Capsule endoscopy with flexible spectral imaging color enhancement reduces the bile pigment effect and improves the detectability of small bowel lesions

BackgroundCapsule endoscopy with flexible spectral imaging color enhancement (CE-FICE) has been reported to improve the visualization and detection of small-bowel lesions, however, its clinical usefulness is still not established. Therefore, we conducted a study to evaluate whether CE-FICE contributes to improve the detectability of small-bowel lesions by CE trainees.MethodsFour gastroenterology trainees without prior CE experience were asked to read and interpret 12 CE videos. Each of the videos was read by conventional visualization method and under three different FICE settings. To evaluate whether the lesion recognition ability of the CE trainees could be improved by the FICE technology, the lesion detection rate under each of the three FICE settings was compared with that by conventional CE. CE trainees tend to miss small-bowel lesions in bile-pigment-positive condition, therefore we evaluated whether CE-FICE contributes to reducing the bile-pigment effect. The bile-pigment condition was determined by the color values around the small-bowel lesions according to the results of the receiver-operating-characteristic analysis. Moreover, we also evaluated whether poor bowel preparion might affect the accuracy of lesion recognition by CE-FICE.ResultsOf a total of 60 angioectasias, CE trainees identified 26 by conventional CE, 40 under FICE setting 1, 38 under FICE setting 2, and 31 under FICE setting 3. Of a total of 82 erosions/ulcerations, CE trainees identified 38 by conventional CE, 62 under FICE setting 1, 60 under FICE setting 2, and 20 under FICE setting 3. Compared with conventional CE, FICE settings 1 and 2 significantly improved the detectability of angioectasia (P = 0.0017 and P = 0.014, respectively) and erosions/ulcerations (P = 0.0012 and P = 0.0094, respectively). Although the detectability of small-bowel lesions by conventional CE (P = 0.020) and under FICE setting 2 (P = 0.0023) was reduced by the presence of bile-pigments, that under FICE setting 1 was not affected (P = 0.59). Our results also revealed that in poor bowel visibility conditions, CE-FICE yielded a high rate of false-positive findings.ConclusionsCE-FICE may reduce the bile-pigment effect and improve the detectability of small-bowel lesions by CE trainees; the reliability of CE-FICE may be improved by good bowel preparation.

[1]  A. Nakajima,et al.  Ingesting 500 ml of Polyethylene Glycol Solution During Capsule Endoscopy Improves the Image Quality and Completion Rate to the Cecum , 2008, Digestive Diseases and Sciences.

[2]  M. Singer,et al.  Prospective evaluation of small bowel preparation with bisacodyl and sodium phosphate for capsule endoscopy. , 2008, World journal of gastroenterology.

[3]  J. Santisi,et al.  The accuracy of an endoscopy nurse in interpreting capsule endoscopy , 2003, American Journal of Gastroenterology.

[4]  Thomas Rabenstein,et al.  Computed Virtual Chromoendoscopy for Classification of Small Colorectal Lesions: A Prospective Comparative Study , 2008, The American Journal of Gastroenterology.

[5]  P. Swain,et al.  Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding , 2003, Gut.

[6]  J Pohl,et al.  Computed virtual chromoendoscopy: a new tool for enhancing tissue surface structures , 2007, Endoscopy.

[7]  Paul Swain,et al.  Capsule endoscopy in the evaluation of patients with suspected small intestinal bleeding: Results of a pilot study. , 2002, Gastrointestinal endoscopy.

[8]  J. Malagelada,et al.  Capsule Endoscopy Versus Computed Tomographic or Standard Angiography for the Diagnosis of Obscure Gastrointestinal Bleeding , 2007, The American Journal of Gastroenterology.

[9]  G. Costamagna,et al.  A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease. , 2002, Gastroenterology.

[10]  T. Ponchon,et al.  Diagnostic value of endoscopic capsule in patients with obscure digestive bleeding: blinded comparison with video push-enteroscopy. , 2003, Endoscopy.

