Detailed ray‐tracing code for capillary optics

A description of a detailed ray-tracing code for capillary optics is given and a number of examples of the use of the program are discussed. The model uses numerically defined capillary shapes and is able to simulate the behaviour of devices having shape distortions of various nature, including bending of the capillary. Comparisons are made with previously published capillary calculation models and with experimental results described in the literature. The use of the code is also demonstrated for the optimization of conical capillary dimensions assuming extended x-ray sources. With respect to the modelling of realistic capillary shapes, the beam transmission properties of an ellipsoidal device are calculated, using the experimentally determined capillary profile.

[1]  L. Vincze,et al.  Microscopic X-ray fluorescence analysis. Invited lecture , 1994 .

[2]  T. J. Tanaka,et al.  Low-energy x-ray interaction coefficients: Photoabsorption, scattering, and reflection: E = 100–2000 eV Z = 1–94☆ , 1982 .

[3]  Per Engström,et al.  A submicron synchrotron x-ray beam generated by capillary optics , 1991 .

[4]  A. Rindby,et al.  Progress in X-ray microbeam spectroscopy , 1993 .

[5]  Emil Wolf,et al.  Principles of Optics: Contents , 1999 .

[6]  Reginald W. James,et al.  The Optical principles of the diffraction of X-rays , 1948 .

[7]  C. Bowman Accelerator Power Plants , 1994, Science.

[8]  B. L. Henke,et al.  X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92 , 1993 .

[9]  N. Yamamoto,et al.  Development of an Innovative 5 μmφ Focused X-Ray Beam Energy-Dispersive Spectrometer and its Applications : Materials and Device Structures with Atomic Scale Resolution( Solid State Devices and Materials 1) , 1988 .

[10]  P. Beckmann,et al.  The scattering of electromagnetic waves from rough surfaces , 1963 .

[11]  Per Engström,et al.  Microbeam technique for energy‐dispersive x‐ray fluorescence , 1989 .

[12]  G. Vineyard,et al.  Grazing-incidence diffraction and the distorted-wave approximation for the study of surfaces , 1982 .

[13]  D. A. Carpenter,et al.  Improved laboratory X‐ray source for microfluorescence analysis , 1989 .

[14]  J. H. Hubbell,et al.  Atomic form factors, incoherent scattering functions, and photon scattering cross sections , 1975 .

[15]  K Lieberman,et al.  Simple method for focusing x rays using tapered capillaries. , 1988, Applied optics.

[16]  D. Bilderback,et al.  Nanometer spatial resolution achieved in hard x-ray imaging and Laue diffraction experiments. , 1994, Science.

[17]  Mitsuo Shoji,et al.  Theoretical consideration of intensity of an x‐ray microbeam formed by a hollow glass pipe , 1993 .