  Nasal nitric oxide is increased in patients with asthma and allergic rhinitis and may be modulated by nasal glucocorticoids. , 1997, The Journal of allergy and clinical immunology.

[6]  E. Weitzberg,et al.  Exhaled nitric oxide in paediatric asthma and cystic fibrosis. , 1996, Archives of disease in childhood.

[7]  R. Dinwiddie,et al.  Reduced upper airway nitric oxide in cystic fibrosis. , 1996, Archives of disease in childhood.

[8]  P. Howarth,et al.  Increased levels of exhaled nitric oxide during nasal and oral breathing in subjects with seasonal rhinitis. , 1996, The Journal of allergy and clinical immunology.

[9]  T. Hökfelt,et al.  High nitric oxide production in human paranasal sinuses , 1995, Nature Medicine.

[10]  S. Chinn Statistics in respiratory medicine. 2. Repeatability and method comparison. , 1991, Thorax.

[11]  S. Chinn,et al.  The assessment of methods of measurement. , 1990, Statistics in medicine.