[11]  C. Ell,et al.  Computed image modification for enhancement of small-bowel surface structures at video capsule endoscopy , 2010, Endoscopy.

[12]  E. Rondonotti,et al.  Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases. , 2004, Gastroenterology.

[13]  E. Kuipers,et al.  Double-Balloon Enteroscopy: Indications, Diagnostic Yield, and Complications in a Series of 275 Patients with Suspected Small-Bowel Disease , 2006, Endoscopy.

[14]  Detection of abnormal lesions recorded by capsule endoscopy. A prospective study comparing endoscopist's and nurse's accuracy. , 2006, Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver.

[15]  G. Meron The development of the swallowable video capsule (M2A). , 2000, Gastrointestinal endoscopy.

[16]  Paul Bassett,et al.  Computer-aided learning in capsule endoscopy leads to improvement in lesion recognition ability. , 2009, Gastrointestinal endoscopy.

[17]  A. Panani,et al.  Bowel preparation increases the diagnostic yield of capsule endoscopy: a prospective, randomized, controlled study. , 2004, Gastrointestinal endoscopy.

[18]  K. Chayama,et al.  Improved detectability of small-bowel lesions via capsule endoscopy with computed virtual chromoendoscopy: A pilot study , 2011, Scandinavian journal of gastroenterology.

[19]  N. Kalantzis,et al.  The role of wireless capsule endoscopy in investigating unexplained iron deficiency anemia after negative endoscopic evaluation of the upper and lower gastrointestinal tract. , 2006, Endoscopy.

[20]  Shinji Tanaka,et al.  Evaluation and validation of computed virtual chromoendoscopy in early gastric cancer. , 2009, Gastrointestinal endoscopy.

[21]  C. Daskalakis,et al.  A validation study of 3 grading systems to evaluate small-bowel cleansing for wireless capsule endoscopy: a quantitative index, a qualitative evaluation, and an overall adequacy assessment. , 2009, Gastrointestinal endoscopy.

[22]  C. Mulder,et al.  Description of a novel grading system to assess the quality of bowel preparation in video capsule endoscopy , 2011, Endoscopy.

[23]  Shinji Tanaka,et al.  Improved visibility of lesions of the small intestine via capsule endoscopy with computed virtual chromoendoscopy. , 2011, Gastrointestinal endoscopy.

[24]  Hirokazu Takahashi,et al.  Incidence of Small Bowel Injury Induced by Low-Dose Aspirin: A Crossover Study Using Capsule Endoscopy in Healthy Volunteers , 2009, Digestion.

[25]  O. Pech,et al.  Comparison of computed virtual chromoendoscopy and conventional chromoendoscopy with acetic acid for detection of neoplasia in Barrett’s esophagus , 2007, Endoscopy.

[26]  R. Sidhu,et al.  Is formal training necessary for capsule endoscopy? The largest gastroenterology trainee study with controls. , 2008, Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver.

[27]  Hirokazu Takahashi,et al.  Characteristics of small bowel injury in symptomatic chronic low-dose aspirin users: the experience of two medical centers in capsule endoscopy , 2009, Journal of Gastroenterology.

[28]  S. Ramirez,et al.  Is a 2-Liter PEG Preparation Useful Before Capsule Endoscopy? , 2005, Journal of clinical gastroenterology.

[29]  R. McNeill Alexander Winging their way , 2000, Nature.

[30]  T. Ponchon,et al.  Long-term follow-up of patients with endoscopic treatment of sporadic adenomas of the papilla of vater. , 2003, Endoscopy.

[31]  K. Sugano,et al.  Diagnosis and treatment of obscure GI bleeding at double balloon endoscopy. , 2007, Gastrointestinal endoscopy.

[32]  P. Swain,et al.  Wireless capsule endoscopy. , 2002, The Israel Medical Association journal : IMAJ.