Motion management with phase-adapted 4D-optimization

Cancer treatment with ionizing radiation is often compromised by organ motion, in particular for lung cases. Motion uncertainties can significantly degrade an otherwise optimized treatment plan. We present a spatiotemporal optimization method, which takes into account all phases of breathing via the corresponding 4D-CTs and provides a 4D-optimal plan that can be delivered throughout all breathing phases. Monte Carlo dose calculations are employed to warrant for highest dosimetric accuracy, as pertinent to study motion effects in lung. We demonstrate the performance of this optimization method with clinical lung cancer cases and compare the outcomes to conventional gating techniques. We report significant improvements in target coverage and in healthy tissue sparing at a comparable computational expense. Furthermore, we show that the phase-adapted 4D-optimized plans are robust against irregular breathing, as opposed to gating. This technique has the potential to yield a higher delivery efficiency and a decisively shorter delivery time.

[2]  Melvyn Sim,et al.  Tractable Approximations to Robust Conic Optimization Problems , 2006, Math. Program..

[3]  Barbara Vanderstraeten,et al.  Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations. , 2006, Medical physics.

[4]  Arkadi Nemirovski,et al.  Robust Convex Optimization , 1998, Math. Oper. Res..

[5]  Dimitris Bertsimas,et al.  Nonconvex Robust Optimization for Problems with Constraints , 2010, INFORMS J. Comput..

[6]  D M Shepard,et al.  Direct aperture optimization: a turnkey solution for step-and-shoot IMRT. , 2002, Medical physics.

[7]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[8]  S. Henderson,et al.  Robust optimization for intensity modulated radiation therapy treatment planning under uncertainty , 2005, Physics in medicine and biology.

[9]  M. Goitein Organ and tumor motion: an overview. , 2004, Seminars in radiation oncology.

[10]  Karl Otto,et al.  Direct aperture optimization for IMRT using Monte Carlo generated beamlets. , 2006, Medical physics.

[11]  Timothy C Y Chan,et al.  Accounting for range uncertainties in the optimization of intensity modulated proton therapy , 2007, Physics in medicine and biology.

[12]  Steve B. Jiang,et al.  Temporo-spatial IMRT optimization: concepts, implementation and initial results , 2005, Physics in medicine and biology.

[13]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[14]  Dimitris Bertsimas,et al.  Robust Optimization for Unconstrained Simulation-Based Problems , 2010, Oper. Res..

[15]  P. Keall 4-dimensional computed tomography imaging and treatment planning. , 2004, Seminars in radiation oncology.

[16]  S Webb,et al.  Target-tracking deliveries using conventional multileaf collimators planned with 4D direct-aperture optimization. , 2008, Physics in medicine and biology.

[17]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[18]  Uwe Oelfke,et al.  Acceleration of intensity-modulated radiotherapy dose calculation by importance sampling of the calculation matrices. , 2002, Medical physics.

[19]  R. Jeraj,et al.  Monte Carlo-based inverse treatment planning. , 1999, Physics in medicine and biology.

[20]  John N Tsitsiklis,et al.  A robust approach to IMRT optimization , 2006, Physics in medicine and biology.

[21]  Joao Seco,et al.  Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects. , 2007, Medical physics.

[22]  John N. Tsitsiklis,et al.  Robust Management of Motion Uncertainty in Intensity-Modulated Radiation Therapy , 2008, Oper. Res..

[23]  T. Bortfeld,et al.  Accelerating IMRT optimization by voxel sampling , 2007, Physics in medicine and biology.

[24]  D. Rogers,et al.  EGS4 code system , 1985 .

[25]  Dimitris Bertsimas,et al.  Robust Nonconvex Optimization for Simulation-based Problems , 2007 .

[26]  A. Niemierko Reporting and analyzing dose distributions: a concept of equivalent uniform dose. , 1997, Medical physics.