Developing Inspection Methodology of Solar Energy Plants by Thermal Infrared Sensor on Board Unmanned Aerial Vehicles

Photovoltaic (PV) power generation facilities have been built on various scales due to rapid growth in response to demand for renewable energy. Facilities built on diverse terrain and on such a scale are required to employ fast and accurate monitoring technology for stable electrical production and maintenance. The purpose of this study was to develop a technology to analyze the normal operation and failure of solar modules by acquiring images by attaching optical and thermal infrared sensors to unmanned aerial vehicles (UAVs) and producing orthographic images of temperature information. The results obtained in this study are as follows: (1) a method of using optical and thermal infrared sensors with different resolutions at the same time is able to produce accurate spatial information, (2) it is possible to produce orthographic images of thermal infrared images, (3) the analysis of the temperature fluctuation characteristics of the solar panel and cell showed that the abnormal module and cell displayed a larger temperature change than the normal module and cell, and (4) the abnormal heat generation of the panel and cell can be accurately discerned by the abnormal state panel and cell through the spatial distribution of the temperature. It is concluded that the inspection method of the solar module using the obtained UAV-based thermal infrared sensor can be useful for safety inspection and monitoring of the rapidly growing solar power generation facility.

[1]  Ronald G. Driggers,et al.  Surveillance and Reconnaissance Imaging Systems: Modeling and Performance Prediction , 2001 .

[2]  Amrita Das,et al.  A new approach to estimate the spatial distribution of solar radiation using topographic factor and sunshine duration in South Korea , 2015 .

[3]  Jin-Ki Park,et al.  Application trend of unmanned aerial vehicle (UAV) image in agricultural sector: Review and proposal , 2015 .

[4]  Guido Morgenthal,et al.  Quality Assessment of Unmanned Aerial Vehicle (UAV) Based Visual Inspection of Structures , 2014 .

[5]  W. Herrmann,et al.  Hot spot tests for crystalline silicon modules , 2005, Conference Record of the Thirty-first IEEE Photovoltaic Specialists Conference, 2005..

[6]  Lili Shen,et al.  A Self-Organizing Spatial Clustering Approach to Support Large-Scale Network RTK Systems , 2018, Sensors.

[7]  M. V. Guisado,et al.  Solar resources and power potential mapping in Vietnam using satellite-derived and GIS-based information , 2015 .

[8]  Mohammadreza Aghaei,et al.  Light Unmanned Aerial Vehicles (UAVs) for Cooperative Inspection of PV Plants , 2014, IEEE Journal of Photovoltaics.

[9]  K. Emery,et al.  Hot spot susceptibility and testing of PV modules , 1991, The Conference Record of the Twenty-Second IEEE Photovoltaic Specialists Conference - 1991.

[10]  C. Buerhop-Lutz,et al.  Quality Control of PV-Modules in the Field Using a Remote-Controlled Drone with an Infrared Camera , 2012 .

[11]  C. Buerhop-Lutz,et al.  Field Inspection of PV-Modules Using Aerial, Drone-Mounted Thermography , 2014 .

[12]  Imane Sebari,et al.  Thermal Infrared and Visual Inspection of Photovoltaic Installations by UAV Photogrammetry—Application Case: Morocco , 2018, Drones.

[13]  Mohammadreza Aghaei,et al.  Planning for PV plant performance monitoring by means of unmanned aerial systems (UAS) , 2015 .

[14]  W. Herrmann,et al.  Hot spot investigations on PV modules-new concepts for a test standard and consequences for module design with respect to bypass diodes , 1997, Conference Record of the Twenty Sixth IEEE Photovoltaic Specialists Conference - 1997.

[15]  Oscar Duque-Perez,et al.  Technological review of the instrumentation used in aerial thermographic inspection of photovoltaic plants , 2018, Renewable and Sustainable Energy Reviews.

[16]  Eduardo Lorenzo,et al.  Observed degradation in photovoltaic plants affected by hot‐spots , 2014 .

[17]  Philip Jennings,et al.  Detectable faults on recently installed solar modules in Western Australia , 2014 .

[18]  Amrita Das,et al.  Integrated model for predicting rice yield with climate change , 2018 .

[19]  T. J. McMahon,et al.  History of accelerated and qualification testing of terrestrial photovoltaic modules: A literature review , 2009 .

[20]  Siva Ramakrishna Madeti,et al.  Monitoring system for photovoltaic plants: A review , 2017 .

[21]  A. Gastli,et al.  Solar electricity prospects in Oman using GIS-based solar radiation maps , 2010 .

[22]  Mohammadreza Aghaei,et al.  Innovative Automated Control System for PV Fields Inspection and Remote Control , 2015, IEEE Transactions on Industrial Electronics.

[23]  S. Leva,et al.  Image resolution and defects detection in PV inspection by unmanned technologies , 2016, 2016 IEEE Power and Energy Society General Meeting (PESGM).

[24]  Jong Hwa Park,et al.  Crops Classification Using Imagery of Unmanned Aerial Vehicle (UAV) , 2015 .

[25]  Christoph J. Brabec,et al.  Reliability of IR-imaging of PV-plants under operating conditions , 2012 .