Grid Synchronization of Wind Turbine Converters under Transient Grid Faults using a Double Synchronous Reference Frame PLL

This work employs the double synchronous reference frame PLL (DSRF-PLL) as an effective method for grid synchronization of WT's power converters in the presence of transient faults in the grid. The DSRF-PLL exploits a dual synchronous reference frame voltage characterization, adding a decoupling network to a standard SRF-PLL in order to effectively separate the positive- and negative-sequence voltage components in a fast and accurate way. Experimental evaluation of the proposed grid synchronization method and simulations regarding its application to ride through transient faults verify and validate the excellent behavior of the DSRF-PLL in the grid synchronization of WT's power converters under unfavorable grid conditions.

[1]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[2]  V. Blasko,et al.  Operation of a phase locked loop system under distorted utility conditions , 1997 .

[3]  Stefan Lundberg,et al.  A DFIG wind turbine ride‐through system. Influence on the energy production , 2004 .

[4]  Arindam Ghosh,et al.  A New Algorithm for the Generation of Reference Voltages of a DVR Using the Method of Instantaneous Symmetrical Components , 2001 .

[5]  Tao Sun Power Quality of Grid-Connected Wind Turbines with DFIG and Their Interaction with the Grid , 2004 .

[6]  M.R. Iravani,et al.  A method for synchronization of power electronic converters in polluted and variable-frequency environments , 2004, IEEE Transactions on Power Systems.

[7]  Math Bollen,et al.  Voltage dips at the terminals of wind power installations , 2005 .

[8]  Thomas Ackermann,et al.  International comparison of requirements for connection of wind turbines to power systems , 2005 .

[9]  M. Liserre,et al.  Independent PQ Control for Distributed Power Generation Systems under Grid Faults , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[10]  K. Nam,et al.  An instantaneous phase angle detection algorithm under unbalanced line voltage condition , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[11]  Math Bollen,et al.  Characteristic of voltage dips (sags) in power systems , 2000 .

[12]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .

[13]  J. Svensson Synchronisation methods for grid-connected voltage source converters , 2001 .

[14]  D. Boroyevich,et al.  Double Synchronous Reference Frame PLL for Power Converters Control , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[15]  M. Liserre,et al.  Control Strategies for Distributed Power Generation Systems Operating on Faulty Grid , 2006, 2006 IEEE International Symposium on Industrial Electronics.