Tracheal intubation in patients with cervical spine immobilization: A comparison of McGrath® video laryngoscope and Truview EVO2® laryngoscope

Background and Aims: Literature suggests that glottic view is better when using McGrath® Video laryngoscope and Truview® in comparison with McIntosh blade. The purpose of this study was to evaluate the effectiveness of McGrath Video laryngoscope in comparison with Truview laryngoscope for tracheal intubation in patients with simulated cervical spine injury using manual in-line stabilisation. Methods: This prospective randomised study was undertaken in operation theatre of a tertiary referral centre after approval from the Institutional Review Board. A total of 100 consenting patients presenting for elective surgery requiring tracheal intubation were randomly assigned to undergo intubation using McGrath® Video laryngoscope (n = 50) or Truview® (n = 50) laryngoscope. In all patients, we applied manual-in-line stabilisation of the cervical spine throughout the airway management. Statistical testing was conducted with the statistical package for the social science system version SPSS 17.0. Demographic data, airway assessment and haemodynamics were compared using the Chi-square test. A P < 0.05 was considered significant. Results: The time to successful intubation was less with McGrath video laryngoscope when compared to Truview (30.02 s vs. 38.72 s). However, there was no significant difference between laryngoscopic views obtained in both groups. The number of second intubation attempts required and incidence of complications were negligible with both devices. Success rate of intubation with both devices was 100%. Intubation with McGrath Video laryngoscope caused lesser alterations in haemodynamics. Conclusions: Both laryngoscopes are reliable in case of simulated cervical spine injury using manual-in-line stabilisation with 100% success rate and good glottic view.

[1]  P. Bassett,et al.  Randomized controlled trial of the A.P. Advance, McGrath, and Macintosh laryngoscopes in normal and difficult intubation scenarios: a manikin study. , 2011, British journal of anaesthesia.

[2]  C. Werner,et al.  Comparison of the McGrath® Series 5 and GlideScope® Ranger with the Macintosh laryngoscope by paramedics , 2011, Scandinavian journal of trauma, resuscitation and emergency medicine.

[3]  J. Laffey,et al.  Comparison of the Airtraq® and Truview® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins , 2009, BMC emergency medicine.

[4]  J. Laffey,et al.  Comparison of the Glidescope, the Pentax AWS, and the Truview EVO2 with the Macintosh laryngoscope in experienced anaesthetists: a manikin study. , 2009, British journal of anaesthesia.

[5]  G. Savoldelli,et al.  Comparison of the Glidescope®, the McGrath®, the Airtraq® and the Macintosh laryngoscopes in simulated difficult airways * , 2008, Anaesthesia.

[6]  J. Laffey,et al.  Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization. , 2008, British journal of anaesthesia.

[7]  D. Ray,et al.  Use of the McGrath videolaryngoscope in the management of difficult and failed tracheal intubation. , 2008, British journal of anaesthesia.

[8]  J. Laffey,et al.  A comparison of direct and indirect laryngoscopes and the ILMA in novice users: a manikin study , 2007, Anaesthesia.

[9]  M. Barak,et al.  A comparison of the Truview® blade with the Macintosh blade in adult patients , 2007, Anaesthesia.

[10]  M. Stacey,et al.  Ease of placement of the laryngeal mask during manual in-line neck stabilization. , 1998, British journal of anaesthesia.

[11]  K. Heath The effect on laryngoscopy of different cervical spine immobilization techniques , 1994, Anaesthesia.

[12]  P. Charters,et al.  Defining a standard intubating position using "angle finder". , 1989, British journal of anaesthesia.

[13]  R. Stoelting Circulatory changes during direct laryngoscopy and tracheal intubation: influence of duration of laryngoscopy with or without prior lidocaine. , 1977, Anesthesiology.

[14]  A. Forbes,et al.  Acute hypertension during induction of anaesthesia and endotracheal intubation in normotensive man. , 1970, British journal of anaesthesia.