Development of a Capacitive Sensor for Concrete Structure Health Monitoring

Abstract A novel low-cost capacitive transducer (CT) using capacitance signals, which has the potential to provide accurate health assessment and damage prediction for reinforcement concrete structures, is developed in this study. Two designs of capacitive transducers are discussed for condition assessment of rebar and concrete, respectively. Both of them consist of a supporting structure and a pair of corresponding parallel electrode plates. In order to verify the effectiveness of the designed capacitive sensor, a series of preliminary experiments are conducted. The results show that the detected CT signals rise with the increasing rebar size. Pure cement paste and fiber-reinforced concrete have demonstrated a stable dielectric constant under the same fabrication conditions. To simulate the real reinforced concrete case, various sizes of rebars were placed in fiber reinforced concrete. It is found that monitoring the CT signals is an effective way to assess the rebar diameters inside concrete. Experiments results also showed that CT signals could be applied to predict rebar positions inside the concrete. Finally, FEM simulations were implemented for the last experiment, and comparison results have well verified the effectiveness of the developed capacitive sensor. The whole work has demonstrated a promising application of the capacitive sensor in NDT of reinforced concrete in the future.

[1]  Xiaosheng Wei,et al.  Determination of Concrete Setting Time Using Electrical Resistivity Measurement , 2007 .

[2]  J. Prabakar,et al.  Prediction of rebar profile in a earth retaining RCC structure using cover meter survey , 2007 .

[3]  H. S. Lien,et al.  Measurement radius of reinforcing steel bar in concrete using digital image GPR , 2009 .

[4]  Hoon Sohn Noncontact laser sensing technology for structural health monitoring and nondestructive testing (presentation video) , 2014, Smart Structures.

[5]  Ruzairi Abdul Rahim,et al.  Sensor modeling for portable electrical capacitance tomography system using simulation by COMSOL multiphysics , 2012 .

[6]  V. Utsi,et al.  Measurement of reinforcement bar depths and diameters in concrete , 2004, Proceedings of the Tenth International Conference on Grounds Penetrating Radar, 2004. GPR 2004..

[7]  A. Robert Dielectric permittivity of concrete between 50 Mhz and 1 Ghz and GPR measurements for building materials evaluation , 1998 .

[8]  J. H. Bungey,et al.  SUB-SURFACE RADAR TESTING OF CONCRETE: A REVIEW , 2004 .

[9]  Zongjin Li,et al.  Hydration monitoring of cement-based materials with resistivity and ultrasonic methods , 2009 .

[10]  Youyuan Lu,et al.  Damage monitoring of reinforced concrete frames under seismic loading using cement-based piezoelectric sensor , 2011 .

[11]  Steve Millard,et al.  Practical measurement of concrete resistivity , 1991 .

[12]  Dominik Sankowski,et al.  Application of twin-plane ECT sensor for identification of the internal imperfections inside concrete beams , 2016, 2016 IEEE International Instrumentation and Measurement Technology Conference Proceedings.

[13]  G. Klysz,et al.  Determination of volumetric water content of concrete using ground-penetrating radar , 2007 .

[14]  Zongjin Li,et al.  Monitoring of cement hydration using embedded piezoelectric transducers , 2008 .

[15]  David A. Hutchins,et al.  Non-destructive evaluation of concrete using a capacitive imaging technique : preliminary modelling and experiments , 2010 .

[16]  Siti Fatimah Abdul Rahman,et al.  Embedded capacitor sensor for monitoring corrosion of reinforcement in concrete , 2012 .

[17]  Herbert Wiggenhauser,et al.  A Study of Concrete Hydration and Dielectric Relaxation Mechanism Using Ground Penetrating Radar and Short-Time Fourier Transform , 2010, EURASIP J. Adv. Signal Process..

[18]  Fan Jiansheng,et al.  Introduction of the revised contents of composite steel concretebeams in China Design Code of Steel Structures (GB50017-2002) , 2003 .

[19]  Surendra P. Shah,et al.  Early Detection of Steel Rebar Corrosion by Acoustic Emission Monitoring , 1995 .

[20]  J. Rhazi,et al.  Non-destructive evaluation of concrete moisture by GPR: Experimental study and direct modeling , 2005 .

[21]  Guangyin Lu,et al.  Review of GPR Rebar Detection , 2009 .

[22]  Hongyan Ma,et al.  Ultrasonic monitoring of the early-age hydration of mineral admixtures incorporated concrete using cement-based piezoelectric composite sensors , 2015 .

[23]  Michael Raupach,et al.  Half-cell potential measurements—Potential mapping on reinforced concrete structures , 2003 .

[24]  G. Klysz,et al.  Use of capacitive and GPR techniques for the non-destructive evaluation of cover concrete , 2008 .

[25]  Xiaosheng Wei,et al.  Early Hydration Process of Portland Cement Paste by Electrical Measurement , 2006 .

[26]  Sung Quek,et al.  EXTRACTING DIMENSIONAL INFORMATION FROM STEEL REINFORCING BARS IN CONCRETE USING NEURAL NETWORKS TRAINED ON DATA FROM AN INDUCTIVE SENSOR , 2004 .

[27]  Zongjin Li,et al.  Electrical method to evaluate elastic modulus of early age concrete , 2015 .

[28]  Zongjin Li,et al.  Application of GEM Equation in Microstructure Characterization of Cement-Based Materials , 2009 .

[29]  Jr B. F. Spencer,et al.  Structural Health Monitoring Using Smart Sensors , 2007 .