Uncertainty Estimation of the Dose Rate in Real-Time Applications Using Gaussian Process Regression

Major standard organizations have addressed the issue of reporting uncertainties in dose rate estimations. There are, however, challenges in estimating uncertainties when the radiation environment is considered, especially in real-time dosimetry. This study reports on the implementation of Gaussian process regression based on a spectrum-to-dose conversion operator (i.e., G(E) function), the aim of which is to deal with uncertainty in dose rate estimation based on various irradiation geometries. Results show that the proposed approach provides the dose rate estimation as a probability distribution in a single measurement, thereby increasing its real-time applications. In particular, under various irradiation geometries, the mean values of the dose rate were closer to the true values than the point estimates calculated by a G(E) function obtained from the anterior–posterior irradiation geometry that is intended to provide conservative estimates. In most cases, the 95% confidence intervals of uncertainties included those conservative estimates and the true values over the range of 50–3000 keV. The proposed method, therefore, not only conforms to the concept of operational quantities (i.e., conservative estimates) but also provides more reliable results.

[1]  M. Zaider ICRU, Determination of Dose Equivalents Resulting from External Radiation Sources. , 1989 .

[2]  Jack Valentin,et al.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. , 2007, Annals of the ICRP.

[3]  P. Buzhan,et al.  Silicon Photomultiplier and CsI(Tl) scintillator in application to portable H*(10) dosimeter , 2017, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[4]  S. Tsuda,et al.  Spectrum-dose conversion operator of NaI(Tl) and CsI(Tl) scintillation detectors for air dose rate measurement in contaminated environments. , 2017, Journal of environmental radioactivity.

[5]  M. Zankl,et al.  Calculation of the effective dose and its variation from environmental gamma ray sources. , 1998, Health physics.

[6]  Y. Tanimura,et al.  LaCl3(Ce) scintillation detector applications for environmental gamma-ray measurements of low to high dose rates , 2006 .

[7]  A. Endo,et al.  Operational quantities and new approach by ICRU , 2016, Annals of the ICRP.

[8]  K. Katoh Essentials of the ICRU Report 39: Determination of Dose Equivalents Resulting from External Radiation Sources , 1986 .

[9]  G. Cho,et al.  Parametric optimization for energy calibration and gamma response function of plastic scintillation detectors using a genetic algorithm , 2019, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[10]  R. Casanovas,et al.  Calculation of the ambient dose equivalent H*(10) from gamma-ray spectra obtained with scintillation detectors. , 2016, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[11]  Ping Huang Measurement of air kerma rate and ambient dose equivalent rate using the G(E) function with hemispherical CdZnTe detector , 2018 .

[12]  Wanno Lee,et al.  Feasibility on the spectrometric determination of the individual dose rate for detected gamma nuclides using the dose rate spectroscopy , 2014 .

[13]  A. Camp,et al.  Ambient dose estimation H*(10) from LaBr3(Ce) spectra. , 2014, Radiation protection dosimetry.

[14]  G. Cho,et al.  Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter , 2019 .

[15]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[16]  T. Li,et al.  Precise Monte Carlo simulation of gamma-ray response functions for an NaI(Tl) detector. , 2002, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[17]  M. Katagiri,et al.  Spectrum-to-Exposure Rate Conversion Function of a Ge(Li) in-Situ Environmental Gamma-Ray Spectrometer , 1977, IEEE Transactions on Nuclear Science.

[18]  Andreas Krause,et al.  A tutorial on Gaussian process regression: Modelling, exploring, and exploiting functions , 2016, bioRxiv.

[19]  N Petoussi-Henss,et al.  Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures , 2010, Annals of the ICRP.