Myocardial infarction in rats: high-resolution single-photon emission tomographic imaging with a pinhole collimator

The purpose of this study was to evaluate the accuracy of myocardial imaging by means of high-resolution single-photon emission tomography (SPET) with a pinhole collimator in rats with experimental infarction. Myocardial infarctions were induced in male Wistar rats by ligation of the left coronary artery for 30 min, followed by reperfusion. Two days after the reperfusion, pinhole SPET was performed after the intravenous administration of 111 MBq of thallium-201 chloride, using a rotating gamma camera equipped with a pinhole insert (2.0-mm aperture) in a low-energy pinhole collimator. SPET projection data were collected at 6° increments over 360° using a 4-cm radius of rotation to reconstruct the short- and long-axis images. Projection data were acquired in 15 or 30 s, the SPET imaging being accomplished within 40 min after the injection of201T1. After SPET, the rats were sacrificed to remove the hearts for autoradiography (ARG) and nitroblue tetrazolium (NBT) staining as a visual correlative study. Quantitative correlative studies between pinhole SPET and ARG were performed with linear regression analysis for infarct size and distribution properties (relative counts on SPET images and relative density on autoradiographs) on the short-axis sections. All infarcts (4 mm in minimum diameter) in seven rats were detected by pinhole SPET. The SPET images in rats with or without myocardial infarction were consistent with the findings of ARG and NBT staining. There were significant correlations between pinhole SPET and ARG with respect to the infarct size (r=0.933,P <0.001;n=15) and the relative radiotracer distribution (r=0.931,P <0.001; n=68). This study therefore confirmed the accuracy of myocardial pinhole SPET imaging in rats with myocardial infarction. This method may partially substitute for ARG and prove useful for assessing new myocardial imaging agents in vivo in small laboratory animals.

[1]  A. Carpentier,et al.  The effect of coronary artery reperfusion on the extent of myocardial infarction. , 1977, American heart journal.

[2]  P Wollmer,et al.  Pinhole emission computed tomography: method and experimental evaluation. , 1990, Physics in medicine and biology.

[3]  H. Selye,et al.  Simple Techniques for the Surgical Occlusion of Coronary Vessels in the Rat , 1960, Angiology.

[4]  Y. Yonekura,et al.  Ultra-high resolution SPECT system using four pinhole collimators for small animal studies. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[6]  R Lecomte,et al.  High-resolution PET imaging and quantitation of pharmaceutical biodistributions in a small animal using avalanche photodiode detectors. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  M. Nachlas,et al.  Macroscopic identification of early myocardial infarcts by alterations in dehydrogenase activity. , 1963, The American journal of pathology.

[8]  H. Atkins,et al.  Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  R. Jaszczak,et al.  Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT. , 1994, Physics in medicine and biology.