Effects of types of ventilation system on indoor particle concentrations in residential buildings.

UNLABELLED The objective of this study was to quantify the influence of ventilation systems on indoor particle concentrations in residential buildings. Fifteen occupied, single-family apartments were selected from three sites. The three sites have three different ventilation systems: unbalanced mechanical ventilation, balanced mechanical ventilation, and natural ventilation. Field measurements were conducted between April and June 2012, when outdoor air temperatures were comfortable. Number concentrations of particles, PM2.5 and CO2 , were continuously measured both outdoors and indoors. In the apartments with natural ventilation, I/O ratios of particle number concentrations ranged from 0.56 to 0.72 for submicron particles, and from 0.25 to 0.60 for particles larger than 1.0 μm. The daily average indoor particle concentration decreased to 50% below the outdoor level for submicron particles and 25% below the outdoor level for fine particles, when the apartments were mechanically ventilated. The two mechanical ventilation systems reduced the I/O ratios by 26% for submicron particles and 65% for fine particles compared with the natural ventilation. These results showed that mechanical ventilation can reduce exposure to outdoor particles in residential buildings. PRACTICAL IMPLICATIONS Results of this study confirm that mechanical ventilation with filtration can significantly reduce indoor particle levels compared with natural ventilation. The I/O ratios of particles substantially varied at the naturally ventilated apartments because of the influence of variable window opening conditions and unsteadiness of wind flow on the penetration of outdoor air particles. For better prediction of the exposure to outdoor particles in naturally ventilated residential buildings, it is important to understand the penetration of outdoor particles with variable window opening conditions.

[1]  Olli Seppänen,et al.  Indoor Climate and the Performance of Ventilation in Finnish Residences , 1992 .

[2]  R. Dear,et al.  Thermal adaptation in the built environment: a literature review , 1998 .

[3]  Leif Øie,et al.  The Ventilation Rate of 344 Oslo Residences , 1998 .

[4]  L Morawska,et al.  Effect of ventilation and filtration on submicrometer particles in an indoor environment. , 2000, Indoor air.

[5]  T. Haahtela,et al.  Penetration of nitrogen oxides and particles from outdoor into indoor air and removal of the pollutants through filtration of incoming air. , 2000, Indoor air.

[6]  De-Ling Liu,et al.  Modeling pollutant penetration across building envelopes , 2001 .

[7]  W. Fisk,et al.  Performance and costs of particle air filtration technologies. , 2002, Indoor air.

[8]  L. Wallace,et al.  Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windows* , 2002, Journal of Exposure Analysis and Environmental Epidemiology.

[9]  Phillip L. Williams,et al.  A comparison of two direct-reading aerosol monitors with the federal reference method for PM2.5 in indoor air , 2002 .

[10]  W. Ott,et al.  The Effect of Opening Windows on Air Change Rates in Two Homes , 2002, Journal of the Air & Waste Management Association.

[11]  Q Chen,et al.  Air flow and particle control with different ventilation systems in a classroom. , 2003, Indoor air.

[12]  B. Wehner,et al.  How do the indoor size distributions of airborne submicron and ultrafine particles in the absence of significant indoor sources depend on outdoor distributions? , 2003, Indoor air.

[13]  T Schneider,et al.  'EUROPART'. Airborne particles in the indoor environment. A European interdisciplinary review of scientific evidence on associations between exposure to particles in buildings and health effects. , 2003, Indoor air.

[14]  W. Nazaroff Indoor particle dynamics. , 2004, Indoor air.

[15]  J Richmond-Bryant,et al.  Transport of airborne particles within a room. , 2006, Indoor air.

[16]  J. L. Parker,et al.  Particle size distribution and composition in a mechanically ventilated school building during air pollution episodes. , 2008, Indoor air.

[17]  N. Tippayawong,et al.  Indoor/outdoor relationships of size-resolved particle concentrations in naturally ventilated school environments , 2009 .

[18]  P. Linden,et al.  Particle transport in low-energy ventilation systems. Part 1: theory of steady states. , 2009, Indoor air.

[19]  Andrew K. Persily,et al.  Infiltration of outdoor ultrafine particles into a test house. , 2010, Environmental science & technology.

[20]  P Heiselberg,et al.  Short-term airing by natural ventilation - implication on IAQ and thermal comfort. , 2010, Indoor air.

[21]  Bin Zhao,et al.  Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor , 2011 .

[22]  J. S. Park,et al.  A field study of occupant behavior and energy consumption in apartments with mechanical ventilation , 2012 .

[23]  Y Zhu,et al.  Characterizing ultrafine particles and other air pollutants at five schools in South Texas. , 2012, Indoor air.

[24]  J. A. Siegel,et al.  Penetration of ambient submicron particles into single-family residences and associations with building characteristics. , 2012, Indoor air.

[25]  Junseok Park,et al.  Long-term field measurement on effects of wind speed and directional fluctuation on wind-driven cross ventilation in a mock-up building , 2013 .