Grating interferometer based scanning setup for hard X-ray phase contrast imaging.

In x-ray radiography, particularly for technical and industrial applications, a scanning setup is very often favorable when compared to a direct two-dimensional image acquisition. Here, we report on an efficient scanning method for grating based x-ray phase contrast imaging with tube based sources. It uses multiple line detectors for staggered acquisition of the individual phase-stepping images. We find that the total exposure time does not exceed the time needed in an equivalent scanning setup for absorption radiography. Therefore, we conclude that it should be possible to implement the method into a scanning system without affecting the scanning speed or significant increase in cost but with the advantage of providing both the phase contrast and the absorption information at once.

[1]  Wet-etched diffractive lenses for hard X-rays. , 2001, Journal of synchrotron radiation.

[2]  Atsushi Momose,et al.  Phase–contrast X–ray computed tomography for observing biological soft tissues , 1996, Nature Medicine.

[3]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[4]  P. Cloetens,et al.  Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays , 1999 .

[5]  E. Pisano,et al.  Diffraction enhanced x-ray imaging. , 1997, Physics in medicine and biology.

[6]  Jun Li,et al.  Radiography of soft tissue of the foot and ankle with diffraction enhanced imaging , 2004, Journal of the American Podiatric Medical Association.

[7]  Richard J. Fitzgerald,et al.  Phase‐Sensitive X‐Ray Imaging , 2000 .

[8]  U. Bonse,et al.  AN X‐RAY INTERFEROMETER , 1965 .

[9]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[10]  A. Momose Recent Advances in X-ray Phase Imaging , 2005 .

[11]  Jun Li,et al.  Multiple‐image radiography for human soft tissue , 2006, Journal of anatomy.

[12]  O. Bunk,et al.  Neutron phase imaging and tomography. , 2006, Physical review letters.

[13]  S. Wilkins,et al.  Phase-contrast imaging of weakly absorbing materials using hard X-rays , 1995, Nature.

[14]  C. David,et al.  Differential x-ray phase contrast imaging using a shearing interferometer , 2002 .

[15]  R. Dinapoli,et al.  Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting mode , 2001 .

[16]  K. Nugent,et al.  Quantitative Phase Imaging Using Hard X Rays. , 1996, Physical review letters.

[17]  A. Momose Phase-sensitive imaging and phase tomography using X-ray interferometers. , 2003, Optics express.

[18]  S. Wilkins,et al.  X-ray phase-contrast microscopy and microtomography. , 2003, Optics express.

[19]  Atsushi Momose,et al.  Phase Tomography by X-ray Talbot Interferometry for Biological Imaging , 2006 .

[20]  O. Bunk,et al.  Hard x-ray phase tomography with low-brilliance sources. , 2007, Physical review letters.

[21]  Timm Weitkamp,et al.  X-ray wavefront analysis and optics characterization with a grating interferometer , 2005 .

[22]  V. N. Ingal,et al.  X-ray plane-wave topography observation of the phase contrast from a non-crystalline object , 1995 .

[23]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[24]  Jaroslav Sobota,et al.  X-ray dark-field refraction-contrast imaging of micro-objects , 2002 .

[25]  O. Bunk,et al.  A two-directional approach for grating based differential phase contrast imaging using hard x-rays. , 2007, Optics express.